Turbo Spin-Echo Diffusion-Weighted Imaging in Prostate Magnetic Resonance Imaging of Men With Pelvic Hardware

被引:9
作者
Pirasteh, Ali [1 ,2 ,3 ]
Johnson, Brian [3 ,4 ]
Dimitrov, Ivan E. [3 ,4 ]
Costa, Daniel N. [3 ,5 ]
de Leon, Alberto Diaz [3 ]
Xi, Yin [3 ]
Madhuranthakam, Ananth J. [3 ,5 ]
Pedrosa, Ivan [3 ,6 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Med Phys, 1530 Med Sci Ctr, Madison, WI 53706 USA
[3] Univ Texas Southwestern Med Ctr Dallas, Dept Radiol, 2201 Inwood Rd,2nd Floor,Suite 202, Dallas, TX 75390 USA
[4] Philips Healthcare, Gainesville, FL USA
[5] Univ Texas Southwestern Med Ctr Dallas, Adv Imaging Res Ctr, Dallas, TX 75390 USA
[6] Univ Texas Southwestern Med Ctr Dallas, Dept Urol, Dallas, TX 75390 USA
关键词
multiparametric magnetic resonance imaging; diffusion weighted imaging; prostate cancer; SPLICE; metal-associated artifact; PRIOR NEGATIVE BIOPSY; TOTAL HIP; REPLACEMENT; DISTORTION; DIAGNOSIS; ARTIFACT; FUSION; DWI;
D O I
10.1097/RCT.0000000000001067
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We evaluated an alternative diffusion-weighted imaging (DWI) acquisition for prostate magnetic resonance imaging of men with pelvic hardware, using radialk-space sampling (MultiVane [MV]), short-tau inversion-recovery (STIR) fat suppression, and split acquisition of turbo spin-echo signals. The optimized STIR-MV-DWI reduced metal-associated artifacts and image distortion, and aided in visualization of the prostate and lesions. The STIR-MV-DWI can be a valuable adjunct in prostate magnetic resonance imaging of men with pelvic hardware, among whom the conventional echo-planar DWI is compromised.
引用
收藏
页码:519 / 526
页数:8
相关论文
共 28 条
[1]  
Akamine Y, 2018, REDUCED DISTORTION P
[2]   Phase insensitive preparation of single-shot RARE: Application to diffusion imaging in humans [J].
Alsop, DC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) :527-533
[3]   Diffusion-weighted imaging in the assessment of prostate cancer: Comparison of zoomed imaging and conventional technique [J].
Brendle, Cornelia ;
Martirosian, Petros ;
Schwenzer, Nina F. ;
Kaufmann, Sascha ;
Kruck, Stephan ;
Kramer, Ulrich ;
Notohamiprodjo, Mike ;
Nikolaou, Konstantin ;
Schraml, Christina .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (05) :893-900
[4]   Role of PROPELLER-DWI of the prostate in reducing distortion and artefact from total hip replacement metalwork [J].
Czarniecki, Marcin ;
Caglic, Iztok ;
Grist, James T. ;
Gill, Andrew B. ;
Lorenc, Kamil ;
Slough, Rhys A. ;
Priest, Andrew N. ;
Barrett, Tristan .
EUROPEAN JOURNAL OF RADIOLOGY, 2018, 102 :213-219
[5]   Multishot diffusion-weighted PROPELLER magnetic resonance imaging of the abdomen [J].
Deng, Jie ;
Miller, Frank H. ;
Salem, Riad ;
Omary, Reed A. ;
Larson, Andrew C. .
INVESTIGATIVE RADIOLOGY, 2006, 41 (10) :769-775
[6]   Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters [J].
Dietrich, Olaf ;
Raya, Jose G. ;
Reeder, Scott B. ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) :375-385
[7]   Geometric Distortion in Diffusion-weighted MR Imaging of the Prostate-Contributing Factors and Strategies for Improvement [J].
Donato, Francisco, Jr. ;
Costa, Daniel N. ;
Yuan, Qing ;
Rofsky, Neil M. ;
Lenkinski, Robert E. ;
Pedrosa, Ivan .
ACADEMIC RADIOLOGY, 2014, 21 (06) :817-823
[8]   The 2014 International Society of Urological Pathology (ISUP) Consensus Conference on Gleason Grading of Prostatic Carcinoma Definition of Grading Patterns and Proposal for a New Grading System [J].
Epstein, Jonathan I. ;
Egevad, Lars ;
Amin, Mahul B. ;
Delahunt, Brett ;
Srigley, John R. ;
Humphrey, Peter A. .
AMERICAN JOURNAL OF SURGICAL PATHOLOGY, 2016, 40 (02) :244-252
[9]   MRI-Targeted or Standard Biopsy for Prostate-Cancer Diagnosis [J].
Kasivisvanathan, V ;
Rannikko, A. S. ;
Borghi, M. ;
Panebianco, V ;
Mynderse, L. A. ;
Vaarala, M. H. ;
Briganti, A. ;
Budaus, L. ;
Hellawell, G. ;
Hindley, R. G. ;
Roobol, M. J. ;
Eggener, S. ;
Ghei, M. ;
Villers, A. ;
Bladou, F. ;
Villeirs, G. M. ;
Virdi, J. ;
Boxler, S. ;
Robert, G. ;
Singh, P. B. ;
Venderink, W. ;
Hadaschik, B. A. ;
Ruffion, A. ;
Hu, J. C. ;
Margolis, D. ;
Crouzet, S. ;
Klotz, L. ;
Taneja, S. S. ;
Pinto, P. ;
Gill, I ;
Allen, C. ;
Giganti, F. ;
Freeman, A. ;
Morris, S. ;
Punwani, S. ;
Williams, N. R. ;
Brew-Graves, C. ;
Deeks, J. ;
Takwoingi, Y. ;
Emberton, M. ;
Moore, C. M. .
NEW ENGLAND JOURNAL OF MEDICINE, 2018, 378 (19) :1767-1777
[10]   Magnetic Resonance Imaging Near Metal Implants [J].
Koch, K. M. ;
Hargreaves, B. A. ;
Pauly, K. Butts ;
Chen, W. ;
Gold, G. E. ;
King, K. F. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (04) :773-787