Reduced Radiation Exposure of the Female Breast During Low-Dose Chest CT Using Organ-Based Tube Current Modulation and a Bismuth Shield: Comparison of Image Quality and Radiation Dose

被引:39
作者
Kim, Yoon Kyung [1 ]
Sung, Yon Mi [1 ]
Choi, Jin Ho [2 ]
Kim, Eun Young [1 ]
Kim, Hyung Sik [1 ]
机构
[1] Gachon Univ Med & Sci, Gil Hosp, Dept Radiol, Inchon 405760, South Korea
[2] Gachon Univ Med & Sci, Gil Hosp, Dept Radiat Oncol, Inchon 405760, South Korea
关键词
bismuth shield; breast; chest; CT; radiation dosimetry; MULTIDETECTOR COMPUTED-TOMOGRAPHY; LUNG-CANCER; REDUCTION; PHANTOM; MORTALITY;
D O I
10.2214/AJR.12.9237
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to evaluate the effect of organ-based tube current modulation and bismuth shielding on image quality and breast radiation dose in women undergoing low-dose chest CT. SUBJECTS AND METHODS. From March 2011 through July 2011, 80 women prospectively underwent low-dose chest CT to screen for lung cancer. The patients were randomly assigned to a control group (n = 20), organ-based tube current modulation group (n = 20), breast shield group (n = 20), or breast shield plus organ-based tube current modulation group (n = 20). Axial slice images of the aortic arch, carina, and inferior pulmonary vein were used to analyze image quality. Three radiologists scored the image quality in terms of artifact and noise and then characterized the overall image quality as optimal (does not affect the diagnostic accuracy) or suboptimal (affects the diagnostic accuracy). Noise levels were measured in the anterior and posterior lung in each image. A phantom dose study was conducted to measure radiation dose. RESULTS. Images with artifacts or noise were more frequently obtained in the breast shield groups; however, the overall image quality was not significantly different among the four groups. Measured noise levels in the anterior lung were significantly higher in the breast shield groups than the control group; however, no statistical significance was found among the four groups with regard to noise level in the posterior lung. In the phantom dose study, a 16-37.5% dose reduction in the breast was achieved using the breast shield, organ-based tube current modulation protocol, or both. CONCLUSION. The radiation dose in the female breast may be reduced using a breast shield or organ-based tube current modulation during low-dose chest CT with acceptable image quality. The use of organ-based tube current modulation reduced the radiation dose in the breast without inducing image quality deterioration.
引用
收藏
页码:537 / 544
页数:8
相关论文
共 18 条
[1]   Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening [J].
Aberle, Denise R. ;
Adams, Amanda M. ;
Berg, Christine D. ;
Black, William C. ;
Clapp, Jonathan D. ;
Fagerstrom, Richard M. ;
Gareen, Ilana F. ;
Gatsonis, Constantine ;
Marcus, Pamela M. ;
Sicks, JoRean D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (05) :395-409
[2]  
[Anonymous], 2007, ANN ICRP, V37, P1, DOI 10.1016/j.icrp.2007.11.001
[3]   Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer [J].
Brenner, DJ .
RADIOLOGY, 2004, 231 (02) :440-445
[4]   Dose reduction in multislice CT by means of bismuth shields: results of in vivo measurements and computed evaluation [J].
Catuzzo, P. ;
Aimonetto, S. ;
Fanelli, G. ;
Marchisio, P. ;
Meloni, T. ;
Mistretta, L. ;
Pasquino, M. ;
Richetta, E. ;
Tofani, S. .
RADIOLOGIA MEDICA, 2010, 115 (01) :152-169
[5]   Low-dose lung computed tomography screening before age 55: estimates of the mortality reduction required to outweigh the radiation-induced cancer risk [J].
de Gonzalez, Amy Berrington ;
Kim, Kwang Pyo ;
Berg, Christine D. .
JOURNAL OF MEDICAL SCREENING, 2008, 15 (03) :153-158
[6]   Dose Reduction to Anterior Surfaces With Organ-Based Tube-Current Modulation: Evaluation of Performance in a Phantom Study [J].
Duan, Xinhui ;
Wang, Jia ;
Christner, Jodie A. ;
Leng, Shuai ;
Grant, Katharine L. ;
McCollough, Cynthia H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) :689-695
[7]   Breast Surface Radiation Dose During Coronary CT Angiography: Reduction by Breast Displacement and Lead Shielding [J].
Foley, Shane J. ;
McEntee, Mark F. ;
Achenbach, Stephan ;
Brennan, Patrick C. ;
Rainford, Louise S. ;
Dodd, Jonathan D. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) :367-373
[8]   In-plane bismuth breast shields for pediatric CT: Effects on radiation dose and image quality using experimental and clinical data [J].
Fricke, BL ;
Donnelly, LF ;
Frush, DP ;
Yoshizumi, T ;
Varchena, V ;
Poe, SA ;
Lucaya, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (02) :407-411
[9]   Detection of Nodules Showing Ground-Glass Opacity in the Lungs at Low-Dose Multidetector Computed Tomography: Phantom and Clinical Study [J].
Funama, Yoshinori ;
Awai, Kazuo ;
Liu, Duo ;
Oda, Seitaro ;
Yanaga, Yumi ;
Nakaura, Takeshi ;
Kawanaka, Koichi ;
Shimamura, Masamichi ;
Yamashita, Yasuyuki .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (01) :49-53
[10]   Automated Computed Tomography Dose-Saving Algorithm to Protect Radiosensitive Tissues Estimation of Radiation Exposure and Image Quality Considerations [J].
Ketelsen, Dominik ;
Buchgeister, Markus ;
Fenchel, Michael ;
Schmidt, Bernhard ;
Flohr, Thomas G. ;
Syha, Roland ;
Thomas, Christoph ;
Tsiflikas, Ilias ;
Claussen, Claus D. ;
Heuschmid, Martin .
INVESTIGATIVE RADIOLOGY, 2012, 47 (02) :148-152