Performance of a photostimulable storage phosphor digital system with or without the sharpen filter and cone beam CT for detecting approximal enamel subsurface demineralization

被引:12
作者
Belem, M. D. F. [1 ]
Tabchoury, C. P. M. [1 ]
Ferreira-Santos, R. I. [2 ]
Groppo, F. C. [1 ]
Haiter-Neto, F. [1 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Piracicaba, SP, Brazil
[2] Univ Sao Paulo, UNICID, Dept Pediat Dent & Orthodont, Sao Paulo, Brazil
关键词
tooth demineralization; diagnosis; cone beam CT; digital radiography; COMPUTED-TOMOGRAPHY; PROXIMAL CARIES; DIAGNOSTIC-ACCURACY; SPATIAL-RESOLUTION; VISTASCAN SYSTEM; FILM RADIOGRAPHY; LESIONS; ENHANCEMENT; DEPTH; MODALITIES;
D O I
10.1259/dmfr.20120313
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to assess the performance of photostimulable storage phosphor (PSP) radiographs with or without using the sharpen filter and cone beam CT (CBCT) for detecting enamel subsurface demineralization. Methods: Enamel subsurface demineralization was induced on one of the approximal surfaces of 120 sound human teeth. Standardized images of all teeth were acquired after the demineralization phase using the Digora (R) Optime (Orion Corp./Soredex, Helsinki, Finland) (PSP) and the i-CAT (TM) (Imaging Sciences International, Hatfield, PA) (CBCT) systems. Three calibrated observers interpreted the images using a five-point scale (1, demineralization definitely absent; 2, demineralization probably absent; 3, unsure; 4, demineralization probably present; and 5, demineralization definitely present). Diagnoses were validated by cross-sectional microhardness profiling in the test areas of the approximal surfaces. Interobserver agreement was analysed using kappa statistics. Accuracy was estimated by the areas under the receiver operating characteristic curves (4,), which were compared using the Kruskal Wallis test (alpha = 5%). Results: Interobserver agreement was higher for CBCT (kappa = 0.7-0.8), followed by sharpen-filtered (kappa = 0.6-0.7) and original (kappa = 0.5-0.6) images. CBCT presented the highest accuracy value (A(z) = 0.897) compared with the original (A(z) = 0.792) and sharpen-filtered (A(z) = 0.712) images. However, no statistical differences were observed between the imaging modalities (p = 0.0794). Conclusions: It can be concluded that PSP radiographs with or without using the sharpen filter and the CBCT images may be useful adjuncts for detecting subtle approximal enamel demineralization.
引用
收藏
页数:9
相关论文
共 35 条
[11]   Linear and logarithmic subtraction for detecting enamel subsurface demineralization [J].
Haiter-Neto, F ;
Ferreira, RI ;
Tabchoury, CPM ;
Bóscolo, F .
DENTOMAXILLOFACIAL RADIOLOGY, 2005, 34 (03) :133-139
[12]   Task-specific enhancement filters in storage phosphor images from the Vistascan system for detection of proximal caries lesions of known size [J].
Haiter-Neto, Francisco ;
Casanova, Marcia Spinelli ;
Frydenberg, Morten ;
Wenzel, Ann .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (01) :116-121
[13]  
Hala LA., 2006, Braz. J. Oral Sci, V5, P1012, DOI [10.20396/BJOS.V5I17.8641887, DOI 10.20396/BJOS.V5I17.8641887]
[14]   Effect of monitor display on detection of approximal caries lesions in digital radiographs [J].
Isidor, S. ;
Faaborg-Andersen, M. ;
Hintze, H. ;
Kirkevang, L-L ;
Frydenberg, M. ;
Haiter-Neto, F. ;
Wenzel, A. .
DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (08) :537-541
[15]   Relationship between histological and radiographic caries lesion depth measured in images from four digital radiography systems [J].
Jacobsen, JH ;
Hansen, B ;
Wenzel, A ;
Hintze, H .
CARIES RESEARCH, 2004, 38 (01) :34-38
[16]   In vitro assessment of cone beam local computed tomography for proximal caries detection [J].
Kalathingal, Sajitha M. ;
Mol, Andre ;
Tyndall, Donald A. ;
Caplan, Daniel J. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 104 (05) :699-704
[17]   An in vitro comparison of diagnostic abilities of conventional radiography, storage phosphor, and cone beam computed tomography to determine occlusal and approximal caries [J].
Kayipmaz, Saadettin ;
Sezgin, Omer Said ;
Saricaoglu, Senem Tugra ;
Can, Gamze .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) :478-482
[18]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[19]   Image processing and enhancement provided by commercial dental software programs [J].
Lehmann, TM ;
Troeltsch, E ;
Spitzer, K .
DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (04) :264-272
[20]   EFFECTS OF FILTRATION, COLLIMATION, AND TARGET-RECEPTOR DISTANCE ON ARTIFICIAL APPROXIMAL ENAMEL LESION DETECTION WITH THE USE OF RADIOVISIOGRAPHY [J].
PARKS, ET ;
MILES, DA ;
VANDIS, ML ;
WILLIAMSON, GF ;
RAZMUS, TF ;
BRICKER, SL .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1994, 77 (04) :419-426