Pre-concentration procedure for determination of copper and zinc in food samples by sequential multi-element flame atomic absorption spectrometry

被引:72
|
作者
Ferreira, Hadla S. [1 ]
Santos, Ana C. N. [1 ]
Portugal, Lindomar A. [1 ]
Costa, Antonio C. S. [1 ]
Miro, Manuel [2 ]
Ferreira, Sergio L. C. [1 ]
机构
[1] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[2] Univ Balearic Isl, Fac Sci, Dept Chem, E-07122 Palma de Mallorca, Spain
关键词
Zinc; Copper; Food samples; Cloud point; Box-Behnken design;
D O I
10.1016/j.talanta.2008.05.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper is proposed a simultaneous pre-concentration procedure using cloud point extraction for the determination of copper and zinc in food samples employing sequential multi-element flame atomic absorption spectrometry (FS-FAAS). The reagent used is 1-(2-pyridylazo)-2-naphthol (PAN) and the micellar phase is obtained using the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114) and centrifugation. The optimization step was performed using Box-Behnken design for three factors: solution pH, reagent concentration and buffer concentration. A multiple response function was established in order to get an experimental condition for simultaneous extraction of copper and zinc. Under the optimized experimental conditions, the method allows the determination of copper with a limit of detection (3 sigma(b)/S, LOD) of 0.1 mu gL(-1), precision expressed as relative standard deviation (R.S.D.) of 2.1 and 1.3% (N=10), for copper concentrations of 10 and 50 wg L-1, respectively. Zinc is determined with a LOD of 0.15 mu g L-1 and precision as R.S.D. of 2.7 and 1.7% for concentrations of 10 and 50 wg L-1, respectively. The enhancement factors obtained were 36 and 32 for copper and zinc, respectively. The accuracy was assessed by analysis of certified reference materials, namely. SRM 1567a - Wheat Flour and SRM 8433 - Corn Bran from National Institute of Standards & Technology and BCR 189-wholemeal flour from Institute of Reference Materials and Measurements. The method was applied to the determination of copper and zinc in oats, powdered chocolate, corn flour and wheat flour samples. The copper content in the samples analyzed varied from 1.14 to 3.28 mu g g(-1) and zinc from 8.7 to 22.9 mu g g(-1). (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:73 / 76
页数:4
相关论文
共 50 条
  • [41] Determination of Trace Copper(II) in Food Samples by Flame Atomic Absorption Spectrometry After Cloud Point Extraction
    Xiang Guoqiang
    Wen Shengping
    Jiang Xiuming
    Liu Xing
    He Lijun
    IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2011, 30 (03): : 101 - 107
  • [42] Determination of iron and copper in food samples by flow injection cloud point extraction flame atomic absorption spectrometry
    Durukan, Ilknur
    Sahin, Cigdem Arpa
    Satiroglu, Nuray
    Bektas, Sema
    MICROCHEMICAL JOURNAL, 2011, 99 (01) : 159 - 163
  • [43] Determination of trace elements in leach solution by flame atomic absorption spectrometry after pre-concentration on Amberlite XAD-4
    Bingol, D.
    Akcay, M.
    ASIAN JOURNAL OF CHEMISTRY, 2008, 20 (05) : 4031 - 4036
  • [44] ATOMIC-ABSORPTION SPECTROMETRY OF SELENIUM IN AN ARGON-HYDROGEN FLAME AFTER ELECTROCHEMICAL PRE-CONCENTRATION
    HOLEN, B
    BYE, R
    LUND, W
    ANALYTICA CHIMICA ACTA, 1981, 130 (02) : 257 - 265
  • [45] On-line determination of the trace amount of cobalt(II) in real samples by flame atomic absorption spectrometry method after pre-concentration by modified polyvinyl chloride
    Tahere Zarnoushe Farahani
    Ghadamali Bagherian
    Mansour Arab Chamjangali
    Motahare Ashrafi
    SN Applied Sciences, 2023, 5
  • [46] On-line determination of the trace amount of cobalt(II) in real samples by flame atomic absorption spectrometry method after pre-concentration by modified polyvinyl chloride
    Farahani, Tahere Zarnoushe
    Bagherian, Ghadamali
    Chamjangali, Mansour Arab
    Ashrafi, Motahare
    SN APPLIED SCIENCES, 2023, 5 (07):
  • [47] Solid sampling analysis by flame atomic absorption spectrometry for lead determination in seawater samples after pre-concentration using cocrystallized alizarin red-naphthalene
    Korn, MDA
    Bispo, MRS
    Korn, M
    da Costa, AB
    de Mattos, JCP
    Paniz, JNG
    Flores, EMD
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2005, 16 (6A) : 1241 - 1247
  • [48] A new ultrasonic-assisted cloud-point-extraction procedure for pre-concentration and determination of ultra-trace levels of copper in selected beverages and foods by flame atomic absorption spectrometry
    Altunay, Nail
    Gurkan, Ramazan
    Orhan, Ulas
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2015, 32 (09): : 1475 - 1487
  • [49] Application of Nb2O5–SiO2 in Pre-Concentration and Determination of Copper and Cadmium by Flow System with Flame Atomic Absorption Spectrometry
    Dilma Budziak
    Edson Luiz da Silva
    Silvia Denofre de Campos
    Eduardo Carasek
    Microchimica Acta, 2003, 141 : 169 - 174
  • [50] Cloud point extraction for the determination of copper in environmental samples by flame atomic absorption spectrometry
    Shokrollahi, Ardeshir
    Ghaedi, Mehrorang
    Gharaghani, Shiva
    Fathi, Mohammad Reza
    Soylak, Mustafa
    QUIMICA NOVA, 2008, 31 (01): : 70 - 74