Application of fluorescent nuclear track detectors for cellular dosimetry

被引:15
|
作者
Rahmanian, S. [1 ,2 ]
Niklas, M. [2 ,3 ]
Abdollahi, A. [2 ,3 ,4 ]
Jaekel, O. [1 ,2 ,4 ]
Greilich, S. [1 ,2 ]
机构
[1] German Canc Ctr DKFZ, Div Med Phys Radiat Oncol, Heidelberg, Germany
[2] Heidelberger Inst Radioonkol HIRO, Heidelberg, Germany
[3] German Canc Ctr DKFZ, Div Translat Radiat Oncol, Heidelberg, Germany
[4] Heidelberg Ion Beam Therapy Ctr HIT, Heidelberg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 07期
关键词
fluorescent nuclear track detectors; ion beam radiotherapy; cellular energy deposition; microdosimetry; linear energy transfer; radiobiological modeling; microscopic dose fluctuation; MICRODOSIMETRIC-KINETIC MODEL; CARBON ION THERAPY; RADIATION-THERAPY; MAMMALIAN-CELLS; BEAM THERAPY; HEAVY-IONS; TECHNOLOGY; PROTON; RBE; SPECTROSCOPY;
D O I
10.1088/1361-6560/aa56b4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ion beams radiotherapy with charged particles show greater relative biological effectiveness (RBE) compared to conventional photon therapy. This enhanced RBE is due to a localized energy deposition pattern, which is subject to large fluctuations on cellular scales. Fluorescent nuclear track detectors (FNTDs) based on Al2O3:C, Mg crystals coated with cells (Cell-Fit-HD) can provide information on individual cellular energy deposition. In this study we provide a theoretical framework to obtain the distribution of microscopic energy deposition and ionization density in cells exposed to ion beams and identifies contributions of five different sources of variations to the overall energy fluctuation at different depths of a biologically optimized spread-out Bragg peak. We show that fluctuation in the individual energy loss of the particles is the major source of variability while the fluctuation in particle hits plays a minor role. With the Cell-Fit-HD system the uncertainty arising from four of these sources, namely the nucleus area, the number of nuclear hits, the particle linear energy transfer and the chord length can be reduced and only energy loss straggling remains fundamentally unknown. The ability to quantify these factors results in a reduction of the uncertainty in cellular energy deposition from 24-55% down to only 7-12%. We have also shown current experimental results with FNTDs which show promising results, but need further improvements to reach the ideals predicted in this study.
引用
收藏
页码:2719 / 2740
页数:22
相关论文
共 50 条
  • [1] Alpha radiation dosimetry using Fluorescent Nuclear Track Detectors
    Kouwenberg, J. J. M.
    de Pooter, J. A.
    Wolterbeek, H. T.
    Denkova, A. G.
    Bos, A. J. J.
    RADIATION MEASUREMENTS, 2018, 113 : 25 - 32
  • [2] Properties of novel fluorescent nuclear track detectors for use in passive neutron dosimetry
    Sykora, G. J.
    Salasky, M.
    Akselrod, M. S.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 1017 - 1023
  • [3] RADON DOSIMETRY USING PLASTIC NUCLEAR TRACK DETECTORS
    FRANK, AL
    BENTON, EV
    NUCLEAR TRACK DETECTION, 1977, 1 (3-4): : 149 - 179
  • [4] Converter thickness optimisation using Monte Carlo simulations of Fluorescent Nuclear Track Detectors for neutron dosimetry
    Schmidt, Stefan
    Stabilini, Alberto
    Thai, Long-Yang J.
    Yukihara, Eduardo G.
    Jaekel, Oliver
    Vedelago, Jose
    RADIATION MEASUREMENTS, 2024, 173
  • [5] Nuclear track detectors in cellular radiation biology
    Durante, M
    Grossi, GF
    Pugliese, M
    Gialanella, G
    RADIATION MEASUREMENTS, 1996, 26 (02) : 179 - 186
  • [6] Nuclear track detectors in cellular radiation biology
    Universita `Federico II', Napoli, Italy
    Radiat Meas, 2 (179-186):
  • [7] PLASTICS AS NUCLEAR TRACK DETECTORS FOR THERMAL-NEUTRON DOSIMETRY
    FARID, SM
    SHARMA, AP
    DURRANI, SA
    PRAMANA, 1983, 20 (06) : 559 - 567
  • [8] Neutron dosimetry device using PADC nuclear track detectors
    Saint Martin, Gisela
    Lopez, F.
    Bernaola, O. A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 287 (02) : 635 - 638
  • [9] APPLICATIONS OF NUCLEAR TRACK DETECTORS IN SPACE RADIATION DOSIMETRY.
    Benton, E.V.
    Richmond, Robert G.
    Nuclear tracks, 1985, 12 (1-6): : 505 - 508
  • [10] APPLICATIONS OF NUCLEAR TRACK DETECTORS IN SPACE RADIATION-DOSIMETRY