Development of Digital Multi-channel and Time-division Pulse Height Analyzer Based on PXIE Bus for Hard X-ray Diagnostic in East

被引:6
作者
Cao, Hong-Rui [1 ,2 ]
Wang, Hai-Xiang [1 ]
Zheng, Ying-Ying [2 ,3 ,4 ]
Liu, Shi-Xing [1 ]
Zhao, Jin-Long [2 ]
Zhang, Ji-Zong [2 ]
Lin, Shi-Yao [2 ]
Hu, Li-Qun [2 ]
机构
[1] Hefei Univ Technol, Hefei 230009, Peoples R China
[2] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
[3] Univ Sci & Technol China, Hefei 230026, Peoples R China
[4] PLA Army Acad Artillery & Air Def, Hefei 230031, Peoples R China
关键词
Electric discharges - Spectroscopy - Computer programming languages - Digital storage - Spectrum analysis - Magnetoplasma;
D O I
10.1134/S002044122004003X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Pulse height analyzer (PHA) is an important component of hard X-ray diagnostic to measure energy spectrum in experimental advanced superconducting tokamak (EAST). In order to satisfy physics research of high parameters plasma, the energy resolution, time resolution and number of channels of PHA are required to be improved. A Multi-channel and time-division PHA (MTPHA) based on PXIe bus is designed using 16 bit ADC and FPGA as core processing unit, and has a maximum number of channel addresses of 4096 and minimum time resolution of 2 ms. The function of energy spectrum analysis is realized in the FPGA. Moreover, the PXIe communication drive is realized by combination of hardware code in FPGA and LabVIEW software in host computer. The MTPHA performance has been tested in the lab with pulse generator,Eu-152 isotope radiation source and tested in plasma discharge of EAST. It is found in the lab that the full width at half maxima (FWHM) of MTPHA is no more than 2 channels, and the linear correlation coefficientRof pulse height and channel address is 1. In EAST, the MTPHA can work well and produce experimental data consistent with other diagnostics.
引用
收藏
页码:453 / 460
页数:8
相关论文
共 7 条
[1]   High-speed FPGA-based pulse-height analyzer for high resolution X-ray spectroscopy [J].
Buzzetti, S ;
Capou, M ;
Guazzoni, C ;
Longoni, A ;
Mariani, R ;
Moser, S .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) :854-860
[2]   Development of a fast electron bremsstrahlung diagnostic system based on LYSO and silicon photomultipliers during lower hybrid current drive for tokamak [J].
Fan, Weiwei ;
Zheng, Bowen ;
Cao, Jing ;
Tang, Shibiao ;
Yang, Qingwei ;
Yin, Zejie .
PLASMA SCIENCE & TECHNOLOGY, 2019, 21 (06)
[3]   Development of Multichannel Analyzer Using Sound Card ADC for Nuclear Spectroscopy System [J].
Ibrahim, Maslina Mohd ;
Yussup, Nolida ;
Lombigit, Lojius ;
Rahman, Nur Aira Abdul ;
Jaafar, Zainudin .
ADVANCING NUCLEAR RESEARCH AND ENERGY DEVELOPMENT, 2014, 1584 :50-53
[4]   A time-sharing multi-channel pulse amplitude analyzer [J].
Jiang, Lian-Jun ;
Zhou, Xiang ;
Wu, Tong-Yu ;
Yin, Ze-Jie .
NUCLEAR SCIENCE AND TECHNIQUES, 2017, 28 (04)
[5]   A real-time n/γ digital pulse shape discriminator based on FPGA [J].
Li, Shiping ;
Xu, Xiufeng ;
Cao, Hongrui ;
Yuan, Guoliang ;
Yang, Qingwei ;
Yin, Zejie .
APPLIED RADIATION AND ISOTOPES, 2013, 72 :30-34
[6]   Hard X-ray PHA system on the HT-7 tokamak [J].
Lin Shiyao ;
Shi Yuejiang ;
Wan Baonian ;
Chen Zhongyong ;
Hu Liqun .
PLASMA SCIENCE & TECHNOLOGY, 2006, 8 (03) :261-264
[7]  
Xi Y., 2013, NUCL TECHNOL, V36, P16