Coronary arteries: Three-dimensional MR imaging with retrospective respiratory gating

被引:152
作者
Li, DB [1 ]
Kaushikkar, S [1 ]
Haacke, EM [1 ]
Woodard, PK [1 ]
Dhawale, PJ [1 ]
Kroeker, RM [1 ]
Laub, G [1 ]
Kuginuki, Y [1 ]
Gutierrez, FR [1 ]
机构
[1] SIEMENS AG, D-8520 ERLANGEN, GERMANY
关键词
coronary vessels; MR; magnetic resonance (IMR); artifact; magnetic resonance (MR); motion correction; tissue suppression; vascular studies;
D O I
10.1148/radiology.201.3.8939242
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Thin-section, three-dimensional (3D) gradient-echo magnetic resonance imaging of the coronary arteries was performed without and with retrospective respiratory gating in 12 healthy volunteers and one patient. In all examinations, results were improved with gating. In five of seven volunteer examinations, coronary artery delineation on images reconstructed by using the least-squares method for motion detection with navigator echoes was found to be equal to that obtained by using edge detection. Images in five other volunteers covered the entire heart with multiple overlapping 3D slabs. The arteries were segmented from the background and could be viewed from any orientation. The lengths of contiguously visible vessels were as follows: left main coronary artery (11.5 mm +/- 0.4 (mean +/- standard deviation); left anterior descending branch, 115.9 mm +/- 19.7; left circumflex branch, 97.2 mm +/- 12.5; and right coronary artery, 125.9 mm +/- 18.8. This respiratory gating technique clearly improved depiction of the coronary arteries.
引用
收藏
页码:857 / 863
页数:7
相关论文
共 40 条
  • [1] RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING
    BAILES, DR
    GILDERDALE, DJ
    BYDDER, GM
    COLLINS, AG
    FIRMIN, DN
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) : 835 - 838
  • [2] CORONARY-ARTERY IMAGING IN MULTIPLE 1-SEC BREATH HOLDS
    DOYLE, M
    SCHEIDEGGER, MB
    DEGRAAF, RG
    VERMEULEN, J
    POHOST, GM
    [J]. MAGNETIC RESONANCE IMAGING, 1993, 11 (01) : 3 - 6
  • [3] 2-DIMENSIONAL CORONARY MR-ANGIOGRAPHY - ANALYSIS OF INITIAL CLINICAL-RESULTS
    DUERINCKX, AJ
    URMAN, MK
    [J]. RADIOLOGY, 1994, 193 (03) : 731 - 738
  • [4] HUMAN CORONARY-ARTERIES - PROJECTION ANGIOGRAMS RECONSTRUCTED FROM BREATH-HOLD 2-DIMENSIONAL MR IMAGES
    EDELMAN, RR
    MANNING, WJ
    PEARLMAN, J
    LI, W
    [J]. RADIOLOGY, 1993, 187 (03) : 719 - 722
  • [5] CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY
    EDELMAN, RR
    MANNING, WJ
    BURSTEIN, D
    PAULIN, S
    [J]. RADIOLOGY, 1991, 181 (03) : 641 - 643
  • [6] MAGNETIC-RESONANCE IMAGING WITH RESPIRATORY GATING - TECHNIQUES AND ADVANTAGES
    EHMAN, RL
    MCNAMARA, MT
    PALLACK, M
    HRICAK, H
    HIGGINS, CB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) : 1175 - 1182
  • [7] ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES
    EHMAN, RL
    FELMLEE, JP
    [J]. RADIOLOGY, 1989, 173 (01) : 255 - 263
  • [8] ADAPTIVE MOTION COMPENSATION IN MR IMAGING WITHOUT USE OF NAVIGATOR ECHOES
    FELMLEE, JP
    EHMAN, RL
    RIEDERER, SJ
    KORIN, HW
    [J]. RADIOLOGY, 1991, 179 (01) : 139 - 142
  • [9] ADAPTIVE MOTION COMPENSATION IN MRI - ACCURACY OF MOTION MEASUREMENT
    FELMLEE, JP
    EHMAN, RL
    RIEDERER, SJ
    KORIN, HW
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (01) : 207 - 213
  • [10] HAACKE E M, 1986, Magnetic Resonance Imaging, V4, P359, DOI 10.1016/0730-725X(86)91046-5