Disposable amperometric magneto-immunosensor for direct detection of tetracyclines antibiotics residues in milk

被引:106
作者
Conzuelo, Felipe [1 ]
Gamella, Maria [1 ]
Campuzano, Susana [1 ]
Julio Reviejo, A. [1 ]
Pingarron, Jose M. [1 ]
机构
[1] Univ Complutense Madrid, Dept Quim Analit, Fac CC Quim, E-28040 Madrid, Spain
关键词
Tetracycline antibiotics; Magnetic beads; Milk; Screen-printed carbon electrodes; LINKED-IMMUNOSORBENT-ASSAY; ELECTROCHEMICAL IMMUNOSENSOR; SENSITIVE IMMUNOASSAY; SAMPLES; BEADS; HONEY;
D O I
10.1016/j.aca.2012.05.051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The preparation and performance of a disposable amperometric magneto-immunosensor, involving the use of a selective capture antibody immobilized on the surface of protein G-functionalized magnetic beads (ProtG-MBs) and screen-printed carbon electrodes (SPCEs), for the specific detection and quantification of tetracyclines (TCs) residues in milk is reported. A direct competitive immunoassay using a tracer with horseradish peroxidase (HRP) for the enzymatic labeling was performed. The amperometric response measured at -0.2 V vs. the silver pseudo-reference electrode of the SPCE upon the addition of H2O2 in the presence of hydroquinone (HQ) as redox mediator was used as transduction signal. The developed methodology showed very low limits of detection (in the low ppb level) for 4 tetracycline antibiotics tested in untreated milk samples, and a good selectivity against other antibiotic residues frequently detected in milk and dairy products. The usefulness of the magneto-immunosensor was demonstrated by analyzing UHT whole milk samples spiked with 44 ng mL(-1) tetracycline (TC) as well as a reference milk containing a certified oxytetracycline (OTC) content. These features, together with the short analysis time (30 min), the simplicity, and easy automation and miniaturization of the required instrumentation make the developed methodology a promising alternative in the development of devices for on-site analysis. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:29 / 36
页数:8
相关论文
共 26 条
[1]   Wavelength-interrogated optical biosensor for multi-analyte screening of sulfonamide, fluoroquinolone, β-lactam and tetracycline antibiotics in milk [J].
Adrian, Javier ;
Pasche, Stephanie ;
Pinacho, Daniel G. ;
Font, Hector ;
Diserens, Jean-Marc ;
Sanchez-Baeza, Francisco ;
Granier, Benoit ;
Voirin, Guy ;
Marco, M. -Pilar .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2009, 28 (06) :769-777
[2]   Complexities in tetracycline analysis - chemistry, matrix extraction, cleanup, and liquid chromatography [J].
Anderson, CR ;
Rupp, HS ;
Wu, WH .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1075 (1-2) :23-32
[3]  
[Anonymous], 2009, OFF J EUR UNION L, V15
[4]   The structural basis for the action of the antibiotics tetracycline, pactamycin, and hygromycin B on the 30S ribosomal subunit [J].
Brodersen, DE ;
Clemons, WM ;
Carter, AP ;
Morgan-Warren, RJ ;
Wimberly, BT ;
Ramakrishnan, V .
CELL, 2000, 103 (07) :1143-1154
[5]   Improvement of analytical performances of a disposable electrochemical immunosensor by using magnetic beads [J].
Centi, S. ;
Laschi, S. ;
Mascini, M. .
TALANTA, 2007, 73 (02) :394-399
[6]   Immunochemical determination of oxytetracycline in fish: Comparison between enzymatic and time-resolved fluorometric assays [J].
Chafer-Pericas, Consuelo ;
Maquieira, Angel ;
Puchades, Rosa ;
Miralles, Javier ;
Moreno, Amelia ;
Pastor-Navarro, Nuria ;
Espinos, Francisco .
ANALYTICA CHIMICA ACTA, 2010, 662 (02) :177-185
[7]   Immunomagnetic separation and MS/SPR end-detection combined procedure for rapid detection of Staphylococcus aureus and protein A [J].
Chen, Lingli ;
Deng, Le ;
Liu, Linlin ;
Peng, Zhihui .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) :1487-1492
[8]   Dependence of heme accessibility in horseradish peroxidase on Ca2+ [J].
Coates, AI ;
Cook, MP ;
Feezor, R ;
Schuh, MD .
JOURNAL OF INORGANIC BIOCHEMISTRY, 1998, 72 (1-2) :63-69
[9]   Quantitative detection of tetracycline residues in honey by a simple sensitive immunoassay [J].
Jeon, Moonsun ;
Paeng, Insook Rhee .
ANALYTICA CHIMICA ACTA, 2008, 626 (02) :180-185
[10]   Biotin-avidin mediated competitive enzyme-linked immunosorbent assay to detect residues of tetracyclines in milk [J].
Jeon, Moonsun ;
Kim, Jisun ;
Paeng, Ki-Jung ;
Park, Sung-Woo ;
Paeng, Insook Rhee .
MICROCHEMICAL JOURNAL, 2008, 88 (01) :26-31