Determination of single-kidney glomerular filtration rate (GFR) with CT urography versus renal dynamic imaging Gates method

被引:20
作者
You, Shan [1 ]
Ma, XianWu [2 ]
Zhang, ChangZhu [2 ]
Li, Qiang [2 ]
Shi, WenWei [3 ]
Zhang, Jing [3 ]
Yuan, XiaoDong [3 ]
机构
[1] Hebei North Univ, Dept Grad, 11 Diamond South Rd, Zhangjiakou City 075000, Hebei, Peoples R China
[2] Qiqihar Chinese Med Hosp, Dept Radiol, 23 Ping An Nan Jie, Qigihar City 161005, Heilongjiang, Peoples R China
[3] Chinese Peoples Liberat Army, Hosp 309, Dept Radiol, 17 Heishanhu Rd, Beijing 100091, Peoples R China
基金
中国国家自然科学基金;
关键词
Computed tomography (CT); CT urography; Glomerular filtration rate (GFR); Split renal function; One-stop-shop technique; BRAIN TRANSFER CONSTANTS; HELICAL CT; COMPUTED-TOMOGRAPHY; GRAPHICAL EVALUATION; CONTRAST-MEDIA; CLEARANCE; DISEASE;
D O I
10.1007/s00330-017-5061-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To present a single-kidney CT-GFR measurement and compare it with the renal dynamic imaging Gates-GFR. Thirty-six patients with hydronephrosis referred for CT urography and 99mTc-DTPA renal dynamic imaging were prospectively included. Informed consent was obtained from all patients. The CT urography protocol included non-contrast, nephrographic, and excretory phase imaging. The total CT-GFR was calculated by dividing the CT number increments of the total urinary system between the nephrographic and excretory phase by the products of iodine concentration in the aorta and the elapsed time, then multiplied by (1- Haematocrit). The total CT-GFR was then split into single-kidney CT-GFR by a left and right kidney proportionality factor. The results were compared with single-kidney Gates-GFR by using paired t-test, correlation analysis, and Bland-Altman plots. Paired difference between single-kidney CT-GFR (45.02 +/- 13.91) and single-kidney Gates-GFR (51.21 +/- 14.76) was 6.19 +/- 5.63 ml/min, p < 0.001, demonstrating 12.1% systematic underestimation with +/- 11.03 ml/min (+/- 21.5%) measurement deviation. A good correlation was revealed between both measurements (r=0.87, p < 0.001). The proposed single-kidney CT-GFR correlates and agrees well with the reference standard despite a systematic underestimation, therefore it could be a one-stop-shop for evaluating urinary tract morphology and split renal function. aEuro cent A new CT method can assess split renal function aEuro cent Only using images from CT urography and the value of haematocrit aEuro cent A one-stop-shop CT technique without additional radiation dose.
引用
收藏
页码:1077 / 1084
页数:8
相关论文
共 30 条
  • [1] Glomerular Filtration Rate in Evaluation of the Effect of Iodinated Contrast Media on Renal Function
    Becker, Joshua
    Babb, James
    Serrano, Manuel
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (04) : 822 - 826
  • [2] The quantification of renal function with enhanced computed tomography
    Blomley, MJK
    Dawson, P
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (827) : 989 - 995
  • [3] Comparison of mathematic models for assessment of glomerular filtration rate with electron-beam CT in pigs
    Daghini, Elena
    Juillard, Laurent
    Haas, John A.
    Krier, James D.
    Romero, Juan C.
    Lerman, Lilach O.
    [J]. RADIOLOGY, 2007, 242 (02) : 417 - 424
  • [4] DYNAMIC CONTRAST BOLUS COMPUTED-TOMOGRAPHY FOR THE ASSESSMENT OF RENAL-FUNCTION
    DAWSON, P
    PETERS, M
    [J]. INVESTIGATIVE RADIOLOGY, 1993, 28 (11) : 1039 - 1042
  • [5] GLOMERULAR AND RENAL HEMODYNAMICS DURING CONVERTING ENZYME-INHIBITION (SQ20,881) IN THE DOG
    GABRIEL, L
    LAGRANGE, RA
    BELL, PD
    THOMAS, CE
    PLOTH, DW
    [J]. HYPERTENSION, 1979, 1 (04) : 371 - 377
  • [6] A clinical MRI investigation of the relationship between kidney volume measurements and renal function in patients with renovascular disease
    Gandy, S. J.
    Armoogum, K.
    Nicholas, R. S.
    McLeay, T. B.
    Houston, J. G.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (949) : 12 - 20
  • [8] THE DIAGNOSTIC SUPERIORITY OF COMPUTERIZED-TOMOGRAPHY
    GOLDSTEIN, AS
    SCLAFANI, SJA
    KUPFERSTEIN, NH
    BASS, I
    LEWIS, T
    PANETTA, T
    PHILLIPS, T
    SHAFTAN, GW
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1985, 25 (10) : 938 - 946
  • [9] Glomerular filtration rate measured by using triphasic helical CT with a two-point Patlak plot technique
    Hackstein, N
    Wiegand, C
    Rau, WS
    Langheinrich, AC
    [J]. RADIOLOGY, 2004, 230 (01) : 221 - 226
  • [10] Measuring single-kidney glomerular filtration rate on single-detector helical CT using a two-point Patlak plot technique in patients with increased interstitial space
    Hackstein, N
    Bauer, J
    Hauck, EW
    Ludwig, M
    Krämer, HJ
    Rau, WS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (01) : 147 - 156