Conservative management of infected pacemaker and implantable defibrillator sites with a closed antimicrobial irrigation system

被引:20
作者
Lopez, J. Alberto [1 ,2 ]
机构
[1] St Lukes Episcopal Hosp, Texas Heart Inst, Dept Cardiol & Electrophysiol, Houston, TX USA
[2] Baylor Coll Med, Dept Med, Houston, TX 77030 USA
来源
EUROPACE | 2013年 / 15卷 / 04期
关键词
Infection; Pacemakers; Cardiac rhythm management devices; Cardiac arrhythmias; LEAD EXTRACTION; SUCTION IRRIGATION; CENTER EXPERIENCE; TRENDS;
D O I
10.1093/europace/eus317
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Current guidelines recommend that patients with infected cardiac rhythm management device (CRMD) sites undergo removal of all system components (pulse-generator and leads). However, lead removal may not be an option for patients who lack access to state-of-the-art technology, lack the necessary financial resources, or are at very high risk because of age or concomitant disease. In this case series, we report our successful experience with conservative treatment of five such patients, who had CRMD infections localized to the device pocket. The device pocket and remaining hardware were completely sterilized to successfully eradicate the infection. First, all non-viable tissue, chronically inflamed tissue, granulation tissue, and scar tissue were completely removed, with special attention to complete haemostasis. Secondly, all non-essential foreign materials, including old sutures and plastic suture anchoring sleeves, were removed, and the remaining hardware was completely sterilized. To achieve this goal, we used mechanical means (scrubbing and pulsed lavage), as well as a closed antimicrobial irrigation system. In all five cases, the pulse-generator site was saved, lead removal was avoided, and the patients were free of local or systemic infection for a minimum of 1 year after treatment. Our conservative approach to the management of infected CRMD sites is feasible and beneficial in selected patients who are at very high risk for lead removal or who lack access to the technology necessary for safe performance of this procedure, provided that the infection is limited to the implant site.
引用
收藏
页码:541 / 545
页数:5
相关论文
共 19 条
[1]   Trends, indications and outcomes of cardiac implantable device system extraction: a single UK centre experience over the last decade [J].
Arujuna, A. ;
Williams, S. ;
Whittaker, J. ;
Shetty, A. ;
Roy, D. ;
Bostock, J. ;
Kirubakaran, S. ;
O'Neill, M. ;
Gill, J. ;
Cooklin, M. ;
Patel, N. ;
Blauth, C. ;
Bucknall, C. ;
Hamid, S. ;
Rinaldi, C. A. .
INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2012, 66 (02) :218-225
[2]   Lead extraction for device related infections: a single-centre experience [J].
Bracke, FALE ;
Meijer, A ;
van Gelder, LM .
EUROPACE, 2004, 6 (03) :243-247
[3]   Closed double-lumen suction irrigation in the management of chronic diaphyseal osteomyelitis LONG-TERM FOLLOW-UP [J].
Caesar, B. C. ;
Morgan-Jones, R. L. ;
Warren, R. E. ;
Wade, R. H. ;
Roberts, P. J. ;
Richardson, J. B. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (09) :1243-1248
[4]   Current concepts - Treatment of infections associated with surgical implants [J].
Darouiche, RO .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (14) :1422-1429
[5]  
Furman R W, 1972, Ann Thorac Surg, V14, P54
[6]   16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United States 1993 to 2008 [J].
Greenspon, Arnold J. ;
Patel, Jasmine D. ;
Lau, Edmund ;
Ochoa, Jorge A. ;
Frisch, Daniel R. ;
Ho, Reginald T. ;
Pavri, Behzad B. ;
Kurtz, Steven M. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (10) :1001-1006
[7]   Bacterial biofilms: From the natural environment to infectious diseases [J].
Hall-Stoodley, L ;
Costerton, JW ;
Stoodley, P .
NATURE REVIEWS MICROBIOLOGY, 2004, 2 (02) :95-108
[8]   PACEMAKER INFECTIONS - TREATMENT WITH TOTAL OR PARTIAL PACEMAKER SYSTEM REMOVAL [J].
HARJULA, A ;
JARVINEN, A ;
VIRTANEN, KS ;
MATTILA, S .
THORACIC AND CARDIOVASCULAR SURGEON, 1985, 33 (04) :218-220
[9]   Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction [J].
Hauser, Robert G. ;
Katsiyiannis, William T. ;
Gornick, Charles C. ;
Almquist, Adrian K. ;
Kallinen, Linda M. .
EUROPACE, 2010, 12 (03) :395-401
[10]   THE SALVAGE OF INFECTED CARDIAC-PACEMAKER POCKETS USING A CLOSED IRRIGATION SYSTEM [J].
HURST, LN ;
EVANS, HB ;
WINDLE, B ;
KLEIN, GJ .