Comfort under personally controlled air movement in warm and humid environments

被引:172
作者
Zhai, Yongchao [1 ,2 ]
Zhang, Hui [2 ]
Zhang, Yufeng [1 ]
Pasut, Wilmer [2 ]
Arens, Edward [2 ]
Meng, Qinglin [1 ]
机构
[1] S China Univ Technol, Dept Architecture, State Key Lab Subtrop Bldg Sci, Guangzhou 510640, Guangdong, Peoples R China
[2] Univ Calif Berkeley, Ctr Built Environm, Berkeley, CA 94720 USA
基金
中国国家自然科学基金;
关键词
Thermal comfort; Perceived air quality; Warm-humid; Air movement; Personal control; Low energy; THERMAL COMFORT; TEMPERATURE; PERFORMANCE; THAILAND; TROPICS;
D O I
10.1016/j.buildenv.2013.03.022
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study examined the effects of personally controlled air movement on human thermal comfort and perceived air quality (PAQ) in warm-humid environments. At temperatures 26, 28, and 30 degrees C, and relative humidity (RH) 60% and 80%, sixteen human subjects were exposed to personally controlled air movement provided by floor fans in an environmental chamber. The subjects reported their thermal sensation, thermal comfort, and PAQ during the tests. Two breaks periods with elevated metabolic levels were used to simulate normal office activities. Results show that with personally controlled air movement, thermal comfort could be maintained up to 30 degrees C and 60% RH, and acceptable PAQ could be maintained up to 30 degrees C 80% RH, without discomfort from humidity, air movement or eye-dryness. Thermal comfort and PAQ were resumed within 5 min after the breaks. The 80% acceptable limit implicit in comfort standards could be extended to 30 degrees C and 60% RH. The average energy consumed by the fans for maintaining comfort was lower than 10 W per person, making air movement a very energy-efficient way to deliver comfort in warm-humid environments. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:109 / 117
页数:9
相关论文
共 35 条
[1]  
[Anonymous], 6212010 ANSIASHRAEIE
[2]  
[Anonymous], 552010 ANSIASHRAEIES
[3]   A study of occupant cooling by personally controlled air movement [J].
Arens, E ;
Xu, TF ;
Miura, K ;
Hui, Z ;
Fountain, M ;
Bauman, F .
ENERGY AND BUILDINGS, 1998, 27 (01) :45-59
[4]  
Arens E, 2008, P IND AIR 08 2008 CO
[5]  
Arens E, 2011, P IND AIR 11 2011 AU
[6]  
Arens E, 2009, ASHRAE J, V51, P18
[7]   A TALE OF 2 POPULATIONS - THERMAL COMFORT IN AIR-CONDITIONED AND NATURALLY VENTILATED OFFICES IN THAILAND [J].
BUSCH, JF .
ENERGY AND BUILDINGS, 1992, 18 (3-4) :235-249
[8]   Air movement acceptability limits and thermal comfort in Brazil's hot humid climate zone [J].
Candido, C. ;
de Dear, R. J. ;
Lamberts, R. ;
Bittencourt, L. .
BUILDING AND ENVIRONMENT, 2010, 45 (01) :222-229
[9]   Thermal sensation of Hong Kong people with increased air speed, temperature and humidity in air-conditioned environment [J].
Chow, T. T. ;
Fong, K. F. ;
Givoni, B. ;
Lin, Zhang ;
Chan, A. L. S. .
BUILDING AND ENVIRONMENT, 2010, 45 (10) :2177-2183
[10]   Influence of dynamic environment with different airflows on human performance [J].
Cui, Weilin ;
Cao, Guoguang ;
Ouyang, Qin ;
Zhu, Yingxin .
BUILDING AND ENVIRONMENT, 2013, 62 :124-132