Quantification of ephedrines in urine by column-switching high-performance liquid chromatography

被引:12
|
作者
Gmeiner, G [1 ]
Geisendorfer, T [1 ]
Kainzbauer, J [1 ]
Nikolajevic, M [1 ]
Tausch, H [1 ]
机构
[1] Austrian Res Ctr, A-2444 Seibersdorf, Austria
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 768卷 / 02期
关键词
ephedrines;
D O I
10.1016/S0378-4347(01)00545-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for the quantification of five congener ephedrines in urine samples without sample preparation was developed. The analytes were trapped on a C-18 precolumn and separated on a C-18 BDS analytical column. Baseline separation was achieved for all analytes. The method meets the requirements of the International Olympic Committee (IOC) medical commission regarding cut-off limits for positive doping cases with ephedrines. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 50 条
  • [1] DETERMINATION OF OXIRACETAM IN PLASMA AND URINE BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LECAILLON, JB
    SOUPPART, C
    LEDUIGOU, F
    DUBOIS, JP
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 497 : 223 - 230
  • [2] A COLUMN-SWITCHING TECHNIQUE FOR THE SCREENING OF DIURETICS IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SAARINEN, M
    SIREN, H
    RIEKKOLA, ML
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (18): : 4063 - 4078
  • [3] SIMULTANEOUS QUANTIFICATION OF ZIDOVUDINE AND ITS METABOLITES IN SERUM AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING A COLUMN-SWITCHING TECHNIQUE
    LACROIX, C
    HOANG, TP
    WOJCIECHOWSKI, F
    DUWOOS, H
    NOUVEAU, J
    DIQUET, B
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 525 (01): : 240 - 245
  • [4] Analysis of tetracyclines in raw urine by column-switching high-performance liquid chromatography and tandem mass spectrometry
    Weimann, A
    Bojesen, G
    JOURNAL OF CHROMATOGRAPHY B, 1999, 721 (01): : 47 - 54
  • [5] Quantification of 2-hydroxyfluorene in human urine by column-switching high performance liquid chromatography with fluorescence detection
    Toriba, A
    Chetiyanukornkul, T
    Kizu, R
    Hayakawa, K
    ANALYST, 2003, 128 (06) : 605 - 610
  • [6] AUTOMATED-DETERMINATION OF HYPOXANTHINE AND XANTHINE IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING
    SUMI, S
    KIDOUCHI, K
    OHBA, S
    WADA, Y
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 670 (02): : 376 - 378
  • [7] Simultaneous quantification of six ephedrines in a Mahwang preparation and in urine by high-performance liquid chromatography
    Chan, KH
    Pan, RN
    Hsu, MC
    BIOMEDICAL CHROMATOGRAPHY, 2005, 19 (05) : 337 - 342
  • [8] DETERMINATION OF EPHEDRINES IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    IMAZ, C
    CARRERAS, D
    NAVAJAS, R
    RODRIGUEZ, C
    RODRIGUEZ, AF
    MAYNAR, J
    CORTES, R
    JOURNAL OF CHROMATOGRAPHY, 1993, 631 (1-2): : 201 - 205
  • [9] Direct Determination of Benzamides in Serum by Column-Switching High-Performance Liquid Chromatography
    Ryoko Chiba
    Ayako Ogasawara
    Teppei Kubo
    Hiroyuki Yamazaki
    Masuo Umino
    Yoichi Ishizuka
    Analytical Sciences, 2003, 19 : 785 - 789