Sensors and biosensors for the determination of small molecule biological toxins

被引:45
作者
Wang, Xiang-Hong [1 ,2 ]
Wang, Shuo [1 ]
机构
[1] Tianjin Univ Sci & Technol, Minist Educ, Key Lab Food Nutr & Safety, Tianjin 300222, Peoples R China
[2] Agr Univ Hebei, Fac Food Sci & Technol, Baoding 071001, Hebei, Peoples R China
关键词
review; sensors; small molecule biological toxin;
D O I
10.3390/s8096045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The following review of sensors and biosensors focuses on the determination of commonly studied small molecule biological toxins, including mycotoxins and small molecule neurotoxins. Because of the high toxicity of small molecule toxins, an effective analysis technique for determining their toxicity is indispensable. Sensors and biosensors have emerged as sensitive and rapid techniques for toxicity analysis in the past decade. Several different sensors for the determination of mycotoxins and other small molecule neurotoxins have been reported in the literature, and many of these sensors such as tissue biosensors, enzyme sensors, optical immunosensors, electrochemical sensors, quartz crystal sensors, and surface plasmon resonance biosensors are reviewed in this paper. Sensors are a practical and convenient monitoring tool in the area of routine analysis, and their specificity, sensitivity, reproducibility and analysis stability should all be improved in future work. In addition, accuracy field portable sensing devices and multiplexing analysis devices will be important requirement for the future.
引用
收藏
页码:6045 / 6054
页数:10
相关论文
共 33 条
[1]   Development of immunosensor based on OWLS technique for determining Aflatoxin B1 and Ochratoxin A [J].
Adanyi, N. ;
Levkovets, I. A. ;
Rodriguez-Gil, S. ;
Ronald, A. ;
Varadi, M. ;
Szendro, I. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (06) :797-802
[2]   Monoclonal antibody based electrochemical immunosensor for the determination of ochratoxin A in wheat [J].
Alarcon, Sergio Hugo ;
Palleschi, Giuseppe ;
Compagnone, Dario ;
Pascale, Michelangelo ;
Visconti, Angelo ;
Barna-Vetro, Ildiko .
TALANTA, 2006, 69 (04) :1031-1037
[3]  
Andreone Franco, 2006, Acta Herpetologica, V1, P15
[4]  
ANGELO V, 1998, J CHROMATOGR A, V815, P133
[5]   Enzyme sensor for the electrochemical detection of the marine toxin okadaic acid [J].
Campas, Monica ;
Marty, Jean-Louis .
ANALYTICA CHIMICA ACTA, 2007, 605 (01) :87-93
[6]   An automated, handheld biosensor for aflatoxin [J].
Carlson, MA ;
Bargeron, CB ;
Benson, RC ;
Fraser, AB ;
Phillips, TE ;
Velky, JT ;
Groopman, JD ;
Strickland, PT ;
Ko, HW .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11) :841-848
[7]  
Carter RM, 1997, ANAL LETT, V30, P1465, DOI 10.1080/00032719708001668
[8]   Development of an ultra high sensitive tissue biosensor for determination of swellfish poisoning, tetrodotoxin [J].
Cheun, B ;
Endo, H ;
Hayashi, T ;
Nagashima, Y ;
Watanabe, E .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (12) :1185-1191
[9]   Use of a channel biosensor for the assay of paralytic shellfish toxins [J].
Cheun, BS ;
Loughran, M ;
Hayashi, T ;
Nagashima, Y ;
Watanabe, E .
TOXICON, 1998, 36 (10) :1371-1381
[10]  
DMello J. P. F., 2003, FOOD SAFETY CONTAMIN