Evaluating the impact of extended field-of-view CT reconstructions on CT values and dosimetric accuracy for radiation therapy

被引:16
作者
Cheung, Joey P. [1 ,3 ]
Shugard, Erin [1 ,4 ]
Mistry, Nilesh [2 ]
Pouliot, Jean [1 ]
Chen, Josephine [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
[2] Siemens Healthcare USA, Malvern, PA 19355 USA
[3] Sutter Hlth Mills Peninsula Med Ctr, Dept Radiat Oncol, San Mateo, CA 94401 USA
[4] Kaiser Permanente Oakland, Dept Radiat Oncol, 3701 Broadway, Oakland, CA 94611 USA
关键词
CT simulation; extended field of view; radiation therapy; treatment planning; QUALITY-ASSURANCE; DOSE CALCULATIONS; RADIOTHERAPY; ALGORITHM; SCANNER; NUMBER;
D O I
10.1002/mp.13299
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeWide bore CT scanners use extended field-of-view (eFOV) reconstruction algorithms to attempt to recreate tissue truncated due to large patient habitus. Radiation therapy planning systems rely on accurate CT numbers in order to correctly plan and calculate radiation dose. This study looks at the impact of eFOV reconstructions on CT numbers and radiation dose calculations in real patient geometries. MethodsA large modular phantom based on real patient geometries was created to surround a CIRS Model 062M phantom. The modular sections included a smooth patient surface, a skin fold in the patient surface, and the addition of arms for simulation of the patient in arms up or arms down position. This phantom was used to evaluate the accuracy of CT numbers for three extended FOV algorithms implemented on Siemens CT scanners: eFOV, HDFOV, and HDProFOV. Six different configurations of the phantoms were scanned and images were reconstructed for the three different extended FOV algorithms. The CIRS phantom inserts and overall phantom geometry were contoured in each image, and the Hounsfield units (HU) numbers were compared to an image of the phantom within the standard scan FOV (sFOV) without the modular sections. To evaluate the effect on dose calculations, six radiotherapy patients previously treated at our institution (three head and neck and three chest/pelvis) whose body circumferences extended past the 50cm sFOV in the treatment planning CT were used. Images acquired on a Siemens Sensation Open scanner were reconstructed using sFOV, eFOV and HDFOV algorithms. A physician and dosimetrist identified the radiation target, critical organs, and external patient contour. A benchmark CT was created for each patient, consisting of an average of the 3 CT reconstructions with a density override applied to regions containing truncation artifacts. The benchmark CT was used to create an optimal radiation treatment plan. The plan was copied onto each CT reconstruction without density override and dose was recalculated. ResultsTissue extending past the sFOV impacts the HU numbers for tissues inside and outside the sFOV when using extended FOV reconstructions. On average, the HU for all CIRS density inserts in the arms up (arms down) position varied by 43HU (67HU), 39HU (73HU), and 18HU (51HU) for the eFOV, HDFOV, and HDProFOV scans, respectively. In the patient dose calculations, patients with a smooth patient contour had the least deviation from the benchmark in the HDFOV (0.1-0.5%) compared to eFOV (0.4-1.8%) reconstructions. In cases with large amounts of tissue and irregular skin folds, the eFOV deviated the least from the benchmark (range 0.2-0.6% dose difference) compared to HDFOV (range 1.3-1.8% dose difference). ConclusionsAll reconstruction algorithms demonstrated good CT number accuracy in the center of the image. Larger artifacts are seen near and extending outside the scan FOV, however, dose calculations performed using typical beam arrangements using the extended FOV reconstructions were still mostly within 2.5% of best estimated reference values.
引用
收藏
页码:892 / 901
页数:10
相关论文
共 17 条
[1]   An assessment of image distortion and CT number accuracy within a wide-bore CT extended field of view [J].
Beeksma, B. ;
Truant, D. ;
Holloway, L. ;
Arumugam, S. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (02) :255-261
[2]   Applications of simulator computed tomography number for photon dose calculations during radiotherapy treatment planning [J].
Chu, JCH ;
Ni, B ;
Kriz, R ;
Saxena, VA .
RADIOTHERAPY AND ONCOLOGY, 2000, 55 (01) :65-73
[3]   Assessment of the variation in CT scanner performance (image quality and Hounsfield units) with scan parameters, for image optimisation in radiotherapy treatment planning [J].
Davis, Anne T. ;
Palmer, Antony L. ;
Pani, Silvia ;
Nisbet, Andrew .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 :59-64
[4]   Can CT scan protocols used for radiotherapy treatment planning be adjusted to optimize image quality and patient dose? A systematic review [J].
Davis, Anne T. ;
Palmer, Antony L. ;
Nisbet, Andrew .
BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1076)
[5]   USE OF CT SCANNERS IN MEGAVOLTAGE PHOTON-BEAM THERAPY PLANNING [J].
GEISE, RA ;
MCCULLOUGH, EC .
RADIOLOGY, 1977, 124 (01) :133-141
[6]   A novel reconstruction algorithm to extend the CT scan field-of-view [J].
Hsieh, J ;
Chao, E ;
Thibault, J ;
Grekowicz, B ;
Horst, A ;
McOlash, S ;
Myers, TJ .
MEDICAL PHYSICS, 2004, 31 (09) :2385-2391
[7]   THE USE OF COMPUTED-TOMOGRAPHY NUMBERS IN DOSE CALCULATIONS FOR RADIATION-THERAPY [J].
HUIZENGA, H ;
STORCHI, PRM .
ACTA RADIOLOGICA ONCOLOGY, 1985, 24 (06) :509-519
[8]   Tolerance levels for quality assurance of electron density values generated from CT in radiotherapy treatment planning [J].
Kilby, W ;
Sage, J ;
Rabett, V .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (09) :1485-1492
[9]   An enhanced reconstruction algorithm to extend CT scan field-of-view with z-axis consistency constraint [J].
Li, Baojun ;
Deng, Junjun ;
Lonn, Albert H. ;
Hsieh, Jiang .
MEDICAL PHYSICS, 2012, 39 (10) :6028-6034
[10]   Quality assurance for computed-tomography simulators and the computedtomography-simulation process: Report of the AAPM radiation therapy committee task group no. 66 [J].
Mutic, S ;
Palta, JR ;
Butker, EK ;
Das, IJ ;
Huq, MS ;
Loo, LND ;
Salter, BJ ;
McCollough, CH ;
Van Dyk, J .
MEDICAL PHYSICS, 2003, 30 (10) :2762-2792