Transcranial Doppler ultrasound to assess cerebrovascular reactivity: reliability, reproducibility and effect of posture

被引:42
作者
McDonnell, Michelle N. [1 ]
Berry, Narelle M. [2 ]
Cutting, Mark A. [2 ]
Keage, Hannah A. [3 ]
Buckley, Jonathan D. [2 ]
Howe, Peter R. C. [2 ]
机构
[1] Univ S Australia, Sch Hlth Sci, Adelaide, SA 5001, Australia
[2] Univ S Australia, Nutr Physiol Res Ctr, Adelaide, SA 5001, Australia
[3] Univ S Australia, Sch Psychol Social Work & Social Policy, Adelaide, SA 5001, Australia
来源
PEERJ | 2013年 / 1卷
基金
英国医学研究理事会;
关键词
Reliability; Reproducibility; Cerebrovascular reactivity; Posture; Doppler ultrasound;
D O I
10.7717/peerj.65
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Transcranial Doppler ultrasound (TCD) allows measurement of blood flow velocities in the intracranial vessels, and can be used to assess cerebral vasodilator responses to a hypercapnic stimulus. The reliability of this technique has not been established, nor is there agreement about whether the technique should be performed in sitting or lying postures. We tested the intra-and inter-rater reliability of measures of cerebrovascular reactivity (CVR) in 10 healthy adults, in sitting and lying postures. Participants underwent triplicate bilateral ultrasound assessment of flow velocities in the middle cerebral arteries whilst sitting and lying supine prior to and during inhalation of Carbogen (5% CO2, 95% O-2) for 2 min. This procedure was performed twice by each of two raters for a total of four sessions. CVR was calculated as the difference between baseline and the peak blood flow velocity attained during CO2 inhalation. Intraclass correlation coefficients (ICCs) for intra-rater reliability were greater sitting than lying for both raters (e. g. Rater 1 ICC sitting = 0.822, lying = 0.734), and inter-rater reliability was also greater in sitting (e. g. sitting ICC = 0.504, lying = 0.081). These results suggest that assessment of CVR using TCD should be performed with participants sitting in order to maximise CVR measurement reliability.
引用
收藏
页数:11
相关论文
共 28 条
[1]   NON-INVASIVE TRANSCRANIAL DOPPLER ULTRASOUND RECORDING OF FLOW VELOCITY IN BASAL CEREBRAL-ARTERIES [J].
AASLID, R ;
MARKWALDER, TM ;
NORNES, H .
JOURNAL OF NEUROSURGERY, 1982, 57 (06) :769-774
[2]   Integration of cerebrovascular CO2 reactivity and chemoreflex control of breathing: mechanisms of regulation, measurement, and interpretation [J].
Ainslie, Philip N. ;
Duffin, James .
AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2009, 296 (05) :R1473-R1495
[3]   Reliability of dynamic cerebral autoregulation measurement using spontaneous fluctuations in blood pressure [J].
Brodie, Fiona G. ;
Atkins, Emily R. ;
Robinson, Thompson G. ;
Panerai, Ronney B. .
CLINICAL SCIENCE, 2009, 116 (5-6) :513-520
[4]   CEREBRAL VASOREACTIVITY ASSESSED WITH TRANSCRANIAL DOPPLER AND REGIONAL CEREBRAL BLOOD-FLOW MEASUREMENTS - DOSE, SERUM CONCENTRATION, AND TIME-COURSE OF THE RESPONSE TO ACETAZOLAMIDE [J].
DAHL, A ;
RUSSELL, D ;
ROOTWELT, K ;
NYBERGHANSEN, R ;
KERTY, E .
STROKE, 1995, 26 (12) :2302-2306
[5]   REPEATABILITY OF TRANSCRANIAL DOPPLER MEASUREMENTS OF ARTERIAL BLOOD-FLOW VELOCITIES IN HEALTHY-SUBJECTS [J].
DEMOLIS, P ;
CHALON, S ;
GIUDICELLI, JF .
CLINICAL SCIENCE, 1993, 84 (06) :599-604
[6]  
Du Boulay G H, 1971, Proc R Soc Med, V64, P77
[7]   CEREBRAL ARTERIAL REACTIVITY AND SPASM AFTER SUBARACHNOID HEMORRHAGE [J].
DUBOULAY, G ;
DORSCH, N ;
SYMON, L ;
SHAH, S ;
ACKERMAN, R .
PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1972, 65 (01) :80-&
[8]   CEREBRAL ARTERIAL DIAMETERS DURING CHANGES IN BLOOD-PRESSURE AND CARBON-DIOXIDE DURING CRANIOTOMY [J].
GILLER, CA ;
BOWMAN, G ;
DYER, H ;
MOOTZ, L ;
KRIPPNER, W ;
LOFTUS, CM ;
MUIZELAAR, JP .
NEUROSURGERY, 1993, 32 (05) :737-742
[9]   Precision of Cerebrovascular Reactivity Assessment with Use of Different Quantification Methods for Hypercapnia Functional MR Imaging [J].
Goode, S. D. ;
Krishan, S. ;
Alexakis, C. ;
Mahajan, R. ;
Auer, D. P. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (05) :972-977
[10]  
Harrer J U, 2011, Ultraschall Med, V32 Suppl 1, pS95, DOI 10.1055/s-0029-1245369