Physiological effects of different interfaces during noninvasive ventilation for acute respiratory failure

被引:59
作者
Fraticelli, Amanda Tarabini [1 ]
Lellouche, Francois [1 ,2 ,4 ]
L'Her, Erwan [1 ]
Taille, Solenne [1 ]
Mancebo, Jordi [5 ]
Brochard, Laurent [1 ,2 ,3 ]
机构
[1] Grp Hosp Albert Chenevier Henri Mondor, AP HP, Serv Reanimat Med, Creteil, France
[2] Univ Paris, Creteil, France
[3] Hop Henri Mondor, INSERM, U955, F-94010 Creteil, France
[4] Univ Laval, Hop Laval, Ctr Rech, Quebec City, PQ, Canada
[5] Hosp Santa Creu & Sant Pau, Serv Med Intens, Barcelona, Spain
关键词
interfaces/masks; noninvasive ventilation; acute respiratory failure; patient-ventilator asynchrony; dead space; POSITIVE-PRESSURE VENTILATION; OBSTRUCTIVE PULMONARY-DISEASE; CONVENTIONAL MECHANICAL VENTILATION; SUPPORT VENTILATION; ACUTE EXACERBATIONS; MOISTURE EXCHANGERS; SYSTEM BIPAP; FACE MASK; SUCCESS; WORK;
D O I
10.1097/CCM.0b013e31819b575f
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To test the short-term physiologic effects (indexes of respiratory effort, ventilation, and gas exchange), leaks, patient-ventilator asynchrony, and comfort of four noninvasive ventilation (NIV) facial, oronasal, or oral interfaces with major differences in internal volume. Design: Prospective, short-term, crossover randomized physiologic study. Setting: Medical intensive care unit in a university hospital. Patients and Participants. Fourteen consecutive patients receiving NIV for either hypoxemic (n = 7) or hypercapnic (n = 7) acute respiratory failure. Interventions. Four interfaces, tested randomly over consecutive sequences, had very high (977 mL), high (163 mL), moderate (84 mL), or virtually no internal volume (mouthpiece). The pressure level was increased in two patients with the larger mask, and was decreased in all patients when using the mouthpiece. Measurements and Main Results. Despite differences in internal volume, no apparent dead space effect was observed on minute ventilation, work of breathing, or arterial CO, levels. Compared with baseline, NIV was uniformly successful in reducing indexes of respiratory effort: the pressure-time product of the respiratory muscles decreased from a median (25th-75th inter-quartile range) of 179 (158-285) cm H2O.sec.min(-1) to values between 91 and 111 during NIV, with no differences between masks (p = 0.84). Few differences were observed in terms of arterial blood gases and breathing pattern. Leaks and patient-ventilator asynchronies were greater with the mouthpiece, and comfort with this interface was deemed poor for most patients. Conclusion. The internal volume of the masks had no apparent short-term dead space effect on gas exchange, minute ventilation, or patient's effort, suggesting that, with the exception of mouthpiece, interfaces may be interchangeable in clinical practice provided adjustment of the ventilatory device parameters are performed. (Crit Care Med 2009; 37:939-945)
引用
收藏
页码:939 / 945
页数:7
相关论文
共 41 条
  • [1] NONINVASIVE MECHANICAL VENTILATION IN ACUTE RESPIRATORY-FAILURE DUE TO CHRONIC OBSTRUCTIVE PULMONARY-DISEASE - CORRELATES FOR SUCCESS
    AMBROSINO, N
    FOGLIO, K
    RUBINI, F
    CLINI, E
    NAVA, S
    VITACCA, M
    [J]. THORAX, 1995, 50 (07) : 755 - 757
  • [2] Predicting the result of noninvasive ventilation in severe acute exacerbations of patients with chronic airflow limitation
    Antón, A
    Güell, R
    Gómez, J
    Serrano, J
    Castellano, A
    Carrasco, JL
    Sanchis, J
    [J]. CHEST, 2000, 117 (03) : 828 - 833
  • [3] Anton Antonio, 2003, Respir Care, V48, P922
  • [4] Predictors of failure of noninvasive positive pressure ventilation in patients with acute hypoxemic respiratory failure: a multi-center study
    Antonelli, M
    Conti, G
    Moro, ML
    Esquinas, A
    Gonzalez-Diaz, G
    Confalonieri, M
    Pelaia, P
    Principi, T
    Gregoretti, C
    Beltrame, F
    Pennisi, MA
    Arcangeli, A
    Proietti, R
    Passariello, M
    Meduri, GU
    [J]. INTENSIVE CARE MEDICINE, 2001, 27 (11) : 1718 - 1728
  • [5] A comparison of noninvasive positive-pressure ventilation and conventional mechanical ventilation in patients with acute respiratory failure
    Antonelli, M
    Conti, G
    Rocco, M
    Bufi, M
    De Blasi, RA
    Vivino, G
    Gasparetto, A
    Meduri, GU
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (07) : 429 - 435
  • [6] Noninvasive ventilation reduces mortality in acute respiratory failure following lung resection
    Auriant, I
    Jallot, A
    Hervé, P
    Cerrina, J
    Ladurie, FL
    Fournier, JL
    Lescot, B
    Parquin, F
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (07) : 1231 - 1235
  • [7] Amyotrophic lateral sclerosis - Prolongation of life by noninvasive respiratory aids
    Bach, JR
    [J]. CHEST, 2002, 122 (01) : 92 - 98
  • [8] INTERMITTENT POSITIVE PRESSURE VENTILATION VIA THE MOUTH AS AN ALTERNATIVE TO TRACHEOSTOMY FOR 257 VENTILATOR USERS
    BACH, JR
    ALBA, AS
    SAPORITO, LR
    [J]. CHEST, 1993, 103 (01) : 174 - 182
  • [9] NONINVASIVE VENTILATION FOR ACUTE EXACERBATIONS OF CHRONIC OBSTRUCTIVE PULMONARY-DISEASE
    BROCHARD, L
    MANCEBO, J
    WYSOCKI, M
    LOFASO, F
    CONTI, G
    RAUSS, A
    SIMONNEAU, G
    BENITO, S
    GASPARETTO, A
    LEMAIRE, F
    ISABEY, D
    HARF, A
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1995, 333 (13) : 817 - 822
  • [10] Patient-ventilator asynchrony during noninvasive ventilation: the role of expiratory trigger
    Calderini, E
    Confalonieri, M
    Puccio, PG
    Francavilla, N
    Stella, L
    Gregoretti, C
    [J]. INTENSIVE CARE MEDICINE, 1999, 25 (07) : 662 - 667