Validation of a portable bioelectrical impedance analyzer for the assessment of body composition

被引:90
作者
Karelis, Antony D. [1 ,2 ]
Chamberland, Gabriel [1 ]
Aubertin-Leheudre, Mylene [1 ,2 ]
Duval, Christian [1 ,2 ]
机构
[1] Univ Quebec, Dept Kinanthropol, Montreal, PQ H3C 3P8, Canada
[2] Montreal Geriatr Res Inst, Montreal, PQ H3W 1W5, Canada
来源
APPLIED PHYSIOLOGY NUTRITION AND METABOLISM-PHYSIOLOGIE APPLIQUEE NUTRITION ET METABOLISME | 2013年 / 38卷 / 01期
关键词
Inbody; 230; dual X-ray absorptiometry; % body fat; fat free mass; X-RAY ABSORPTIOMETRY; BIOIMPEDANCE ANALYSIS; CHILDREN; OBESITY; ADULTS; FAT; POPULATION; OVERWEIGHT; VALIDITY; FATNESS;
D O I
10.1139/apnm-2012-0129
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
One of the major challenges in field research has been the difficulty to adequately measure body composition, such as % body fat and fat-free mass (FFM). Therefore, the purpose of the present study was to investigate the convergent validity of the portable bioelectrical impedance body composition analyzer, the Inbody 230, with dual X-ray absorptiometry (DXA) (General Electric Lunar Prodigy). The study population consisted of 145 men and women (age, 44.6 +/- 20 years; BMI, 24.5 +/- 3.8 kg.m(-2)). We measured body composition (fat mass, % body fat, total FFM, trunk FFM, and appendicular FFM) using DXA and the Inbody 230. Results show strong significant correlations between both methods for fat mass, % body fat, total FFM, and trunk FFM (r = 0.94-0.99). Furthermore, we showed a modest significant correlation between both methods for appendicular FFM (r = 0.63). Finally, as shown by Bland-Altman analysis, no significant biases were observed between Inbody 230 and DXA for fat mass, % body fat, and total FFM. However, trunk and appendicular FFM were shown to have significant biases between the Inbody 230 and DXA. In conclusion, the present study indicated that the portable Inbody 230 may be an acceptable device to measure fat mass, % body fat, and total FFM (except for women) in healthy adults. In addition, there appears to be a systematic bias for the estimation of trunk and appendicular FFM with the Inbody 230 in men and women.
引用
收藏
页码:27 / 32
页数:6
相关论文
共 19 条
[11]   Cross-calibration of multi-frequency bioelectrical impedance analysis with eight-point tactile electrodes and dual-energy X-ray absorptiometry for assessment of body composition in healthy children aged 6-18 years [J].
Lim, Jung S. ;
Hwang, Jin S. ;
Lee, Jun A. ;
Kim, Dong H. ;
Park, Kyung D. ;
Jeong, Jin S. ;
Cheon, Gi J. .
PEDIATRICS INTERNATIONAL, 2009, 51 (02) :263-268
[12]   Accuracy of direct segmental multi-frequency bioimpedance analysis in the assessment of total body and segmental body composition in middle-aged adult population [J].
Ling, Carolina H. Y. ;
de Craen, Anton J. M. ;
Slagboom, Pieternella E. ;
Gunn, Dave A. ;
Stokkel, Marcel P. M. ;
Westendorp, Rudi G. J. ;
Maier, Andrea B. .
CLINICAL NUTRITION, 2011, 30 (05) :610-615
[13]   Bioelectrical impedance underestimates total and truncal fatness in abdominally obese women [J].
Neovius, Martin ;
Hemmingsson, Erik ;
Freyschuss, Bo ;
Udden, Joanna .
OBESITY, 2006, 14 (10) :1731-1738
[14]   Comparison of three bioelectrical impedance methods with DXA in overweight and obese men [J].
Pateyjohns, Ian R. ;
Brinkworth, Grant D. ;
Buckley, Jonathan D. ;
Noakes, Manny ;
Clifton, Peter M. .
OBESITY, 2006, 14 (11) :2064-2070
[15]   New bioimpedance analysis system: improved phenotyping with whole-body analysis [J].
Pietrobelli, A ;
Rubiano, F ;
St-Onge, MP ;
Heymsfield, SB .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2004, 58 (11) :1479-1484
[16]   Prediction of Fatness by Standing 8-Electrode Bioimpedance: A Multiethnic Adolescent Population [J].
Sluyter, John D. ;
Schaaf, David ;
Scragg, Robert K. R. ;
Plank, Lindsay D. .
OBESITY, 2010, 18 (01) :183-189
[17]  
Sun G, 2005, AM J CLIN NUTR, V81, P74
[18]   Assessing body composition with DXA and bioimpedance:: Effects of obesity, physical activity, and age [J].
Volgyi, Eszter ;
Tylavsky, Frances A. ;
Lyytikainen, Arja ;
Suominen, Harri ;
Alen, Markku ;
Cheng, Sulin .
OBESITY, 2008, 16 (03) :700-705
[19]   Validation of a three-frequency bioimpedance spectroscopic method for body composition analysis [J].
Ward, Leigh C. ;
Dyer, Julia M. ;
Byrne, Nuala M. ;
Sharpe, Kendall K. ;
Hills, Andrew P. .
NUTRITION, 2007, 23 (09) :657-664