Effects of heat flux, mass flux, vapor quality, and saturation temperature on flow boiling heat transfer in microchannels
被引:141
|
作者:
Bertsch, Stefan S.
论文数: 0引用数: 0
h-index: 0
机构:
Purdue Univ, Sch Mech Engn, Cooling Technol Res Ctr, W Lafayette, IN 47907 USA
Purdue Univ, Sch Mech Engn, Ray W Herrick Labs, W Lafayette, IN 47907 USAPurdue Univ, Sch Mech Engn, Cooling Technol Res Ctr, W Lafayette, IN 47907 USA
Bertsch, Stefan S.
[1
,2
]
Groll, Eckhard A.
论文数: 0引用数: 0
h-index: 0
机构:
Purdue Univ, Sch Mech Engn, Cooling Technol Res Ctr, W Lafayette, IN 47907 USA
Purdue Univ, Sch Mech Engn, Ray W Herrick Labs, W Lafayette, IN 47907 USAPurdue Univ, Sch Mech Engn, Cooling Technol Res Ctr, W Lafayette, IN 47907 USA
Groll, Eckhard A.
[1
,2
]
Garimella, Suresh V.
论文数: 0引用数: 0
h-index: 0
机构:
Purdue Univ, Sch Mech Engn, Cooling Technol Res Ctr, W Lafayette, IN 47907 USAPurdue Univ, Sch Mech Engn, Cooling Technol Res Ctr, W Lafayette, IN 47907 USA
Garimella, Suresh V.
[1
]
机构:
[1] Purdue Univ, Sch Mech Engn, Cooling Technol Res Ctr, W Lafayette, IN 47907 USA
[2] Purdue Univ, Sch Mech Engn, Ray W Herrick Labs, W Lafayette, IN 47907 USA
Flow boiling heat transfer with the refrigerants R-134a and R-245fa in copper microchannel cold plate evaporators is investigated. Arrays of microchannels of hydraulic diameter 1.09 and 0.54 mm are considered. The aspect ratio of the rectangular cross section of the channels in both test sections is 2.5. The heat transfer coefficient is measured as a function of local thermodynamic vapor quality in the range -0.2 to 0.9, at saturation temperatures ranging from 8 to 30 degrees C, mass flux from 20 to 350 kg m(-2) s(-1), and heat flux from 0 to 22 W cm(-2). The heat transfer coefficient is found to vary significantly with heat flux and vapor quality, but only slightly with saturation pressure and mass flux for the range of values investigated. It was found that nucleate boiling dominates the heat transfer. In addition to discussing measurement results, several flow boiling heat transfer correlations are also assessed for applicability to the present experiments. (C) 2008 Elsevier Ltd. All rights reserved.
机构:
Zhejiang Univ, Dept Energy Engn, 38 Zheda Rd, Hangzhou 310027, Zhejiang, Peoples R ChinaZhejiang Univ, Dept Energy Engn, 38 Zheda Rd, Hangzhou 310027, Zhejiang, Peoples R China
Li, Wei
Zhou, Kan
论文数: 0引用数: 0
h-index: 0
机构:
Zhejiang Univ, Dept Energy Engn, 38 Zheda Rd, Hangzhou 310027, Zhejiang, Peoples R ChinaZhejiang Univ, Dept Energy Engn, 38 Zheda Rd, Hangzhou 310027, Zhejiang, Peoples R China
Zhou, Kan
Li, Junye
论文数: 0引用数: 0
h-index: 0
机构:
Zhejiang Univ, Dept Energy Engn, 38 Zheda Rd, Hangzhou 310027, Zhejiang, Peoples R China
Zhejiang Univ, Dept Energy Engn, Coinnovat Ctr Adv Aeroengine, Hangzhou 310027, Zhejiang, Peoples R ChinaZhejiang Univ, Dept Energy Engn, 38 Zheda Rd, Hangzhou 310027, Zhejiang, Peoples R China
Li, Junye
Feng, Zhaozan
论文数: 0引用数: 0
h-index: 0
机构:
CRRC Zhuzhou Inst Co, 169 Shi Dai Rd, Shifehg Dist 412000, Zhuzhou, Peoples R ChinaZhejiang Univ, Dept Energy Engn, 38 Zheda Rd, Hangzhou 310027, Zhejiang, Peoples R China
Feng, Zhaozan
Zhu, Hua
论文数: 0引用数: 0
h-index: 0
机构:
Zhejiang Univ, Dept Energy Engn, 38 Zheda Rd, Hangzhou 310027, Zhejiang, Peoples R ChinaZhejiang Univ, Dept Energy Engn, 38 Zheda Rd, Hangzhou 310027, Zhejiang, Peoples R China