Long-term followup for rheumatoid arthritis patients in a multicenter outcomes study of silicone metacarpophalangeal joint arthroplasty

被引:40
作者
Chung, Kevin C. [1 ]
Burns, Patricia B.
Kim, H. Myra [2 ]
Burke, Frank D. [3 ]
Wilgis, E. F. Shaw [4 ]
Fox, David A.
机构
[1] Univ Michigan Hlth Syst, Sect Plast Surg, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Ann Arbor, MI 48109 USA
[3] Pulvertaft Hand Ctr, Derby, England
[4] Curtis Natl Hand Ctr, Baltimore, MD USA
关键词
RUBBER IMPLANT ARTHROPLASTY; SILASTIC ARTHROPLASTY; CLINICAL-TRIAL; HAND SURGEONS; QUESTIONNAIRE; RHEUMATOLOGISTS; REPLACEMENT; PROSTHESIS; DISEASE; SUTTER;
D O I
10.1002/acr.21705
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective Rheumatoid arthritis (RA) often results in deformities at the metacarpophalangeal (MCP) joints. Patients with severe deformities can be treated by silicone metacarpophalangeal joint arthroplasty (SMPA). The objective of the study is to prospectively compare long-term outcomes for an SMPA surgical and a nonsurgical cohort of RA patients. Methods A total of 67 surgical and 95 nonsurgical patients with severe subluxation and/or ulnar drift of the fingers at the MCP joints were recruited from 20042008 in this multicenter prospective cohort study. Patients could elect to undergo SMPA or not. Outcomes included the Michigan Hand Outcomes Questionnaire (MHQ), Arthritis Impact Measurement Scales 2 (AIMS2), grip/pinch strength, Jebsen-Taylor Test, ulnar deviation, extensor lag, and arc of motion measurements at the MCP joints. Results There was no significant difference in the mean age, race, education, and income at baseline between the 2 groups. Surgical subjects had worse MHQ function and functional measurements at baseline. At 3 years, the mean overall MHQ score and the MHQ function, activities of daily living, aesthetics, and satisfaction scores showed significant improvement in the surgical group compared to the nonsurgical group. Ulnar deviation, extensor lag, and arc of motion in the MCP and proximal interphalangeal joints also improved significantly in the surgical group. No improvement was seen in the mean AIMS2 scores and grip/pinch strength. Complications were minimal with a fracture rate of 9.5%. Conclusion RA patients with poor baseline functioning showed long-term improvement in hand function and appearance following treatment with SMPA compared to nonsurgical controls.
引用
收藏
页码:1292 / 1300
页数:9
相关论文
共 43 条
[1]  
Alderman AK, 2003, J RHEUMATOL, V30, P1464
[2]   Effectiveness of rheumatoid hand surgery: Contrasting perceptions of hand surgeons and rheumatologists [J].
Alderman, AK ;
Chung, KC ;
Kim, HM ;
Fox, DA ;
Ubel, PA .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (01) :3-11
[3]   The rheumatoid hand: A predictable disease with unpredictable surgical practice patterns [J].
Alderman, AK ;
Chung, KC ;
Demonner, S ;
Spilson, SV ;
Hayward, RA .
ARTHRITIS & RHEUMATISM-ARTHRITIS CARE & RESEARCH, 2002, 47 (05) :537-542
[4]  
Alderman AK, 2001, SURG FORUM, VLII, P479
[5]   High implant fracture incidence with Sutter silicone metacarpophalangeal joint arthroplasty [J].
Bass, RL ;
Stern, PJ ;
Nairus, JG .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (05) :813-818
[6]   REVIEW AND ANALYSIS OF SILICONE-RUBBER METACARPOPHALANGEAL IMPLANTS [J].
BECKENBAUGH, RD ;
DOBYNS, JH ;
LINSCHEID, RL ;
BRYAN, RS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (04) :483-486
[7]   SILICONE-RUBBER IMPLANT ARTHROPLASTY OF THE METACARPOPHALANGEAL JOINTS FOR RHEUMATOID-ARTHRITIS [J].
BIEBER, EJ ;
WEILAND, AJ ;
VOLENECDOWLING, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (02) :206-209
[8]   METACARPOPHALANGEAL JOINT IMPLANT ARTHROPLASTY WITH A SILASTIC SPACER [J].
BLAIR, WF ;
SHURR, DG ;
BUCKWALTER, JA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (03) :365-370
[9]  
Bogoch ER, 2002, J RHEUMATOL, V29, P2477
[10]   Reliability and validity testing of the Michigan Hand Outcomes Questionnaire [J].
Chung, KC ;
Pillsbury, MS ;
Walters, MR ;
Hayward, RA .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (04) :575-587