Pre-concentration procedure for determination of copper and zinc in food samples by sequential multi-element flame atomic absorption spectrometry

被引:72
|
作者
Ferreira, Hadla S. [1 ]
Santos, Ana C. N. [1 ]
Portugal, Lindomar A. [1 ]
Costa, Antonio C. S. [1 ]
Miro, Manuel [2 ]
Ferreira, Sergio L. C. [1 ]
机构
[1] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[2] Univ Balearic Isl, Fac Sci, Dept Chem, E-07122 Palma de Mallorca, Spain
关键词
Zinc; Copper; Food samples; Cloud point; Box-Behnken design;
D O I
10.1016/j.talanta.2008.05.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper is proposed a simultaneous pre-concentration procedure using cloud point extraction for the determination of copper and zinc in food samples employing sequential multi-element flame atomic absorption spectrometry (FS-FAAS). The reagent used is 1-(2-pyridylazo)-2-naphthol (PAN) and the micellar phase is obtained using the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114) and centrifugation. The optimization step was performed using Box-Behnken design for three factors: solution pH, reagent concentration and buffer concentration. A multiple response function was established in order to get an experimental condition for simultaneous extraction of copper and zinc. Under the optimized experimental conditions, the method allows the determination of copper with a limit of detection (3 sigma(b)/S, LOD) of 0.1 mu gL(-1), precision expressed as relative standard deviation (R.S.D.) of 2.1 and 1.3% (N=10), for copper concentrations of 10 and 50 wg L-1, respectively. Zinc is determined with a LOD of 0.15 mu g L-1 and precision as R.S.D. of 2.7 and 1.7% for concentrations of 10 and 50 wg L-1, respectively. The enhancement factors obtained were 36 and 32 for copper and zinc, respectively. The accuracy was assessed by analysis of certified reference materials, namely. SRM 1567a - Wheat Flour and SRM 8433 - Corn Bran from National Institute of Standards & Technology and BCR 189-wholemeal flour from Institute of Reference Materials and Measurements. The method was applied to the determination of copper and zinc in oats, powdered chocolate, corn flour and wheat flour samples. The copper content in the samples analyzed varied from 1.14 to 3.28 mu g g(-1) and zinc from 8.7 to 22.9 mu g g(-1). (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:73 / 76
页数:4
相关论文
共 50 条
  • [31] Determination of Lead Content in Medicinal Plants by Pre-concentration Flow Injection Analysis-Flame Atomic Absorption Spectrometry
    Campos, Marina M. A.
    Tonuci, Henry
    Silva, Silvana M.
    Altoe, Bruna de S.
    de Carvalho, Dermeval
    Kronka, Eloisa A. M.
    Pereira, Ana M. S.
    Bertoni, Bianca W.
    Franca, Suzelei de C.
    Miranda, Carlos E. S.
    PHYTOCHEMICAL ANALYSIS, 2009, 20 (06) : 445 - 449
  • [32] Solid phase extraction and sequential elution for pre-concentration of traces of Mn and Zn in analysis of honey by flame atomic absorption spectrometry
    Pohl, Pawel
    Stecka, Helena
    Jamroz, Piotr
    ANALYTICAL METHODS, 2012, 4 (01) : 125 - 131
  • [33] Determination of zinc in aerosol samples by discrete nebulization flame atomic absorption spectrometry
    Sarica, DY
    Akim, D
    Özden, T
    TURKISH JOURNAL OF CHEMISTRY, 2002, 26 (02): : 263 - 270
  • [34] Multi-element determination of Pt, Pd and Ir traces in environmental samples by ICP-MS after pre-concentration
    Alonso Castillo, Manuel L.
    Garcia de Torres, Amparo
    Vereda Alonso, Elisa
    Siles Cordero, Ma Teresa
    Cano Pavon, Jose Manuel
    TALANTA, 2012, 99 : 853 - 858
  • [35] Use of High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS) for Sequential Multi-Element Determination of Metals in Seawater and Wastewater Samples
    Pena-Vazquez, E.
    Barciela-Alonso, M. C.
    Pita-Calvo, C.
    Dominguez-Gonzalez, R.
    Bermejo-Barrera, P.
    JOURNAL OF APPLIED SPECTROSCOPY, 2015, 82 (04) : 681 - 686
  • [36] Use of High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS) for Sequential Multi-Element Determination of Metals in Seawater and Wastewater Samples
    E. Peña-Vázquez
    M. C. Barciela-Alonso
    C. Pita-Calvo
    R. Domínguez-González
    P. Bermejo-Barrera
    Journal of Applied Spectroscopy, 2015, 82 : 681 - 686
  • [37] A Simple Pre-concentration Method for the Determination of Nickel(II) in Urine Samples Using UV-Vis Spectrophotometry and Flame Atomic Absorption Spectrometry Techniques
    Khudhair, Ahmed Fadhil
    Hassan, Mouyed Khudhair
    Alesary, Hasan F.
    Abbas, Ahmed S.
    INDONESIAN JOURNAL OF CHEMISTRY, 2019, 19 (03) : 638 - 649
  • [38] Determination of copper, magnesium and zinc in mononuclear leukocytes by flame atomic absorption spectrometry
    Rahn-Chique, Kareem
    Carrion, Nereida
    Murillo, Miguel
    INVESTIGACION CLINICA, 2012, 53 (04): : 342 - 352
  • [39] Application of Nb2O5-SiO2 in pre-concentration and determination of copper and cadmium by flow system with flame atomic absorption spectrometry
    Budziak, D
    da Silva, EL
    de Campos, SD
    Carasek, E
    MICROCHIMICA ACTA, 2003, 141 (3-4) : 169 - 174
  • [40] Determination of Lead by Flame Atomic Absorption Spectrometry after Pre-concentration using Silica Gel Coated with Schiff's Bases
    Bader, Nabil
    Kuss, Heinz-Martin
    Telgheder, Ursula
    Alshelmani, Nessma
    MOROCCAN JOURNAL OF CHEMISTRY, 2018, 6 (02): : 354 - 358