Three year experience of electronic portal imaging device based daily QA for photon radiation beams

被引:1
|
作者
Cai, Bin [1 ]
He, Yu [1 ]
Bollinger, Douglas [1 ]
Li, Hua [1 ]
Goddu, Sreekrishna M. [1 ]
Mutic, Sasa [1 ]
Sun, Baozhou [1 ]
机构
[1] Washington Univ, Dept Radiat Oncol, St Louis, MO 63110 USA
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2019年 / 5卷 / 01期
关键词
EPID; daily QA; photon radiotherapy; QUALITY-ASSURANCE;
D O I
10.1088/2057-1976/aae419
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Anin-house developed EPID based QA strategy was deployed clinically to test daily linac performance before treatment. Beam dosimetric parameters, including output, flatness, symmetry, uniformity, TPR20/10, and MLC repeatability, as well as image quality metrics, such as high and low contrast resolutions, were recorded based on MV and kV EPID imaging analysis. Over a period of three years, data was collected and analyzed. Trend analysis with data visualization, comparisons to ionization chamber (IC) results and QA failure studies were performed to evaluate the reliability and robustness of the EPID based daily QA system. The EPID output tests over the three-year period cross-correlated with the monthly QA IC system within 1.3% and TG51 results within 1%. A consistent positive output drift was detected for all energies during that time. A faster drifting speed was observed after the installation of a new beam monitoring chamber on the machine but slowed down over time. Symmetry, flatness, and uniformity were stable and the changes were directly related to beam steering or QA baseline resetting. TPR20/10 was not sensitive to dosimetry fluctuations and a good delivery repeatability of MLC fields was observed. The image quality metrics were stable and a passing rate greater than 96% was observed. For the most recent eight month of data, a one-time QA passing rate was calculated to be 87.6%. Beam interruptions, human errors and data transfer issues were the major reasons for QA failures. The data gathered over 3 years indicates that the EPID-based process is an efficient and reliable QA solution for daily linac performance checks. The long-term trend analysis and data visualization can help physicists understand the behavior of a linac, optimize the daily QA procedure, and has the potential to predict machine failures prior to incidents.
引用
收藏
页数:9
相关论文
共 36 条
  • [1] An electronic portal image device (EPID)-based multiplatform rapid daily LINAC QA tool
    Ma, Yangguang
    Wang, Xuemin
    Mai, Rizhen
    Wang, Tao
    Pei, Yuntong
    Liu, Shuaipeng
    Guo, Yuexin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (01): : 45 - 58
  • [2] A Clinical Objective IMRT QA Method Based on Portal Dosimetry and Electronic Portal Imager Device (EPID) Measurement
    Zhang, Miao
    Qin, Songbing
    Chen, Ting
    Kim, Sung
    Jabbour, Salma
    Haffty, Bruce
    Yue, Ning J.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (02) : 145 - 150
  • [3] The linear accelerator mechanical and radiation isocentre assessment with an electronic portal imaging device (EPID)
    Liu G.
    van Doorn T.
    Bezak E.
    Australasian Physics & Engineering Sciences in Medicine, 2004, 27 (3): : 111 - 117
  • [4] Dosimetric verification of intensity modulated beams produced with dynamic multileaf collimation using an electronic portal imaging device
    Pasma, KL
    Dirkx, MLP
    Kroonwijk, M
    Visser, AG
    Heijmen, BJM
    MEDICAL PHYSICS, 1999, 26 (11) : 2373 - 2378
  • [5] A test tool for the visual verification of light and radiation fields using film or an electronic portal imaging device
    Dunscombe, P
    Humphreys, S
    Leszczynski, K
    MEDICAL PHYSICS, 1999, 26 (02) : 239 - 243
  • [6] A method for in vivo treatment verification of IMRT and VMAT based on electronic portal imaging device
    Zhang, Jun
    Li, Xiuqing
    Lu, Miaomiao
    Zhang, Qilin
    Zhang, Xile
    Yang, Ruijie
    Chan, Maria F.
    Wen, Junhai
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [7] A method for in vivo treatment verification of IMRT and VMAT based on electronic portal imaging device
    Jun Zhang
    Xiuqing Li
    Miaomiao Lu
    Qilin Zhang
    Xile Zhang
    Ruijie Yang
    Maria F. Chan
    Junhai Wen
    Radiation Oncology, 16
  • [8] Commissioning and Evaluation of an Electronic Portal Imaging Device-Based In-Vivo Dosimetry Software
    Held, Mareike
    Cheung, Joey
    Andujar, Angelica Perez
    Husson, Francois
    Morin, Olivier
    CUREUS, 2018, 10 (02):
  • [9] Two-dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device
    Vieira, SC
    Kaatee, RSJP
    Dirkx, MLP
    Heijmen, BJM
    MEDICAL PHYSICS, 2003, 30 (11) : 2981 - 2987
  • [10] Verification of milled two-dimensional photon compensating filters using an electronic portal imaging device
    Low, DA
    Li, ZF
    Klein, EE
    MEDICAL PHYSICS, 1996, 23 (06) : 929 - 938