CALIBRATION OF THE HIGH AND LOW RESOLUTION GAMMA-RAY SPECTROMETERS

被引:0
|
作者
Luca, Aurelian [1 ]
Neacsu, Beatris [1 ]
Antohe, Andrei [1 ]
Sahagia, Maria [1 ]
机构
[1] IFIN HH Bucharest, Horia Hulubei Natl Inst Phys & Nucl Engn, RO-077125 Bucharest, Romania
关键词
Gamma-ray spectrometry; calibration; activity measurements;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Many laboratories accredited according to the requirements of the standard EN ISO/IEC 17025:2005 "General requirements for the competence of testing and calibration laboratories" are implied in the radioactive content measurement of samples collected from the environment, food chain or industrial products. The most used method is the gamma-ray spectrometry measurement, using high resolution HPGe and low resolution NaI(Tl) detectors. In order to improve its sensitivity, many technical and methodological aspects are important: careful choice of detector material and shielding, samples matrix, measurement of high volume samples in close to detector geometries. The results are strongly influenced by the geometry, sample volume and content, and true coincidence summing effects (for cascade gamma-ray emitters), as demonstrated during many proficiency tests. The Radionuclide Metrology Laboratory from IFIN-HH, Primary Activity Standard Laboratory, assures the continuity of the whole metrological traceability chain of activity measurement and is accredited by the national accreditation body RENAR as a Calibration and Testing Laboratory, offering products and services for clients. Within the frame of its QMS, RML elaborated two working procedures for the calibration of the gamma-ray spectrometers and the low level radioactive samples activity measurement. The calibration procedures are described, emphasizing the corrections applicable by the measurement laboratories.
引用
收藏
页码:968 / 976
页数:9
相关论文
共 50 条
  • [1] Assessment of the detection efficiency calibration of high-resolution gamma-ray spectrometers by EGSnrc and MCNP6.2 Monte Carlo codes
    Sayin, Sefa
    Seferinoglu, Meryem
    Yeltepe, Emin
    Cetin, Berkay
    Lule, Senem Senturk
    RADIATION PHYSICS AND CHEMISTRY, 2023, 203
  • [2] Calibration of the well-type germanium gamma-ray detector employing two gamma-ray spectra
    Blaauw, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 419 (01): : 146 - 153
  • [3] PANGU: A High Resolution Gamma-ray Space Telescope
    Wu, Xin
    Su, Meng
    Bravar, Alessandro
    Chang, Jin
    Fan, Yizhong
    Pohl, Martin
    Walter, Roland
    SPACE TELESCOPES AND INSTRUMENTATION 2014: ULTRAVIOLET TO GAMMA RAY, 2014, 9144
  • [4] A method for the comparison of performance of gamma-ray spectrometry calibration cocktails
    Legarda, F
    Los Arcos, JM
    Herranz, M
    APPLIED RADIATION AND ISOTOPES, 2004, 60 (2-4) : 547 - 551
  • [5] High resolution gamma-ray spectrometry for routine measurements of environmental samples
    Eleftheriou, G.
    Tsabaris, C.
    Androulakaki, E. G.
    Pappa, F. K.
    Patiris, D. L.
    APPLIED RADIATION AND ISOTOPES, 2024, 206
  • [6] Influence of 210Pb on the continuous background of gamma-ray spectrometers
    Korun, M.
    Vodenik, B.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (05) : 762 - 764
  • [7] Comparison of gamma-ray coincidence and low-background gamma-ray singles spectrometry
    Konki, J.
    Greenlees, P. T.
    Jakobsson, U.
    Jones, P.
    Julin, R.
    Juutinen, S.
    Ketelhut, S.
    Hauschild, K.
    Kontro, R.
    Leppanen, A. -P.
    Lopez-Martens, A.
    Mattila, A.
    Nieminen, P.
    Nyman, M.
    Perajarvi, K.
    Peura, P.
    Rahkila, P.
    Ruotsalainen, P.
    Saren, J.
    Scholey, C.
    Sorri, J.
    Toivonen, H.
    Turunen, J.
    Uusitalo, J.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (02) : 392 - 396
  • [8] Carborne gamma-ray spectrometry. Calibration and applications
    Aage, H. K.
    Korsbech, U.
    Bargholz, K.
    Hovgaard, J.
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (08) : 948 - 956
  • [9] A comparison of simple algorithms for gamma-ray spectrometers in radioactive source search applications
    Jarman, Kenneth D.
    Runkle, Robert C.
    Anderson, Kevin K.
    Pfund, David M.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (03) : 362 - 371
  • [10] On-ground calibration of low gain response for Gamma-Ray Detectors onboard the GECAM satellite
    Chaoyang Li
    Wenxi Peng
    Yaqing Liu
    Xingzhu Cui
    Zhenghua An
    Xinqiao Li
    Shaolin Xiong
    Dali Zhang
    Ke Gong
    Min Gao
    Dongya Guo
    Xiaohua Liang
    Xiaojing Liu
    Rui Qiao
    Xilei Sun
    Jinzhou Wang
    Xiangyang Wen
    Yanbing Xu
    Sheng Yang
    Fan Zhang
    Xiaoyun Zhao
    Juncheng Liang
    Haoran Liu