Precision of Ci-navigated extension and flexion gap balancing in total knee arthroplasty and analysis of potential predictive variables

被引:12
作者
Fickert, S. [1 ]
Jawhar, A. [1 ]
Sunil, P. [2 ]
Scharf, H. -P [1 ]
机构
[1] Univ Med Ctr Mannheim, Orthoped & Trauma Surg Ctr, D-68167 Mannheim, Germany
[2] Apollo Hosp, Hyderabad, Andhra Pradesh, India
关键词
Total knee arthroplasty; Computer-assisted navigation; Ligament balancing; Gap balancing; Flexion and extension gap; Leg axis; COMPUTER-ASSISTED NAVIGATION; CRUCIATE LIGAMENT; CUTTING ERRORS; REPLACEMENT; ALIGNMENT; IMPLANTATION; ACCURACY; RELEASE; PROSTHESES; SURGERY;
D O I
10.1007/s00402-011-1419-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction The aim of this study was to evaluate the accuracy of final limb alignment and flexion-extension and medial-lateral gap balancing in computer navigated total knee arthroplasty and to analyze various possible predictive variables that may affect the gaps in computer navigated knee arthroplasty. Materials and methods The DePuy Ci system, a nonimage-based passive optical computer navigation system, was used in 225 patients with knee osteoarthritis to assist for the total knee arthroplasty. From the raw data the Ci-verified pre- and postoperative leg axis in extension, angle of tibia and femur resection, the flexion and extension angle, the medial and lateral extension and flexion gaps were extracted; and differences in gaps were calculated and subjected to statistical analysis. Leg alignment and implant position were determined only by the navigation system. Preoperative variables were evaluated for their impact on the final flexion/extension and medial/lateral gaps achieved. Results Though the preoperative femoro-tibial coronal alignment had a large variance, postoperatively 98.22% of the knee was found to be between -3 degrees and +3 degrees in the coronal limb alignment axis. The Ci-verified femoral and tibial cuts in the coronal plane showed a good accuracy. The sagittal alignment of the femoral cut ranged from 8.20 degrees flexion to 3.20 degrees of extension. Rectangular extension and flexion gaps were achieved with <= 3 mm of difference in gaps on medial and lateral sides in 98 and 93% of knees, respectively. Difference between extension and flexion gaps on the medial side was <= 3 mm in 83% and on the lateral side in 84% of the knees. Of all the possible predictive variables analyzed, Pearson correlation and multiple regression analysis showed significant correlation only between the medial-lateral gap difference in extension and the Ci-verified femoral cut, tibial cut and limb axis, all in the coronal plane. Conclusion Computer-assisted navigated total knee replacement allows for accurate gap balancing that is not dependent on the various pre- and intraoperative factors mentioned, including age, sex, Range of motion preoperative deformity and grade of osteoarthritis. The Ci-calculated and verified tibial, and femoral cuts are the only possible factors affecting the extension gap.
引用
收藏
页码:565 / 574
页数:10
相关论文
共 39 条
[1]   Computer assisted navigation in total knee arthroplasty - Comparison with conventional methods [J].
Anderson, KC ;
Buehler, KC ;
Markel, DC .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :132-138
[2]  
Arima J, 1998, CLIN ORTHOP RELAT R, P194
[3]   Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[4]   Tibial component failure mechanisms in total knee arthroplasty [J].
Berend, ME ;
Ritter, MA ;
Meding, JB ;
Faris, PM ;
Keating, EM ;
Redelman, R ;
Faris, GW ;
Davis, KE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) :26-34
[5]   The accuracy of bone resections made during computer navigated total knee replacement. Do we resect what the computer plans we resect? [J].
Biant, Leela C. ;
Yeoh, Kwan ;
Walker, Peter M. ;
Bruce, Warwick J. M. ;
Walsh, William R. .
KNEE, 2008, 15 (03) :238-241
[6]   Computer navigation versus standard instrumentation for TKA - A single-surgeon experience [J].
Bolognesi, M ;
Hofmann, A .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) :162-169
[7]   Gap balancing in total knee arthroplasty [J].
Bottros, John ;
Gad, Bishoy ;
Krebs, Viktor ;
Barsoum, Wael K. .
JOURNAL OF ARTHROPLASTY, 2006, 21 (04) :11-15
[8]   Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial [J].
Chauhan, SK ;
Scott, RG ;
Breidahl, W ;
Beaver, RJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03) :372-377
[9]  
Daubresse Francois, 2005, Acta Orthop Belg, V71, P710
[10]   Leg axis after computer-navigated total knee arthroplasty - A prospective randomized trial comparing computer-navigated and manual implantation [J].
Decking, R ;
Markmann, Y ;
Fuchs, J ;
Puhl, W ;
Scharf, HP .
JOURNAL OF ARTHROPLASTY, 2005, 20 (03) :282-288