Predictive Value of Corneal Topography for ClearKone Hybrid Contact Lenses

被引:10
作者
Downie, Laura E. [1 ]
机构
[1] Univ Melbourne, Dept Optometry & Vis Sci, Parkville, Vic 3010, Australia
关键词
contact lens; keratoconus; pellucid marginal degeneration; hybrid; rigid gas permeable; RGP; cornea; corneal sagittal height; corneal topography; tangential map; corneal irregularity; post-LASIK ectasia; KERATOCONUS; PERFORMANCE; SYNERGEYES;
D O I
10.1097/OPX.0b013e318297da25
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The purpose of this study was to evaluate the predictive value of corneal topography data for fitting ClearKone hybrid contact lenses on eyes with corneal ectasia. Methods. Ophthalmic records from eyes with established corneal ectasia that had been successfully fitted with SynergEyes ClearKone lenses (n = 73) were retrospectively reviewed. Correlations between corneal parameters (simulated steep and flat keratometry values, average corneal sagittal height, inferior-superior index for keratoconus, corneal eccentricity, cone displacement, and cone diameter) and ClearKone lens parameters (vault and skirt curvature) were analyzed. Results. Two topographical correlates to ClearKone lens parameters were identified. Mean weighted corneal sagittal height at a 7.4-mm chord was strongly predictive of the optimal ClearKone lens vault; a linear relationship was observed between these parameters (R-2 = 0.96). More significant vertical decentration of the corneal apex was found to be associated with the need for a steeper lens skirt curvature (p < 0.05). Conclusions. This study demonstrates that baseline corneal topography-derived data are valuable for predicting lens parameters for an optimally fit SynergEyes ClearKone hybrid contact lens.
引用
收藏
页码:E191 / E197
页数:7
相关论文
共 23 条
[1]   SynergEyes Lenses for Keratoconus [J].
Abdalla, Yasmine F. ;
Elsahn, Ahmad F. ;
Hammersmith, Kristin M. ;
Cohen, Elisabeth J. .
CORNEA, 2010, 29 (01) :5-8
[2]  
Asbell PA, 1997, CORNEA DIAGNOSIS MAN, P1457
[3]  
Bufidis Theodore, 1998, CLAO Journal, V24, P206
[4]   The performance of four different corneal topographers on normal human corneas and its impact on orthokeratology lens fitting [J].
Cho, P ;
Lam, AKC ;
Mountford, J ;
Ng, L .
OPTOMETRY AND VISION SCIENCE, 2002, 79 (03) :175-183
[5]  
Donshik P C, 1996, Trans Am Ophthalmol Soc, V94, P135
[6]   Rigid contact lens fitting relationships in keratoconus [J].
Edrington, TB ;
Szczotka, LB ;
Barr, JT ;
Achtenberg, JF ;
Burger, DS ;
Janoff, AM ;
Olafsson, HE ;
Chun, MW ;
Boyle, JW ;
Gordon, MO ;
Zadnik, K .
OPTOMETRY AND VISION SCIENCE, 1999, 76 (10) :692-699
[7]   Standardized rigid contact lens fitting protocol for keratoconus [J].
Edrington, TB ;
Barr, JT ;
Zadnik, K ;
Davis, LJ ;
Gundel, RE ;
Libassi, DP ;
McMahon, TT ;
Gordon, MO .
OPTOMETRY AND VISION SCIENCE, 1996, 73 (06) :369-375
[8]   Topographic analysis in pellucid marginal corneal degeneration and keratoglobus [J].
Karabatsas, CH ;
Cook, D .
EYE, 1996, 10 :451-455
[9]   KERATOCONUS AND RELATED NONINFLAMMATORY CORNEAL THINNING DISORDERS [J].
KRACHMER, JH ;
FEDER, RS ;
BELIN, MW .
SURVEY OF OPHTHALMOLOGY, 1984, 28 (04) :293-322
[10]   CLINICAL MANAGEMENT OF KERATOCONUS - A MULTICENTER ANALYSIS [J].
LASS, JH ;
LEMBACH, RG ;
PARK, SB ;
HOM, DL ;
FRITZ, ME ;
SVILAR, GM ;
NUAMAH, IF ;
REINHART, WJ ;
STOCKER, EG ;
KEATES, RH ;
MORAN, CT ;
COBO, LM ;
FOULKS, GN .
OPHTHALMOLOGY, 1990, 97 (04) :433-445