Highly Sensitive and Selective Photoelectrochemical Aptasensor for Cancer Biomarker CA125 Based on AuNPs/GaN Schottky Junction

被引:81
作者
Hu, Danli [1 ]
Liang, Hongfeng [2 ]
Wang, Xinyang [1 ]
Luo, Fang [3 ]
Qiu, Bin [1 ]
Lin, Zhenyu [1 ]
Wang, Jian [1 ]
机构
[1] Fuzhou Univ, Coll Chem, Fujian Prov Key Lab Anal & Detect Food Safety, Minist Educ,Key Lab Analyt Sci Food Safety & Biol, Fuzhou 350116, Fujian, Peoples R China
[2] Yangjiang Peoples Hosp, Yangjiang, Guangdong, Peoples R China
[3] Fuzhou Univ, Coll Biol Sci & Engn, Fuzhou 350116, Fujian, Peoples R China
关键词
AU NANOPARTICLES; TIO2; NANOTUBES; ELECTROCATALYSIS; NANORODS;
D O I
10.1021/acs.analchem.0c02117
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A gold nanoparticle (AuNPs)/gallium nitride (GaN) Schottky junction was fabricated by growing AuNPs in situ on the surface of GaN and then etched by H2O2 to appropriate diameter. The photogenerated electrons of GaN can be captured and transferred by the AuNPs to increase the migration efficiency, and the electron-hole pairs were separated, which results in the enhancement of the photoelectric performance of the system. The Fermi energy level of AuNPs and the charge transfer efficiency of the AuNPs/GaN can be adjusted by controlling the size of the AuNPs. Then the AuNPs/GaN Schottky photoelectrode had been applied to develop a novel photoelectrochemical (PEC) aptasensor for the epithelial ovarian cancer marker-CA125 detection. The DNA aptamer of CA125 was modified on the surface of the AuNPs via Au-S bonds. The aptamer can bind with the target with high selectivity, and the photoelectron transfer process of the system can be blocked by the protein, which results in the decrease of the photocurrent of the system. The ratio of photocurrent before and after incubation with CA125 (I-1/I-0) has a linear with the concentration of CA125 in the range of 1-100 U/mL with a detection limit of 0.3 U/mL. The standard addition recovery rates were between 86.01% and 90.09%. This method showed good sensitivity, selectivity, and reliability in detecting CA125 in serum.
引用
收藏
页码:10114 / 10120
页数:7
相关论文
共 42 条
[1]   Dual detection of cancer biomarker CA125 using absorbance and electrochemical methods [J].
Al-Ogaidi, Israa ;
Aguilar, Zoraida P. ;
Suri, Savan ;
Gou, Honglei ;
Wu, Nianqiang .
ANALYST, 2013, 138 (19) :5647-5653
[2]   An antenna/spacer/reflector based Au/BiVO4/WO3/Au nanopatterned photoanode for plasmon-enhanced photoelectrochemical water splitting [J].
Chen, Bin ;
Zhang, Zhuo ;
Baek, Minki ;
Kim, Sangkuk ;
Kim, Wooyul ;
Yong, Kijung .
APPLIED CATALYSIS B-ENVIRONMENTAL, 2018, 237 :763-771
[3]   Ultrasensitive Photoelectrochemical Immunoassay for Matrix Metalloproteinase-2 Detection Based on CdS:Mn/CdTe Cosensitized TiO2 Nanotubes and Signal Amplification of SiO2@Ab2 Conjugates [J].
Fan, Gao-Chao ;
Han, Li ;
Zhu, Hua ;
Zhang, Jian-Rong ;
Zhu, Jun-Jie .
ANALYTICAL CHEMISTRY, 2014, 86 (24) :12398-12405
[4]   Highly Selective and Sensitive Photoelectrochemical Sensing Platform for VEGF165 Assay Based on the Switching of Photocurrent Polarity of CdS QDs by Porous Cu2O-CuO Flower [J].
Fu, Yamin ;
Zou, Kang ;
Liu, Mengyue ;
Zhang, Xiaohua ;
Du, Cuicui ;
Chen, Jinhua .
ANALYTICAL CHEMISTRY, 2020, 92 (01) :1189-1196
[5]   Prereduction-promoted enhanced growth of silver nanoparticles for ultrasensitive colorimetric detection of alkaline phosphatase and carbohydrate antigen 125 [J].
Gao, Jing ;
Jia, Minna ;
Xu, Yingying ;
Zheng, Jimin ;
Shao, Na ;
Zhao, Meiping .
TALANTA, 2018, 189 :129-136
[6]   Plasmonic hot charge carriers activated Ni centres of metal- organic frameworks for the oxygen evolution reaction [J].
Hu, Wen-Chao ;
Shi, Yi ;
Zhou, Yue ;
Wang, Chao ;
Younis, Muhammad Rizwan ;
Pang, Jie ;
Wang, Chen ;
Xia, Xing-Hua .
JOURNAL OF MATERIALS CHEMISTRY A, 2019, 7 (17) :10601-10609
[7]   Aptamer and 5-fluorouracil dual-loading Ag2S quantum dots used as a sensitive label-free probe for near-infrared photoluminescence turn-on detection of CA125 antigen [J].
Jin, Hui ;
Gui, Rijun ;
Gong, Jun ;
Huang, Wenxue .
BIOSENSORS & BIOELECTRONICS, 2017, 92 :378-384
[8]   XPS characterization of Au/TiO2 catalysts: Binding energy assessment and irradiation effects [J].
Kruse, Norbert ;
Chenakin, Sergey .
APPLIED CATALYSIS A-GENERAL, 2011, 391 (1-2) :367-376
[9]   Enhanced Electrocatalysis via Boosted Separation of Hot Charge Carriers of Plasmonic Gold Nanoparticles Deposited on Reduced Graphene Oxide [J].
Liao, Xue-Wei ;
Wang, Shan-Shan ;
Xu, Gui-Yin ;
Wang, Chen .
CHEMELECTROCHEM, 2019, 6 (05) :1419-1426
[10]   CdSe quantum dot-sensitized Au/TiO2 hybrid mesoporous films and their enhanced photoelectrochemical performance [J].
Liu, Liping ;
Wang, Gongming ;
Li, Yat ;
Li, Yadong ;
Zhang, Jin Z. .
NANO RESEARCH, 2011, 4 (03) :249-258