MRI issues for ballistic objects: information obtained at 1.5-, 3-and 7-Tesla

被引:56
作者
Dedini, Russell D. [1 ]
Karacozoff, Alexandra M. [2 ]
Shellock, Frank G. [3 ,4 ]
Xu, Duan [5 ]
McClellan, R. Trigg [1 ]
Pekmezci, Murat [1 ]
机构
[1] Univ Calif San Francisco, San Francisco Gen Hosp, Dept Orthopaed Surg, Orthopaed Trauma Inst, San Francisco, CA 94110 USA
[2] Loyola Marymount Univ, Los Angeles, CA 90045 USA
[3] Univ So Calif, Keck Sch Med, Los Angeles, CA 90045 USA
[4] Inst Magnet Resonance Safety Educ & Res, Los Angeles, CA 90045 USA
[5] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94158 USA
关键词
Magnetic resonance imaging; safety; Heating; MRI; Artifacts; Bullets; Ballistics; MAGNETIC-FIELD INTERACTIONS; IN-VITRO EVALUATION; BIOMEDICAL IMPLANTS; ARTIFACTS; DEVICES; FRAGMENTS; SAFETY;
D O I
10.1016/j.spinee.2013.02.068
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Few studies exist for magnetic resonance imaging (MRI) issues and ballistics, and there are no studies addressing movement, heating, and artifacts associated with ballistics at 3-tesla (T). Movement because of magnetic field interactions and radiofrequency (RF)-induced heating of retained bullets may injure nearby critical structures. Artifacts may also interfere with the diagnostic use of MRI. PURPOSE: To investigate these potential hazards of MRI on a sample of bullets and shotgun pellets. STUDY DESIGN: Laboratory investigation, ex vivo. METHODS: Thirty-two different bullets and seven different shotgun pellets, commonly encountered in criminal trauma, were assessed relative to 1.5-, 3-, and 7-T magnetic resonance systems. Magnetic field interactions, including translational attraction and torque, were measured. A representative sample of five bullets were then tested for magnetic field interactions, RF-induced heating, and the generation of artifacts at 3-T. RESULTS: At all static magnetic field strengths, non-steel-containing bullets and pellets exhibited no movement, whereas one steel core bullet and two steel pellets exhibited movement in excess of what might be considered safe for patients in MRI at 1.5-, 3- and 7-Tesla. At 3-T, the maximum temperature increase of five bullets tested was 1.7 degrees C versus background heating of 1.5 degrees C. Of five bullets tested for artifacts, those without a steel core exhibited small signal voids, whereas a single steel core bullet exhibited a very large signal void. CONCLUSIONS: Ballistics made of lead with copper or alloy jackets appear to be safe with respect to MRI-related movement at 1.5-, 3-, and 7-T static magnetic fields, whereas ballistics containing steel may pose a danger if near critical body structures because of strong magnetic field interactions. Temperature increases of selected ballistics during 3-T MRI was not clinically significant, even for the ferromagnetic projectiles. Finally, ballistics containing steel generated larger artifacts when compared with ballistics made of lead with copper and alloy jackets and may impair the diagnostic use of MRI. (c) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:815 / 822
页数:8
相关论文
共 27 条
[1]  
American Society for Testing and Materials (ASTM) International, 2001, ANN BOOK ASTM STAND, P1576
[2]  
[Anonymous], 2011, F218211 ASTM
[3]  
[Anonymous], REFERENCE MANUAL MAG
[4]   Neurostimulation systems: Assessment of magnetic field interactions associated with 1.5-and 3-Tesla MR systems [J].
Baker, KB ;
Nyenhuis, JA ;
Hrdlicka, G ;
Rezai, AR ;
Tkach, JA ;
Shellock, FG .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (01) :72-77
[5]   Is magnetic resonance imaging safe for patients with retained metal fragments from combat and terrorist attacks? [J].
Eshed, Iris ;
Kushnir, Tamar ;
Shabshin, Noga ;
Konen, Eli .
ACTA RADIOLOGICA, 2010, 51 (02) :170-+
[6]   Metal-Induced Artifacts in MRI [J].
Hargreaves, Brian A. ;
Worters, Pauline W. ;
Pauly, Kim Butts ;
Pauly, John M. ;
Koch, Kevin M. ;
Gold, Garry E. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) :547-555
[7]  
Houdas Y., 1982, PRINCIPLES HEAT TRAN
[8]  
JOURDAN P, 1989, Journal de Radiologie (Paris), V70, P685
[9]   MR heating tests of MR critical implants [J].
Kainz, Wolfgang .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (03) :450-451
[10]  
Karacozoff Alexandra M, 2013, Mil Med, V178, pe380, DOI 10.7205/MILMED-D-12-00374