Performance of a photostimulable storage phosphor digital system with or without the sharpen filter and cone beam CT for detecting approximal enamel subsurface demineralization

被引:12
作者
Belem, M. D. F. [1 ]
Tabchoury, C. P. M. [1 ]
Ferreira-Santos, R. I. [2 ]
Groppo, F. C. [1 ]
Haiter-Neto, F. [1 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Piracicaba, SP, Brazil
[2] Univ Sao Paulo, UNICID, Dept Pediat Dent & Orthodont, Sao Paulo, Brazil
关键词
tooth demineralization; diagnosis; cone beam CT; digital radiography; COMPUTED-TOMOGRAPHY; PROXIMAL CARIES; DIAGNOSTIC-ACCURACY; SPATIAL-RESOLUTION; VISTASCAN SYSTEM; FILM RADIOGRAPHY; LESIONS; ENHANCEMENT; DEPTH; MODALITIES;
D O I
10.1259/dmfr.20120313
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to assess the performance of photostimulable storage phosphor (PSP) radiographs with or without using the sharpen filter and cone beam CT (CBCT) for detecting enamel subsurface demineralization. Methods: Enamel subsurface demineralization was induced on one of the approximal surfaces of 120 sound human teeth. Standardized images of all teeth were acquired after the demineralization phase using the Digora (R) Optime (Orion Corp./Soredex, Helsinki, Finland) (PSP) and the i-CAT (TM) (Imaging Sciences International, Hatfield, PA) (CBCT) systems. Three calibrated observers interpreted the images using a five-point scale (1, demineralization definitely absent; 2, demineralization probably absent; 3, unsure; 4, demineralization probably present; and 5, demineralization definitely present). Diagnoses were validated by cross-sectional microhardness profiling in the test areas of the approximal surfaces. Interobserver agreement was analysed using kappa statistics. Accuracy was estimated by the areas under the receiver operating characteristic curves (4,), which were compared using the Kruskal Wallis test (alpha = 5%). Results: Interobserver agreement was higher for CBCT (kappa = 0.7-0.8), followed by sharpen-filtered (kappa = 0.6-0.7) and original (kappa = 0.5-0.6) images. CBCT presented the highest accuracy value (A(z) = 0.897) compared with the original (A(z) = 0.792) and sharpen-filtered (A(z) = 0.712) images. However, no statistical differences were observed between the imaging modalities (p = 0.0794). Conclusions: It can be concluded that PSP radiographs with or without using the sharpen filter and the CBCT images may be useful adjuncts for detecting subtle approximal enamel demineralization.
引用
收藏
页数:9
相关论文
共 35 条
[1]   Accuracy of proximal caries depth measurements:: Comparison between limited cone beam computed tomography, storage phosphor and film radiography [J].
Akdeniz, B. Guniz ;
Grondahl, Hans-Goran ;
Magnusson, Bengt .
CARIES RESEARCH, 2006, 40 (03) :202-207
[2]   Radiographic image enhancement. Part I: spatial domain techniques [J].
Analoui, M .
DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (01) :1-9
[3]  
[Anonymous], 2003, ORTHOD CRANIFOC R S1, DOI DOI 10.1007/S13181-011-0207-X
[4]   Development of a compact computed tomographic apparatus for dental use [J].
Arai, Y ;
Tammisalo, E ;
Iwai, K ;
Hashimoto, K ;
Shinoda, K .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :245-248
[5]   DEMINERALIZATION AND REMINERALIZATION EVALUATION TECHNIQUES [J].
ARENDS, J ;
TENBOSCH, JJ .
JOURNAL OF DENTAL RESEARCH, 1992, 71 :924-928
[6]  
Argenta Rosane Maria Orth, 2003, Pesqui Odontol Bras, V17, P241
[7]   Image distortion and spatial resolution of a commercially available cone-beam computed tomography machine [J].
Ballrick, John W. ;
Palomo, J. Martin ;
Ruch, Edward ;
Amberman, B. Douglas ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (04) :573-582
[8]   In vitro induction of enamel subsurface demineralization for evaluation of diagnostic imaging methods [J].
Ferreira, Rivea Ines ;
Haiter-Neto, Francisco ;
Machado Tabchoury, Cinthia Pereira ;
Boscolo, Frab Norberto .
JOURNAL OF APPLIED ORAL SCIENCE, 2007, 15 (05) :392-398
[9]  
Ferreira Rívea Inês, 2006, Braz. oral res., V20, P114, DOI 10.1590/S1806-83242006000200005
[10]   Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions [J].
Haiter-Neto, F. ;
Wenzel, A. ;
Gotfredsen, E. .
DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (01) :18-22