COMPARISON OF TWO IN VIVO MICROSCOPY TECHNIQUES TO VISUALIZE ALVEOLAR MECHANICS

被引:30
作者
Bickenbach, Johannes [1 ]
Dembinski, Rolf [1 ]
Czaplik, Michael [2 ]
Meissner, Sven [3 ]
Tabuchi, Arata [7 ]
Mertens, Michael [7 ]
Knels, Lila [8 ]
Schroeder, Wolfgang [4 ]
Pelosi, Paolo [5 ]
Koch, Edmund [3 ]
Kuebler, Wolfgang M. [7 ]
Rossaint, Rolf [1 ,2 ]
Kuhlen, Ralf [6 ]
机构
[1] Univ Hosp RWTH Aachen, Dept Surg Intens Care, D-52074 Aachen, Germany
[2] Univ Hosp RWTH Aachen, Dept Anaesthesiol, D-52074 Aachen, Germany
[3] Tech Univ Dresden, Fac Med, Dresden, Germany
[4] Rhein Westfal TH Aachen, Inst Aerodynam, D-52062 Aachen, Germany
[5] Univ Insubria, Dept Environm Hlth & Safety, Varese, Italy
[6] Helios Hosp Berlin Buch, Dept Intens Care Med, Berlin, Germany
[7] Charite, Inst Physiol, D-13353 Berlin, Germany
[8] Univ Hosp Dresden, Dept Anesthesiol, Dresden, Germany
关键词
in vivo microscopy; alveolar mechanics; mechanical ventilation;
D O I
10.1007/s10877-009-9200-1
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective. In conventional in vivo microscopy, a three dimensional illustration of tissue is lacking. Concerning the microscopic analysis of the pulmonary alveolar network, surgical preparation of the thorax and fixation of the lung is required to place the microscope's objective. These effects may have influence on the mechanical behaviour of alveoli. Relatively new methods exist for in vivo microscopy being less invasive and enabling an observation without fixation of the lung. The aim of this study was to compare a fibered confocal laser scanning microscopy (FCLSM) with optical coherence tomography (OCT) in a mouse and a rabbit model. Moreover, FCLSM was also used endoscopically in the rabbit model. Methods. Smallest possible thoracic windows were excised at the lower margin of the upper right lung lobe and an interpleural catheter inserted before re-coverage with a transparent membrane foil. The OCT-scanner was positioned by a motor driven translation stage. The imaging was gated to endinspiratory plateau. For CLSM, Fluorescein 0.1% was given into the central venous streak line. The confocal probe with a diameter of 650 mu m was carefully positioned at the very same lung region. Images were directly recorded real-time and the observed region qualitatively compared with FD-OCT images. Additionally, in the rabbit model, CLSM was used endoscopically under bronchoscopic sight control. In a post-processing analysis, images taken were analyzed and compared by using an "air index" (AI). Results. In the mouse model, the very same region could be re-identified with both techniques. Concerning alveolar shape and size, qualitatively comparable images could be gained. The AI was 40.5% for the OCT and 40.1% for the CLSM images. In the rabbit, even an endoscopic view on alveoli was possible. Likewise AI was 43.2% for CLSM through the thoracic window and 43.6% from endoscopically. For the OCT an AI of 44.6% was analysed in the rabbit model. Conclusions. Both FD-OCT and CLSM provide high-resolution images of alveolar structure giving depth information that is beneficial to conventional microscopy. CLSM also facilitates endoscopic view on alveoli being well comparable to images gained through a thoracic window.
引用
收藏
页码:323 / 332
页数:10
相关论文
共 15 条
[1]  
Carney David, 2005, Crit Care Med, V33, pS122, DOI 10.1097/01.CCM.0000155928.95341.BC
[2]   Dynamic alveolar mechanics in four models of lung injury [J].
DiRocco, JD ;
Pavone, LA ;
Carney, DE ;
Lutz, CJ ;
Gatto, LA ;
Landas, SK ;
Nieman, GF .
INTENSIVE CARE MEDICINE, 2006, 32 (01) :140-148
[3]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[4]  
Häusler G, 1998, J BIOMED OPT, V3, P21, DOI 10.1117/1.429899
[5]  
Halter JM, 2007, CRIT CARE, V11, DOI 10.1186/cc5695
[6]   Positive end-expiratory pressure after a recruitment maneuver prevents both alveolar collapse and recruitment/derecruitment [J].
Halter, JM ;
Steinberg, JM ;
Schiller, HJ ;
DaSilva, M ;
Gatto, LA ;
Lanclas, S ;
Nieman, GF .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2003, 167 (12) :1620-1626
[7]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[8]  
Le Goualher G, 2004, LECT NOTES COMPUT SC, V3217, P761
[9]   Injurious mechanical ventilation in the normal lung causes a progressive pathologic change in dynamic alveolar mechanics [J].
Pavone, Lucio A. ;
Albert, Scott ;
Carney, David ;
Gatto, Louis A. ;
Halter, Jeffrey M. ;
Nieman, Gary F. .
CRITICAL CARE, 2007, 11 (03)
[10]   Imaging of the three-dimensional alveolar structure and the alveolar mechanics of a ventilated and perfused isolated rabbit lung with Fourier domain optical coherence tomography [J].
Popp, A ;
Wendel, M ;
Knels, L ;
Koch, T ;
Koch, E .
JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (01)