Reliability of the Inverse Water Volumetry Method to Measure the Volume of the Upper Limb

被引:13
作者
Beek, Martinus A. [1 ]
te Slaa, Alexander [1 ]
van der Laan, Lijckle [1 ]
Mulder, Paul G. H. [2 ]
Rutten, Harm J. T. [3 ]
Voogd, Adri C. [4 ,5 ]
Luiten, Ernest J. T. [1 ]
Gobardhan, Paul D. [1 ]
机构
[1] Amphia Hosp, Dept Surg, NL-4818 CK Breda, Netherlands
[2] Amphia Hosp, Amphia Acad, NL-4818 CK Breda, Netherlands
[3] Maastricht Univ, Dept Surg, Fac Hlth Med & Life Sci, Res Inst Growth & Dev GROW, NL-6200 MD Maastricht, Netherlands
[4] Maastricht Univ, Dept Epidemiol, Fac Hlth Med & Life Sci, Res Inst Growth & Dev GROW, NL-6200 MD Maastricht, Netherlands
[5] Comprehens Canc Ctr Netherlands, Res Dept, Eindhoven, Netherlands
关键词
SENTINEL NODE BIOPSY; BREAST-CANCER PATIENTS; QUALITY-OF-LIFE; LYMPH-NODE; AXILLARY DISSECTION; UPPER EXTREMITY; MORBIDITY; ARM; DISPLACEMENT; SURGERY;
D O I
10.1089/lrb.2015.0011
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Lymphedema of the upper extremity is a common side effect of lymph node dissection or irradiation of the axilla. Several techniques are being applied in order to examine the presence and severity of lymphedema. Measurement of circumference of the upper extremity is most frequently performed. An alternative is the water-displacement method. The aim of this study was to determine the reliability and the reproducibility of the Inverse Water Volumetry apparatus (IWV-apparatus) for the measurement of arm volumes. Patients and Methods: The IWV-apparatus is based on the water-displacement method. Measurements were performed by three breast cancer nurse practitioners on ten healthy volunteers in three weekly sessions. Results: The intra-class correlation coefficient, defined as the ratio of the subject component to the total variance, equaled 0.99. The reliability index is calculated as 0.14kg. This indicates that only changes in a patient's arm volume measurement of more than 0.14kg would represent a true change in arm volume, which is about 6% of the mean arm volume of 2.3kg. Conclusion: The IWV-apparatus proved to be a reliable and reproducible method to measure arm volume.
引用
收藏
页码:126 / 130
页数:5
相关论文
共 30 条
[1]  
Armer Jane M., 2005, Lymphatic Research and Biology, V3, P208, DOI 10.1089/lrb.2005.3.208
[2]   Subjective morbidity and quality of life after sentinel node biopsy and axillary lymph node dissection for breast cancer [J].
Barranger, E ;
Dubernard, G ;
Fleurence, J ;
Antoine, M ;
Darai, E ;
Uzan, S .
JOURNAL OF SURGICAL ONCOLOGY, 2005, 92 (01) :17-22
[3]   Relapse and morbidity in patients undergoing sentinel lymph node biopsy alone or with axillary dissection for breast cancer [J].
Blanchard, DK ;
Donohue, JH ;
Reynolds, C ;
Grant, CS .
ARCHIVES OF SURGERY, 2003, 138 (05) :482-487
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Standardised measurements used to order compression garments can be used to calculate arm volumes to evaluate lymphoedema treatment [J].
Brorson, Hakan ;
Hoijer, Patrik .
JOURNAL OF PLASTIC SURGERY AND HAND SURGERY, 2012, 46 (06) :410-415
[6]   A Morbidity Screening Tool for identifying fatigue, pain, upper limb dysfunction and lymphedema after breast cancer treatment: A validity study [J].
Bulley, Catherine ;
Coutts, Fiona ;
Blyth, Christine ;
Jack, Wilma ;
Chetty, Udi ;
Barber, Matthew ;
Tan, Chee Wee .
EUROPEAN JOURNAL OF ONCOLOGY NURSING, 2014, 18 (02) :218-227
[7]   Validation of the inverse water volumetry method: a new gold standard for arm volume measurements [J].
Damstra, Robert J. ;
Glazenburg, Eltjo J. ;
Hop, Wim C. J. .
BREAST CANCER RESEARCH AND TREATMENT, 2006, 99 (03) :267-273
[8]   Assessment of Volume Measurement of Breast Cancer-Related Lymphedema by Three Methods: Circumference Measurement, Water Displacement, and Dual Energy X-Ray Absorptiometry [J].
Gjorup, Caroline ;
Zerahn, Bo ;
Hendel, Helle W. .
LYMPHATIC RESEARCH AND BIOLOGY, 2010, 8 (02) :111-119
[9]   Morbidity of breast cancer patients following complete axillary dissection or sentinel node biopsy only:: A comparative evaluation [J].
Haid, A ;
Köberle-Wührer, R ;
Knauer, M ;
Burtscher, J ;
Fritzsche, H ;
Peschina, W ;
Jasarevic, Z ;
Ammann, M ;
Hergan, K ;
Sturn, H ;
Zimmermann, G .
BREAST CANCER RESEARCH AND TREATMENT, 2002, 73 (01) :31-36
[10]  
Herpertz U., 1994, Zeitschrift fuer Lymphologie, V18, P24