Reliability of Intra-Retinal Layer Thickness Estimates

被引:75
作者
Oberwahrenbrock, Timm [1 ]
Weinhold, Maria [2 ]
Mikolajczak, Janine [1 ]
Zimmermann, Hanna [1 ]
Paul, Friedemann [1 ,3 ]
Beckers, Ingeborg [2 ]
Brandt, Alexander U. [1 ]
机构
[1] Charite, NeuroCure Clin Res Ctr, D-13353 Berlin, Germany
[2] Beuth Univ Appl Sci, Opt & Laser Technol Lab, Berlin, Germany
[3] Charite, Dept Neurol, D-13353 Berlin, Germany
关键词
OPTICAL COHERENCE TOMOGRAPHY; NERVE-FIBER LAYER; MULTIPLE-SCLEROSIS; GANGLION-CELL; PLEXIFORM LAYER; NEUROMYELITIS-OPTICA; SEGMENTATION; PATHOLOGY; NEURITIS; DISEASE;
D O I
10.1371/journal.pone.0137316
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose Measurement of intra-retinal layer thickness using optical coherence tomography (OCT) has become increasingly prominent in multiple sclerosis (MS) research. Nevertheless, the approaches used for determining the mean layer thicknesses vary greatly. Insufficient data exist on the reliability of different thickness estimates, which is crucial for their application in clinical studies. This study addresses this lack by evaluating the repeatability of different thickness estimates. Methods Studies that used intra-retinal layer segmentation of macular OCT scans in patients with MS were retrieved from PubMed. To investigate the repeatability of previously applied layer estimation approaches, we generated datasets of repeating measurements of 15 healthy subjects and 13 multiple sclerosis patients using two OCT devices (Cirrus HD-OCT and Spectralis SD-OCT). We calculated each thickness estimate in each repeated session and analyzed repeatability using intra-class correlation coefficients and coefficients of repeatability. Results We identified 27 articles, eleven of them used the Spectralis SD-OCT, nine Cirrus HD-OCT, two studies used both devices and two studies applied RTVue-100. Topcon OCT-1000, Stratus OCT and a research device were used in one study each. In the studies that used the Spectralis, ten different thickness estimates were identified, while thickness estimates of the Cirrus OCT were based on two different scan settings. In the simulation dataset, thickness estimates averaging larger areas showed an excellent repeatability for all retinal layers except the outer plexiform layer (OPL). Conclusions Given the good reliability, the thickness estimate of the 6 mm-diameter area around the fovea should be favored when OCT is used in clinical research. Assessment of the OPL was weak in general and needs further investigation before OPL thickness can be used as a reliable parameter.
引用
收藏
页数:16
相关论文
共 47 条
[21]   Retinal ganglion cell and inner plexiform layer thinning in clinically isolated syndrome [J].
Oberwahrenbrock, Timm ;
Ringelstein, Marius ;
Jentschke, Simon ;
Deuschle, Katrin ;
Klumbies, Katharina ;
Bellmann-Strobl, Judith ;
Harmel, Jens ;
Ruprecht, Klemens ;
Schippling, Sven ;
Hartung, Hans-Peter ;
Aktas, Orhan ;
Brandt, Alexander U. ;
Paul, Friedemann .
MULTIPLE SCLEROSIS JOURNAL, 2013, 19 (14) :1887-1895
[22]   Retinal Damage in Multiple Sclerosis Disease Subtypes Measured by High-Resolution Optical Coherence Tomography [J].
Oberwahrenbrock, Timm ;
Schippling, Sven ;
Ringelstein, Marius ;
Kaufhold, Falko ;
Zimmermann, Hanna ;
Keser, Nazmiye ;
Young, Kim Lea ;
Harmel, Jens ;
Hartung, Hans-Peter ;
Martin, Roland ;
Paul, Friedemann ;
Aktas, Orhan ;
Brandt, Alexander U. .
MULTIPLE SCLEROSIS INTERNATIONAL, 2012, 2012
[23]   IMPROVED VISUALIZATION OF HENLE FIBER LAYER BY CHANGING THE MEASUREMENT BEAM ANGLE ON OPTICAL COHERENCE TOMOGRAPHY [J].
Otani, Tomohiro ;
Yamaguchi, Yumiko ;
Kishi, Shoji .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (03) :497-501
[24]   Different phenotypes of the appearance of the outer plexiform layer on optical coherence tomography [J].
Ouyang, Yanling ;
Walsh, Alexander C. ;
Keane, Pearse A. ;
Heussen, Florian M. ;
Pappuru, Rajeev K. R. ;
Sadda, Srinivas R. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (10) :2311-2317
[25]   Analysis of spectral domain optical coherence tomography measurements in optic neuritis: differences in neuromyelitis optica, multiple sclerosis, isolated optic neuritis and normal healthy controls [J].
Park, Kyung-Ah ;
Kim, Jaeryung ;
Oh, Sei Yeul .
ACTA OPHTHALMOLOGICA, 2014, 92 (01) :E57-E65
[26]   Active MS is associated with accelerated retinal ganglion cell/inner plexiform layer thinning [J].
Ratchford, John N. ;
Saidha, Shiv ;
Sotirchos, Elias S. ;
Oh, Jiwon A. ;
Seigo, Michaela A. ;
Eckstein, Christopher ;
Durbin, Mary K. ;
Oakley, Jonathan D. ;
Meyer, Scott A. ;
Conger, Amy ;
Frohman, Teresa C. ;
Newsome, Scott D. ;
Balcer, Laura J. ;
Frohman, Elliot M. ;
Calabresi, Peter A. .
NEUROLOGY, 2013, 80 (01) :47-54
[27]   Photoreceptor Layer Thinning in Idiopathic Parkinson's Disease [J].
Roth, Nicolas M. ;
Saidha, Shiv ;
Zimmermann, Hanna ;
Brandt, Alexander U. ;
Isensee, Justine ;
Benkhellouf-Rutkowska, Agnieszka ;
Dornauer, Matthias ;
Kuehn, Andrea A. ;
Mueller, Thomas ;
Calabresi, Peter A. ;
Paul, Friedemann .
MOVEMENT DISORDERS, 2014, 29 (09) :1163-1170
[28]   Relationships Between Retinal Axonal and Neuronal Measures and Global Central Nervous System Pathology in Multiple Sclerosis [J].
Saidha, Shiv ;
Sotirchos, Elias S. ;
Oh, Jiwon ;
Syc, Stephanie B. ;
Seigo, Michaela A. ;
Shiee, Navid ;
Eckstein, Chistopher ;
Durbin, Mary K. ;
Oakley, Jonathan D. ;
Meyer, Scott A. ;
Frohman, Teresa C. ;
Newsome, Scott ;
Ratchford, John N. ;
Balcer, Laura J. ;
Pham, Dzung L. ;
Crainiceanu, Ciprian M. ;
Frohman, Elliot M. ;
Reich, Daniel S. ;
Calabresi, Peter A. .
JAMA NEUROLOGY, 2013, 70 (01) :34-43
[29]   Microcystic macular oedema, thickness of the inner nuclear layer of the retina, and disease characteristics in multiple sclerosis: a retrospective study [J].
Saidha, Shiv ;
Sotirchos, Elias S. ;
Ibrahim, Mohamed A. ;
Crainiceanu, Ciprian M. ;
Gelfand, Jeffrey M. ;
Sepah, Yasir J. ;
Ratchford, John N. ;
Oh, Jiwon ;
Seigo, Michaela A. ;
Newsome, Scott D. ;
Balcer, Laura J. ;
Frohman, Elliot M. ;
Green, Ari J. ;
Nguyen, Quan D. ;
Calabresi, Peter A. .
LANCET NEUROLOGY, 2012, 11 (11) :963-972
[30]   Visual dysfunction in multiple sclerosis correlates better with optical coherence tomography derived estimates of macular ganglion cell layer thickness than peripapillary retinal nerve fiber layer thickness [J].
Saidha, Shiv ;
Syc, Stephanie B. ;
Durbin, Mary K. ;
Eckstein, Christopher ;
Oakley, Jonathan D. ;
Meyer, Scott A. ;
Conger, Amy ;
Frohman, Teresa C. ;
Newsome, Scott ;
Ratchford, John N. ;
Frohman, Elliot M. ;
Calabresi, Peter A. .
MULTIPLE SCLEROSIS JOURNAL, 2011, 17 (12) :1449-1463