A Quantitative Pixel-Wise Measurement of Myocardial Blood Flow by Contrast-Enhanced First-Pass CMR Perfusion Imaging Microsphere Validation in Dogs and Feasibility Study in Humans

被引:117
作者
Hsu, Li-Yueh [1 ]
Groves, Daniel W. [1 ]
Aletras, Anthony H. [1 ]
Kellman, Peter [1 ]
Arai, Andrew E. [1 ]
机构
[1] NHLBI, Adv Cardiovasc Imaging Lab, NIH, US Dept HHS, Bethesda, MD 20892 USA
关键词
cardiac magnetic resonance; gadolinium; myocardial ischemia; myocardial perfusion; CORONARY-ARTERY-DISEASE; MAGNETIC-RESONANCE PERFUSION; MODEL-INDEPENDENT DECONVOLUTION; POSITRON-EMISSION-TOMOGRAPHY; MR PERFUSION; SPATIAL HETEROGENEITY; NONINVASIVE DETECTION; COMPUTED-TOMOGRAPHY; QUANTIFICATION; RESERVE;
D O I
10.1016/j.jcmg.2011.07.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of this study was to evaluate fully quantitative myocardial blood flow (MBF) at a pixel level based on contrast-enhanced first-pass cardiac magnetic resonance (CMR) imaging in dogs and in patients. BACKGROUND Microspheres can quantify MBF in subgram regions of interest, but CMR perfusion imaging may be able to quantify MBF and differentiate blood flow at a much higher resolution. METHODS First-pass CMR perfusion imaging was performed in a dog model with local hyperemia induced by intracoronary adenosine. Fluorescent microspheres were the reference standard for MBF validation. CMR perfusion imaging was also performed on patients with significant coronary artery disease (CAD) by invasive coronary angiography. Myocardial time-signal intensity curves of the images were quantified on a pixel-by-pixel basis using a model-constrained deconvolution analysis. RESULTS Qualitatively, color CMR perfusion pixel maps were comparable to microsphere MBF bull's-eye plots in all animals. Pixel-wise CMR MBF estimates correlated well against subgram (0.49 +/- 0.14 g) microsphere measurements (r = 0.87 to 0.90) but showed minor underestimation of MBF. To reduce bias due to misregistration and minimize issues related to repeated measures, 1 hyperemic and 1 remote sector per animal were compared with the microsphere MBF, which improved the correlation (r = 0.97 to 0.98), and the bias was close to zero. Sector-wise and pixel-wise CMR MBF estimates also correlated well (r = 0.97). In patients, color CMR stress perfusion pixel maps showed regional blood flow decreases and transmural perfusion gradients in territories served by stenotic coronary arteries. MBF estimates in endocardial versus epicardial subsectors, and ischemic versus remote sectors, were all significantly different (p < 0.001 and p < 0.01, respectively). CONCLUSIONS Myocardial blood flow can be quantified at the pixel level (similar to 32 mu l of myocardium) on CMR perfusion images, and results compared well with microsphere measurements. High-resolution pixel-wise CMR perfusion maps can quantify transmural perfusion gradients in patients with CAD. (J Am Coll Cardiol Img 2012;5:154-66) (C) 2012 by the American College of Cardiology Foundation
引用
收藏
页码:154 / 166
页数:13
相关论文
共 49 条
[1]   Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance [J].
Al-Saadi, N ;
Nagel, E ;
Gross, M ;
Bornstedt, A ;
Schnackenburg, B ;
Klein, C ;
Klimek, W ;
Oswald, H ;
Fleck, E .
CIRCULATION, 2000, 101 (12) :1379-1383
[2]   PROFOUND SPATIAL HETEROGENEITY OF CORONARY RESERVE - DISCORDANCE BETWEEN PATTERNS OF RESTING AND MAXIMAL MYOCARDIAL BLOOD-FLOW [J].
AUSTIN, RE ;
ALDEA, GS ;
COGGINS, DL ;
FLYNN, AE ;
HOFFMAN, JIE .
CIRCULATION RESEARCH, 1990, 67 (02) :319-331
[3]   TISSUE MEAN TRANSIT-TIME FROM DYNAMIC COMPUTED-TOMOGRAPHY BY A SIMPLE DECONVOLUTION TECHNIQUE [J].
AXEL, L .
INVESTIGATIVE RADIOLOGY, 1983, 18 (01) :94-99
[4]   FRACTAL NATURE OF REGIONAL MYOCARDIAL BLOOD-FLOW HETEROGENEITY [J].
BASSINGTHWAIGHTE, JB ;
KING, RB ;
ROGER, SA .
CIRCULATION RESEARCH, 1989, 65 (03) :578-590
[5]   MOLECULAR AND PARTICULATE DEPOSITIONS FOR REGIONAL MYOCARDIAL FLOWS IN SHEEP [J].
BASSINGTHWAIGHTE, JB ;
MALONE, MA ;
MOFFETT, TC ;
KING, RB ;
CHAN, IS ;
LINK, JM ;
KROHN, KA .
CIRCULATION RESEARCH, 1990, 66 (05) :1328-1344
[6]   Automated registration of dynamic MR images for the quantification of myocardial perfusion [J].
Bidaut, LM ;
Vallée, JP .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :648-655
[7]   Combined coronary and perfusion cardiovascular magnetic resonance for the assessment of coronary artery stenosis [J].
Bunce, NH ;
Reyes, E ;
Keegan, J ;
Bunce, C ;
Davies, SW ;
Lorenz, CH ;
Pennell, DJ .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2004, 6 (02) :527-539
[8]   Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging [J].
Christian, TF ;
Rettmann, DW ;
Aletras, AH ;
Liao, SL ;
Taylor, JL ;
Balaban, RS ;
Arai, AE .
RADIOLOGY, 2004, 232 (03) :677-684
[9]   Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: Comparison to single-bolus injection method [J].
Christian, Timothy F. ;
Aletras, Anthony H. ;
Arai, Andrew E. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) :1271-1277
[10]   Realignment of myocardial first-pass MR perfusion images using an automatic detection of the heart-lung interface [J].
Comte, A ;
Lalande, A ;
Aho, S ;
Walker, PM ;
Brunotte, F .
MAGNETIC RESONANCE IMAGING, 2004, 22 (07) :1001-1009