Application of fluorescent nuclear track detectors for cellular dosimetry

被引:15
|
作者
Rahmanian, S. [1 ,2 ]
Niklas, M. [2 ,3 ]
Abdollahi, A. [2 ,3 ,4 ]
Jaekel, O. [1 ,2 ,4 ]
Greilich, S. [1 ,2 ]
机构
[1] German Canc Ctr DKFZ, Div Med Phys Radiat Oncol, Heidelberg, Germany
[2] Heidelberger Inst Radioonkol HIRO, Heidelberg, Germany
[3] German Canc Ctr DKFZ, Div Translat Radiat Oncol, Heidelberg, Germany
[4] Heidelberg Ion Beam Therapy Ctr HIT, Heidelberg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 07期
关键词
fluorescent nuclear track detectors; ion beam radiotherapy; cellular energy deposition; microdosimetry; linear energy transfer; radiobiological modeling; microscopic dose fluctuation; MICRODOSIMETRIC-KINETIC MODEL; CARBON ION THERAPY; RADIATION-THERAPY; MAMMALIAN-CELLS; BEAM THERAPY; HEAVY-IONS; TECHNOLOGY; PROTON; RBE; SPECTROSCOPY;
D O I
10.1088/1361-6560/aa56b4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ion beams radiotherapy with charged particles show greater relative biological effectiveness (RBE) compared to conventional photon therapy. This enhanced RBE is due to a localized energy deposition pattern, which is subject to large fluctuations on cellular scales. Fluorescent nuclear track detectors (FNTDs) based on Al2O3:C, Mg crystals coated with cells (Cell-Fit-HD) can provide information on individual cellular energy deposition. In this study we provide a theoretical framework to obtain the distribution of microscopic energy deposition and ionization density in cells exposed to ion beams and identifies contributions of five different sources of variations to the overall energy fluctuation at different depths of a biologically optimized spread-out Bragg peak. We show that fluctuation in the individual energy loss of the particles is the major source of variability while the fluctuation in particle hits plays a minor role. With the Cell-Fit-HD system the uncertainty arising from four of these sources, namely the nucleus area, the number of nuclear hits, the particle linear energy transfer and the chord length can be reduced and only energy loss straggling remains fundamentally unknown. The ability to quantify these factors results in a reduction of the uncertainty in cellular energy deposition from 24-55% down to only 7-12%. We have also shown current experimental results with FNTDs which show promising results, but need further improvements to reach the ideals predicted in this study.
引用
收藏
页码:2719 / 2740
页数:22
相关论文
共 50 条
  • [31] Study on the reusability of fluorescent nuclear track detectors using optical bleaching
    Muneem, Abdul
    Yoshida, Junya
    Ekawa, Hiroyuki
    Hino, Masahiro
    Hirota, Katsuya
    Ichikawa, Go
    Kasagi, Ayumi
    Kitaguchi, Masaaki
    Kodaira, Satoshi
    Mishima, Kenji
    Nabi, Jameel-Un
    Nakagawa, Manami
    Sakashita, Michio
    Saito, Norihito
    Saito, Takehiko R.
    Wada, Satoshi
    Yasuda, Nakahiro
    RADIATION MEASUREMENTS, 2022, 158
  • [32] Nanoscale measurements of proton tracks using fluorescent nuclear track detectors
    Sawakuchi, Gabriel O.
    Ferreira, Felisberto A.
    McFadden, Conor H.
    Hallacy, Timothy M.
    Granville, Dal A.
    Sahoo, Narayan
    Akselrod, Mark S.
    MEDICAL PHYSICS, 2016, 43 (05) : 2485 - 2490
  • [33] Fluorescent nuclear track detectors - Review of past, present and future of the technology
    Akselrod, Mark
    Kouwenberg, Jasper
    RADIATION MEASUREMENTS, 2018, 117 : 35 - 51
  • [34] THE APPLICATION OF SOLID-STATE NUCLEAR TRACK DETECTORS IN NUCLEAR SAFEGUARDS
    BOCK, H
    MULLER, H
    VANA, N
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1981, 5 (04): : 369 - 369
  • [35] Single track coincidence measurements of fluorescent and plastic nuclear track detectors in therapeutic carbon beams
    Osinga, J. -M.
    Ambrozova, I.
    Brabcova, K. Pachnerova
    Akselrod, M. S.
    Jaekel, O.
    Davidkova, M.
    Greilich, S.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [36] Carbon ion dosimetry on a fluorescent nuclear track detector using widefield microscopy
    Walsh, Dietrich W. M.
    Liew, Hans
    Schlegel, Julian
    Mairani, Andrea
    Abdollahi, Amir
    Niklas, Martin
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (21):
  • [37] AUTOMATIC NEUTRON DOSIMETRY SYSTEM BASED ON FLUORESCENT NUCLEAR TRACK DETECTOR TECHNOLOGY
    Akselrod, M. S.
    Fomenko, V. V.
    Bartz, J. A.
    Haslett, T. L.
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 86 - 91
  • [38] Radon dosimetry using Solid State Nuclear Track Detectors in different environments: a review
    Takahashi, Laura Cardoso
    Santos, Talita de Oliveira
    Marques Pinheiro, Rose Mary
    Passos, Ricardo Gomes
    Rocha, Zildete
    APPLIED RADIATION AND ISOTOPES, 2022, 186
  • [39] Improvement of response of CR-39 nuclear track detectors in fast neutron dosimetry
    Brede, HJ
    Gisbertz, A
    Köhler, I
    Pitt, E
    Scharmann, A
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 113 - 116
  • [40] NEUTRON DOSIMETRY WITH NUCLEAR TRACK DETECTORS APPLIED TO IN-VIVO NEUTRON ACTIVATION ANALYSIS
    AGARD, ET
    JERVIS, RE
    MCNEILL, KG
    HEALTH PHYSICS, 1970, 19 (02): : 330 - +