共 50 条
CT-based Diagnosis of Diffuse Coronary Artery Disease on the Basis of Scaling Power Laws
被引:17
作者:
Huo, Yunlong
[1
]
Wischgoll, Thomas
[5
]
Choy, Jenny Susana
[1
]
Sola, Srikanth
[6
]
Navia, Jose L.
[6
]
Teague, Shawn D.
[2
]
Bhatt, Deepak L.
[7
]
Kassab, Ghassan S.
[1
,3
,4
]
机构:
[1] Indiana Univ Purdue Univ Indianapolis, Dept Biomed Engn, Indianapolis, IN 46202 USA
[2] Indiana Univ Purdue Univ Indianapolis, Dept Radiol, Indianapolis, IN 46202 USA
[3] Indiana Univ Purdue Univ Indianapolis, Dept Surg, Indianapolis, IN 46202 USA
[4] Indiana Univ Purdue Univ Indianapolis, Dept Cellular & Integrat Physiol, Indianapolis, IN 46202 USA
[5] Wright State Univ, Dept Elect & Comp Engn, Dayton, OH 45435 USA
[6] Cleveland Clin, Dept Cardiovasc Surg, Cleveland, OH 44106 USA
[7] Harvard Univ, Brigham & Womens Hosp, Sch Med, VA Boston Healthcare Syst, Boston, MA 02115 USA
来源:
基金:
美国国家卫生研究院;
关键词:
INTRAVASCULAR ULTRASOUND;
MYOCARDIAL-INFARCTION;
VASCULAR TREE;
FLOW;
PROGRESSION;
SIZE;
ATHEROSCLEROSIS;
ARTERIOGRAMS;
ANGIOGRAPHY;
MORPHOMETRY;
D O I:
10.1148/radiol.13122181
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: To provide proof of concept for a diagnostic method to assess diffuse coronary artery disease (CAD) on the basis of coronary computed tomography (CT) angiography. Materials and Methods: The study was approved by the Cleveland Clinic Institutional Review Board, and all subjects gave informed consent. Morphometric data from the epicardial coronary artery tree, determined with CT angiography in 120 subjects (89 patients with metabolic syndrome and 31 ageand sex-matched control subjects) were analyzed on the basis of the scaling power law. Results obtained in patients with metabolic syndrome and control subjects were compared statistically. Results: The mean lumen cross-sectional area (ie, lumen cross-sectional area averaged over each vessel of an epicardial coronary artery tree) and sum of intravascular volume in patients with metabolic syndrome (0.039 cm(2) +/- 0.015 [standard deviation] and 2.71 cm(3) +/- 1.75, respectively) were significantly less than those in control subjects (0.054 cm(2) +/- 0.015 and 3.29 cm(3) +/- 1.77, respectively; P < .05). The length-volume power law showed coefficients of 27.0 cm(-4/3) +/- 9.0 (R-2 = 0.91 6 0.08) for patients with metabolic syndrome and 19.9 cm(-4/3) +/- 4.3 (R-2 = 0.92 6 0.07) for control subjects (P < .05). The probability frequency shows that more than 65% of patients with metabolic syndrome had a coefficient of 23 or more for the length-volume scaling power law, whereas approximately 90% of the control subjects had a coefficient of less than 23. Conclusion: The retrospective scaling analysis provides a quantitative rationale for diagnosis of diffuse CAD. (C) RSNA, 2013
引用
收藏
页码:694 / 701
页数:8
相关论文
共 50 条