Development and evaluation of a semi-automatic 3D segmentation technique of the carotid arteries from 3D ultrasound images

被引:6
作者
Gill, JD [1 ]
Ladak, HM [1 ]
Steinman, DA [1 ]
Fenster, A [1 ]
机构
[1] John P Robarts Res Inst, London, ON N6A 5K8, Canada
来源
MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2 | 1999年 / 3661卷
关键词
3-D ultrasonography; image segmentation; deformable models; atherosclerosis;
D O I
10.1117/12.348576
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, we report on a semi-automatic approach to segmentation of carotid arteries from 3D ultrasound (US) images. Our method uses a deformable model which first is rapidly inflated to approximately find the boundary of the artery, then is further deformed using image-based forces to better localize the boundary. An operator is required to initialize the model by selecting a position in the 3D US image, which is within the carotid vessel. Since the choice of position is user-defined, and therefore arbitrary, there is an inherent variability in the position and shape of the final segmented boundary. We have assessed the performance of our segmentation method by examining the local variability in boundary shape as the initial selected position is varied in a freehand 3D US image of a human carotid bifurcation. Our results indicate that high variability in boundary position occurs in regions where either the segmented boundary is highly curved, or the 3D US image has poorly defined vessel edges.
引用
收藏
页码:214 / 221
页数:8
相关论文
共 12 条
[1]  
Bouma CJ, 1996, LECT NOTES COMPUT SC, V1131, P203, DOI 10.1007/BFb0046955
[2]   Automatic calculation of total lung capacity from automatically traced lung boundaries in postero-anterior and lateral digital chest radiographs [J].
Carrascal, FM ;
Carreira, JM ;
Souto, M ;
Tahoces, PG ;
Gomez, L ;
Vidal, JJ .
MEDICAL PHYSICS, 1998, 25 (07) :1118-1131
[3]   DESCRIPTION OF COMPLEX OBJECTS FROM MULTIPLE RANGE IMAGES USING AN INFLATING BALLOON MODEL [J].
CHEN, Y ;
MEDIONI, G .
COMPUTER VISION AND IMAGE UNDERSTANDING, 1995, 61 (03) :325-334
[4]   A FULLY AUTOMATED ALGORITHM FOR THE SEGMENTATION OF LUNG FIELDS ON DIGITAL CHEST RADIOGRAPHIC IMAGES [J].
DURYEA, J ;
BOONE, JM .
MEDICAL PHYSICS, 1995, 22 (02) :183-191
[5]  
FENSTER A, 1996, IEEE ENG MED BIOL, V15
[6]  
GORELICK PB, 1994, STROKE, V25, P1581
[7]  
McInerney T, 1996, Med Image Anal, V1, P91, DOI 10.1016/S1361-8415(96)80007-7
[8]   Freehand three-dimensional ultrasound: Implementation and applications [J].
Sherebrin, S ;
Fenster, A ;
Rankin, R ;
Spence, D .
PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 :296-303
[9]  
TAYLOR DW, 1991, NEW ENGL J MED, V325, P445
[10]  
Terzopoulos D., 1991, Proceedings 1991 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (91CH2983-5), P70, DOI 10.1109/CVPR.1991.139663