Factors influencing taper failure of modular revision hip stems

被引:21
|
作者
Krull, A. [1 ]
Morlock, M. M. [1 ]
Bishop, N. E. [2 ]
机构
[1] TUHH Hamburg Univ Technol, Inst Biomech, Denickestr 15, D-21073 Hamburg, Germany
[2] HAW Hamburg Univ Appl Sci, Dept Biomed Engn, Fak Life Sci, Ulmenliet 20, D-21033 Hamburg, Germany
关键词
Hip revision; Taper junction; Fracture; Corrosion; Fatigue; Strength; Titanium; Finite element model; Surface damage; HEAD-NECK TAPER; FRETTING CORROSION; CONTACT FORCES; FEMORAL STEMS; ARTHROPLASTY; FRACTURE; REPLACEMENT; PROSTHESIS; JUNCTION; JOINT;
D O I
10.1016/j.medengphy.2018.02.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Stem modularity of revision hip implant systems offers the advantage of the restoration of individual patient geometry but introduces additional interfaces, which are subjected to repetitive bending loading and have a propensity for fretting corrosion. The male stem taper is the weakest part of the modular junction due to its reduced cross section compared to the outside diameter of the stem. Taper fractures can be the consequence of overloading in combination with corrosion. The purpose of this study was to assess the influence of implant design factors, patient factors, and surgical factors on the risk of taper failure of the modular junction of revision stems. An analytical bending model was used to estimate the strength of the taper connection for pristine, fatigued and corroded conditions. Additionally, a finite element contact model of the taper connection was developed to assess the relative motion and potential for surface damage at the taper interface under physiological loading for varyied assembly and design parameters. Increasing the male taper diameter was shown to be the most effective means for increasing taper strength but would require a concurrent increase in the outer implant diameter to limit a greater risk of total surface damage for a thinner female taper wall. Increasing the assembly force decreases the total surface damage but not local magnitudes, which are probably responsible for crack initiation. It is suggested that in unfavourable loading conditions a monobloc implant system will reduce the risk of failure. (C) 2018 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:65 / 73
页数:9
相关论文
共 50 条
  • [21] Dual-Modular Versus Single-Modular Stems for Primary Total Hip Arthroplasty: A Long-Term Survival Analysis
    Fokter, Samo K.
    Noc, Nejc
    Levasic, Vesna
    Hanc, Marko
    Zajc, Jan
    MEDICINA-LITHUANIA, 2023, 59 (02):
  • [22] Risk Factors for Subsidence of Modular Fluted Tapered Stems Used During Revision Total Hip Arthroplasty for Periprosthetic Hip Fractures
    Parry, Joshua A.
    Hernandez, Nicolas M.
    Berry, Daniel J.
    Abdel, Matthew P.
    Yuan, Brandon J.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (09): : 2967 - 2970
  • [23] Managing femoral bone loss in revision total hip replacement FLUTED TAPERED MODULAR STEMS
    Cross, M. B.
    Paprosky, W. G.
    BONE & JOINT JOURNAL, 2013, 95B (11): : 95 - 97
  • [24] Indications, complications and outcomes of modular stems in total hip revision arthroplasty: a systematic review of the literature
    Cottino, Umberto
    Pirato, Francesco
    Battaglia, Domenico L.
    Dettoni, Federico
    Bruzzone, Matteo
    Rossi, Roberto
    MINERVA ORTHOPEDICS, 2024, 75 (03): : 243 - 254
  • [25] Non-modular tapered fluted titanium stems in hip revision surgery GAINING ATTENTION
    Konan, S.
    Garbuz, D. S.
    Masri, B. A.
    Duncan, C. P.
    BONE & JOINT JOURNAL, 2014, 96B : 56 - 59
  • [26] Corrosion and Fretting of a Modular Hip System: A Retrieval Analysis of 60 Rejuvenate Stems
    De Martino, Ivan
    Assini, Joseph B.
    Elpers, Marcella E.
    Wright, Timothy M.
    Westrich, Geoffrey H.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (08): : 1470 - 1475
  • [27] Systematic review of primary total hip arthroplasty using titanium-titanium modular-neck prostheses: the true risk of revision
    Lex, Johnathan R.
    Welch, Matthew D.
    See, Abbas
    Edwards, Thomas C.
    Stavropoulos, Nikolaos A.
    Babis, George C.
    HIP INTERNATIONAL, 2021, 31 (03) : 295 - 303
  • [28] Titanium modular stems in total hip arthroplasty due to developmental dysplasia: a registry comparison with single-taper implants
    Castagnini, Francesco
    Cosentino, Monica
    Bordini, Barbara
    Montalti, Maurizio
    Biondi, Federico
    Faldini, Cesare
    Traina, Francesco
    HIP INTERNATIONAL, 2023, 33 (05) : 916 - 924
  • [29] Mid-term outcomes of titanium modular neck femoral stems in revision total hip arthroplasty
    Ouanezar, Herve
    Jalaguier, Thomas
    Franck, Florent
    Pibarot, Vincent
    Bothorel, Hugo
    Saffarini, Mo
    Piton, Jean-Pierre
    ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7 (05)
  • [30] What Is the Difference Between Modular and Nonmodular Tapered Fluted Titanium Stems in Revision Total Hip Arthroplasty
    Huang, Yong
    Zhou, Yixin
    Shao, Hongyi
    Gu, Jianming
    Tang, Hao
    Tang, Qiheng
    JOURNAL OF ARTHROPLASTY, 2017, 32 (10): : 3108 - 3113