CALIBRATION OF THE HIGH AND LOW RESOLUTION GAMMA-RAY SPECTROMETERS

被引:0
|
作者
Luca, Aurelian [1 ]
Neacsu, Beatris [1 ]
Antohe, Andrei [1 ]
Sahagia, Maria [1 ]
机构
[1] IFIN HH Bucharest, Horia Hulubei Natl Inst Phys & Nucl Engn, RO-077125 Bucharest, Romania
关键词
Gamma-ray spectrometry; calibration; activity measurements;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Many laboratories accredited according to the requirements of the standard EN ISO/IEC 17025:2005 "General requirements for the competence of testing and calibration laboratories" are implied in the radioactive content measurement of samples collected from the environment, food chain or industrial products. The most used method is the gamma-ray spectrometry measurement, using high resolution HPGe and low resolution NaI(Tl) detectors. In order to improve its sensitivity, many technical and methodological aspects are important: careful choice of detector material and shielding, samples matrix, measurement of high volume samples in close to detector geometries. The results are strongly influenced by the geometry, sample volume and content, and true coincidence summing effects (for cascade gamma-ray emitters), as demonstrated during many proficiency tests. The Radionuclide Metrology Laboratory from IFIN-HH, Primary Activity Standard Laboratory, assures the continuity of the whole metrological traceability chain of activity measurement and is accredited by the national accreditation body RENAR as a Calibration and Testing Laboratory, offering products and services for clients. Within the frame of its QMS, RML elaborated two working procedures for the calibration of the gamma-ray spectrometers and the low level radioactive samples activity measurement. The calibration procedures are described, emphasizing the corrections applicable by the measurement laboratories.
引用
收藏
页码:968 / 976
页数:9
相关论文
共 50 条
  • [21] An investigation of the repeatability of calibration factors in gamma-ray spectrometry of geological materials
    Mustapha, AO
    Patel, JP
    Rathore, IVS
    Hashim, NO
    Otwoma, D
    APPLIED RADIATION AND ISOTOPES, 2004, 60 (01) : 79 - 82
  • [22] Calibration of HPGe gamma-ray detectors for measurement of radioactive noble gas sources
    Pibida, L.
    Nafee, S. S.
    Unterweger, M.
    Hammond, M. M.
    Karam, L.
    Abbas, M. I.
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (02) : 225 - 233
  • [23] Semi-automated structural analysis of high resolution magnetic and gamma-ray spectrometry airborne surveys
    Debeglia, N
    Martelet, G
    Perrin, J
    Truffert, C
    Ledru, P
    Tourlière, B
    JOURNAL OF APPLIED GEOPHYSICS, 2006, 58 (01) : 13 - 28
  • [24] Near-field high-resolution coded aperture gamma-ray imaging with separable masks
    Sun, Shifeng
    Liu, Yang
    Ouyang, Xiaoping
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 951 (951):
  • [25] Determination of primordial radionuclide concentrations in UAE groundwater using high-resolution gamma-ray spectrometry
    Rahaf Ajaj
    Nasser Shubyar
    Yazeed Alashban
    Samar El-Sayed
    Tamar Salah
    Mohammed A. Salem Al Yafei
    Journal of Radioanalytical and Nuclear Chemistry, 2021, 330 : 923 - 928
  • [26] Background radiation reduction for a high-resolution gamma-ray spectrometer used for environmental radioactivity measurements
    Radulescu, I.
    Blebea-Apostu, A. M.
    Margineanu, R. M.
    Mocanu, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 715 : 112 - 118
  • [27] Determination of primordial radionuclide concentrations in UAE groundwater using high-resolution gamma-ray spectrometry
    Ajaj, Rahaf
    Shubyar, Nasser
    Alashban, Yazeed
    El-Sayed, Samar
    Salah, Tamar
    Al Yafei, Mohammed A. Salem
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2021, 330 (03) : 923 - 928
  • [28] Low background germanium planar detector for gamma-ray spectrometry
    Loaiza, P.
    Chassaing, C.
    Hubert, Ph
    Nachab, A.
    Perrot, F.
    Reyss, J-L
    Warot, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 634 (01): : 64 - 70
  • [29] Ground-based calibration and characterization of the Fermi gamma-ray burst monitor detectors
    E. Bissaldi
    A. von Kienlin
    G. Lichti
    H. Steinle
    P. N. Bhat
    M. S. Briggs
    G. J. Fishman
    A. S. Hoover
    R. M. Kippen
    M. Krumrey
    M. Gerlach
    V. Connaughton
    R. Diehl
    J. Greiner
    A. J. van der Horst
    C. Kouveliotou
    S. McBreen
    C. A. Meegan
    W. S. Paciesas
    R. D. Preece
    C. A. Wilson-Hodge
    Experimental Astronomy, 2009, 24 : 47 - 88
  • [30] Ground-based calibration and characterization of the Fermi gamma-ray burst monitor detectors
    Bissaldi, E.
    von Kienlin, A.
    Lichti, G.
    Steinle, H.
    Bhat, P. N.
    Briggs, M. S.
    Fishman, G. J.
    Hoover, A. S.
    Kippen, R. M.
    Krumrey, M.
    Gerlach, M.
    Connaughton, V.
    Diehl, R.
    Greiner, J.
    van der Horst, A. J.
    Kouveliotou, C.
    McBreen, S.
    Meegan, C. A.
    Paciesas, W. S.
    Preece, R. D.
    Wilson-Hodge, C. A.
    EXPERIMENTAL ASTRONOMY, 2009, 24 (1-3) : 47 - 88