Gas alternatives to carbon dioxide for euthanasia: A piglet perspective

被引:17
作者
Rault, J. -L. [1 ]
McMunn, K. A. [2 ]
Marchant-Forde, J. N. [2 ]
Lay, D. C., Jr. [2 ]
机构
[1] Purdue Univ, Dept Anim Sci, W Lafayette, IN 47907 USA
[2] USDA ARS, Livestock Behav Res Unit, W Lafayette, IN 47907 USA
关键词
anesthesia; carbon dioxide; euthanasia; gas; nitrous oxide; piglet; WELFARE IMPLICATIONS; HEART-RATE; PIGS; AVERSION; HALOTHANE; MIXTURES; BEHAVIOR;
D O I
10.2527/jas.2012-5761
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
The search for alternative methods to euthanize piglets is critical to address public concern that current methods are not optimal. Scientific evidence supports that blunt force trauma is humane when performed correctly, but most people find it visually difficult to accept. The use of CO2 is often recommended; at the same time, it is criticized as being aversive to pigs. This research sought to 1) identify a method of scientifically determining if piglets find a gas aversive, using an approach-avoidance test, which relies on the perspective of the piglet, and 2) test different gas mixtures to determine if they are effective and humane for neonatal piglet euthanasia. Pigs were allowed to walk freely between 1 chamber filled with air and another chamber either gradually filled with gas mixtures (Exp. 1) or prefilled with gas mixtures (Exp. 2). Experiment 1 tested CO2 (90%) and air (10%), N2O (60%) and CO2 (30%), Ar (60%) and CO2 (30%), and N-2 (60%) and CO2 (30%). Because piglets had to be removed when they started to flail, the test was shortest (P < 0.01) for the pigs in the CO2 treatment compared with pigs in the N2O/CO2, Ar/CO2, and N-2/CO2 treatments, 3.1 +/- 0.2, 8.5 +/- 0.6, 9.6 +/- 0.4, and 9.9 +/- 0.1 min, respectively. Nonetheless, all gas mixtures adversely affected the pigs, causing the pigs to leave the test chamber. In Exp. 2, piglets were allowed to enter a chamber prefilled with N-2/CO2 or N2O/CO2 (both 60/30%). Pigs exposed to the prefill chambers started to flail in fewer than 20 s, much faster in comparison with the gradual fill method, which supports that this method was more aversive. In Exp. 3, piglets were euthanized using a 2-step procedure. Pigs were first placed in a gradual fill chamber with 1 of 4 gas mixtures: 90% CO2, N-2/CO2, N2O/CO2, or N2O/O-2 (the last 3 mixtures at 60/30%) followed by placement into a 90% CO2 prefill chamber when the pigs started to flail or were anesthetized. All 3 gas treatments that contained CO2 killed pigs more quickly than N2O/O-2 (P < 0.05). However, N2O/O-2 was the only treatment that anesthetized the pigs instead of causing squeals or flailing although requiring about 12 min longer. Although longer, a 2-step procedure in which pigs are anesthetized with a mixture of N2O and O-2 before being euthanized by immersion in CO2 may prove to be more humane than CO2 alone.
引用
收藏
页码:1874 / 1883
页数:10
相关论文
共 50 条
  • [31] Evaluation of Carbon Dioxide Euthanasia of Female Sprague Dawley Rats Alone or With Unfamiliar Conspecifics
    Hickman, Debra L.
    JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2022, 61 (02): : 195 - 200
  • [32] Carbon dioxide for euthanasia: concerns regarding pain and distress, with special reference to mice and rats
    Conlee, KM
    Stephens, ML
    Rowan, AN
    King, LA
    LABORATORY ANIMALS, 2005, 39 (02) : 137 - 161
  • [33] Evaluating methods of gas euthanasia for laboratory mice
    Makowska, I. Joanna
    Vickers, Lori
    Mancell, Jane
    Weary, Daniel M.
    APPLIED ANIMAL BEHAVIOUR SCIENCE, 2009, 121 (3-4) : 230 - 235
  • [34] Swine respiratory disease minimally affects responses of nursery pigs to gas euthanasia
    Sadler, Larry J.
    Karriker, Locke A.
    Johnson, Anna K.
    Schwartz, Kent J.
    Widowski, Tina M.
    Wang, Chong
    Millman, Suzanne T.
    JOURNAL OF SWINE HEALTH AND PRODUCTION, 2014, 22 (03): : 125 - 133
  • [35] Behavioral Response of Weaned Pigs during Gas Euthanasia with CO2, CO2 with Butorphanol, or Nitrous Oxide
    Cavusoglu, Enver
    Rault, Jean-Loup
    Gates, Richard
    Lay, Donald C.
    ANIMALS, 2020, 10 (05):
  • [36] Gas killing of rats: the effect of supplemental oxygen on aversion to carbon dioxide
    Kirkden, R. D.
    Niel, L.
    Stewart, S. A.
    Weary, D. M.
    ANIMAL WELFARE, 2008, 17 (01) : 79 - 87
  • [37] Testing three measures of mouse insensibility following induction with isoflurane or carbon dioxide gas for a more humane euthanasia
    Moody, Carly M.
    Makowska, I. Joanna
    Weary, Daniel M.
    APPLIED ANIMAL BEHAVIOUR SCIENCE, 2015, 163 : 183 - 187
  • [38] Behavioural responses of rats to gradual-fill carbon dioxide euthanasia and reduced oxygen concentrations
    Niel, Lee
    Weary, Daniel M.
    APPLIED ANIMAL BEHAVIOUR SCIENCE, 2006, 100 (3-4) : 295 - 308
  • [39] Cardiovascular and Metabolic Responses to Carbon Dioxide Euthanasia in Conscious and Anesthetized Rats
    Nichols, Kathryn E.
    Holliday-White, Kimberly L.
    Bogie, Heather M.
    Swearingen, Kim M.
    Fine, Megan S.
    Doyle, Jennifer
    Tiesma, Scott R.
    JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2020, 59 (06): : 742 - 749
  • [40] Evaluation of Different Gases and Gas Combinations for On-Farm Euthanasia of Pre-Weaned Pigs
    Kells, Nikki
    Beausoleil, Ngaio
    Johnson, Craig
    Sutherland, Mhairi
    ANIMALS, 2018, 8 (03):