An assessment of a modern touch-screen tablet computer with reference to core physical characteristics necessary for clinical vision testing

被引:36
作者
Aslam, Tariq M. [1 ,2 ]
Murray, Ian J. [2 ,3 ,4 ]
Lai, Michael Y. T. [5 ]
Linton, Emma [1 ]
Tahir, Humza J. [3 ,4 ]
Parry, Neil R. A. [2 ,3 ,4 ]
机构
[1] Univ Manchester, Fac Med & Human Sci, Manchester M13 9PL, Lancs, England
[2] Cent Manchester Univ Hosp NHS Fdn Trust, Manchester Royal Eye Hosp, Manchester Acad Hlth Sci Ctr, Manchester M13 9WL, Lancs, England
[3] Univ Manchester, Hlth Sci Res Ctr, Manchester M13 9NT, Lancs, England
[4] Univ Manchester, Vis Sci Ctr, Manchester M13 9NT, Lancs, England
[5] Birmingham & Midland Eye Ctr, Birmingham B18 7QH, W Midlands, England
关键词
visual function; iPad; tablet computer; vision testing;
D O I
10.1098/rsif.2013.0239
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
There are a multitude of applications using modern tablet computers for vision testing that are accessible to ophthalmology patients. While these may be of potential future benefit, they are often unsupported by scientific assessment. This report investigates the pertinent physical characteristics behind one of the most common highest specification tablet computers with regard to its capacity for vision testing. We demonstrate through plotting of a gamma curve that it is feasible to produce a precise programmable range of central luminance levels on the device, even with varying background luminance levels. It may not be possible to display very low levels of contrast, but carefully using the gamma curve information allows a reasonable range of contrast sensitivity to be tested. When the screen is first powered on, it may require up to 15 min for the luminance values to stabilize. Finally, luminance of objects varies towards the edge of the screen and when viewed at an angle. However, the resulting effective contrast of objects is less variable. Details of our assessments are important to developers, users and prescribers of tablet clinical vision tests. Without awareness of such findings, these tests may never reach satisfactory levels of clinical validity and reliability.
引用
收藏
页数:4
相关论文
共 5 条
[1]   The performance of general-purpose colour CRT monitors in PACS environment [J].
Kondoh, H ;
Hatazawa, K ;
Kozuka, T .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2001, 66 (01) :63-68
[2]   Normal values for the Pelli-Robson contrast sensitivity test [J].
Mäntyjärvi, M ;
Laitinen, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (02) :261-266
[3]   How big is the burden of visual loss caused by age related macular degeneration in the United Kingdom? [J].
Owen, CG ;
Fletcher, AE ;
Donoghue, M ;
Rudnicka, AR .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (03) :312-317
[4]  
Samei E., 2002, QUALITY ASSURANCE QU, P71
[5]   Visual Impairment and quality of life in the Older European Population, the EUREYE study [J].
Seland, Johan H. ;
Vingerling, Johannes R. ;
Augood, Cristina A. ;
Bentham, Graham ;
Chakravarthy, Usha ;
deJong, Paulus T. V. M. ;
Rahu, Mati ;
Soubrane, Gisele ;
Tomazzoli, Laura ;
Topouzis, Fotis ;
Fletcher, Astrid E. .
ACTA OPHTHALMOLOGICA, 2011, 89 (07) :608-613