Optimal temperature between high and low stage cycles for R134a/R410A cascade heat pump based water heater system

被引:60
作者
Kim, Dong Ho [1 ]
Park, Han Saem [1 ]
Kim, Min Soo [1 ]
机构
[1] Seoul Natl Univ, Sch Mech & Aerosp Engn, Div WCU Multiscale Mech Design, Seoul 151744, South Korea
关键词
AWHP (air-to-water heat pump); Cascade; Optimum; Intermediate temperature; R134a; R410A; REFRIGERATION SYSTEM; COOLING APPLICATIONS; OPTIMIZATION; CO2;
D O I
10.1016/j.expthermflusci.2013.01.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
Single-stage air-source heat pumps have some disadvantages such as a deteriorated heating capacity and low coefficient of performance at low ambient temperatures. To overcome these disadvantages, a cascade cycle has been suggested; this cycle exhibits a better performance at low ambient temperatures. Many studies have investigated the cascade heat pump system. However, little information is available regarding experimental verification of the optimal intermediate temperature levels based on experimental results. In this study, an AWHP (air-to-water heat pump) was studied numerically and experimentally. The high and low cycles of the AWHP adopted R134a and R410A as refrigerants, respectively. Numerical analysis of the optimal intermediate temperature was performed and the experiment was conducted under various operating conditions: ambient temperature, condenser water inlet temperature, and heating capacity. The numerically optimized intermediate temperature accurately predicted the experimental data. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:172 / 179
页数:8
相关论文
共 16 条
[1]   Optimization of two-stage transcritical carbon dioxide heat pump cycles [J].
Agrawal, Neeraj ;
Bhattacharyya, Souvik ;
Sarkar, J. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2007, 46 (02) :180-187
[2]   Experimental evaluation of a cascade refrigeration system prototype with CO2 and NH3 for freezing process applications [J].
Alberto Dopazo, J. ;
Fernandez-Seara, Jose .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (01) :257-267
[3]  
Bansal P.K., 2007, ASHRAE T, V113, P245
[4]   Two-stage air-source heat pump for residential heating and cooling applications in northern US climates [J].
Bertsch, Stefan S. ;
Groll, Eckhard A. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (07) :1282-1292
[5]   CO2-C3H8 cascade refrigeration-heat pump system: Heat exchanger inventory optimization and its numerical verification [J].
Bhattacharyya, Souvik ;
Mukhopadhyay, S. ;
Sarkar, J. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (07) :1207-1213
[6]  
BINGMING W, 2009, INT J REFRIG, V32, P1358, DOI DOI 10.1016/J.IJREFRIG.2009.03.008
[7]   Performance evaluation of a two-stage CO2 cycle with gas injection in the cooling mode operation [J].
Cho, Honghyun ;
Baek, Changhyun ;
Park, Chasik ;
Kim, Yongchan .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (01) :40-46
[8]   Advances in heat pump systems: A review [J].
Chua, K. J. ;
Chou, S. K. ;
Yang, W. M. .
APPLIED ENERGY, 2010, 87 (12) :3611-3624
[9]   Theoretical analysis of a CO2-NH3 cascade refrigeration system for cooling applications at low temperatures [J].
Dopazo, J. Alberto ;
Fernandez-Seara, Jose ;
Sieres, Jaime ;
Uhia, Francisco J. .
APPLIED THERMAL ENGINEERING, 2009, 29 (8-9) :1577-1583
[10]   OPTIMUM TEMPERATURE STAGING OF CRYOGENIC REFRIGERATION SYSTEM [J].
JEONG, S ;
SMITH, JL .
CRYOGENICS, 1994, 34 (11) :929-933