Survey of computed tomography techniques and absorbed dose in Italian hospitals: a comparison between two methods to estimate the dose-length product and the effective dose and to verify fulfilment of the diagnostic reference levels

被引:24
作者
Origgi, D
Vigorito, S
Villa, G
Bellomi, M
Tosi, G
机构
[1] European Inst Oncol, Dept Med Phys, I-20141 Milan, Italy
[2] European Inst Oncol, Div Radiol, I-20141 Milan, Italy
[3] Univ Milan, Sch Med, Milan, Italy
关键词
computed tomography; patient exposure; effective dose; dose-length product; diagnostic reference levels;
D O I
10.1007/s00330-005-2682-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was the production of the first Italian survey of radiation dose in computed tomography (CT) prior to the widespread adoption of multislice CT, in order to have a reference point to facilitate later investigation of dose exposure changes brought by this new CT modality. The collected dose data were compared with diagnostic reference levels (DRLs). The agreement between experimental dose evaluation and Monte Carlo (MC) simulations was investigated. The survey was carried out in 29 Italian hospitals, covered 48 CT scanners and 232 examinations. The dose-length product (DLP) and effective dose (E) values were estimated based on MC simulations for seven clinical protocols using the CT-Dose program. Statistical analysis showed a significant difference (p < 0.01) in the DLP between the two methods, with MC values being greater than the experimental ones. For E, the MC values were greater in routine head (8.2%), cervical spine (2.7%) and lumbar spine (2.9%) studies. The weighted CT dose index, the DLP and E were always below the DRLs set by the European Community. This dose survey gives a good but incomplete picture of the Italian CT dose situation and may be useful as a reference baseline for defining clinical multislice protocols in the near future.
引用
收藏
页码:227 / 237
页数:11
相关论文
共 24 条
  • [1] [Anonymous], 1994, 61267 IEC
  • [2] Baadegaard N, 1999, CT DOSE CALCULATION
  • [3] Assessment of a theoretical formalism for dose estimation in CT: an anthropomorphic phantom study
    Brix, G
    Lechel, U
    Veit, R
    Truckenbrodt, R
    Stamm, G
    Coppenrath, EM
    Griebel, J
    Nagel, HD
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (07) : 1275 - 1284
  • [4] Quality criteria implementation for brain and lumbar spine CT examinations
    Calzado, A
    Rodríguez, R
    Muñoz, A
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (868) : 384 - 395
  • [5] Application of draft European Commission reference levels to a regional CT dose survey
    Clarke, J
    Cranley, K
    Robinson, J
    Smith, PHS
    Workman, A
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (865) : 43 - 50
  • [6] A practical approach to the first iteration in the optimization of radiation dose and image quality in CT: estimates of the collective dose savings achieved
    Crawley, MT
    Booth, A
    Wainwright, A
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (883) : 607 - 614
  • [7] Abdominal CT and the Euratom Directive
    Dixon, AK
    Goldstone, KE
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (06) : 1567 - 1570
  • [8] *EUR COMM, 1998, 16262 EUR COMM
  • [9] Radiation doses from CT in the Sultanate of Oman
    Goddard, CC
    Al-Farsi, A
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (863) : 1073 - 1077
  • [10] Relationships between physical dose quantities and patient dose in CT
    Hidajat, N
    Mäurer, J
    Schröder, RJ
    Nunnemann, A
    Wolf, M
    Pauli, K
    Felix, R
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (858) : 556 - 561