摘要
Some alkylsilica columns carry a positive charge at low pH, as determined by anion-exchange with nitrate ion. In the present study, the relative positive charge for 14 alkylsilica columns was measured for a mobile-phase pH 3.0. All but 3 of these columns were found to carry a significant positive charge under these conditions. The relative positive charge on these columns was found to correlate approximately with two other column characteristics: relative cation-exchange behavior as measured by the hydrophobic-subtraction model (values of C-2.8), and slow equilibration of the column to changes in the mobile-phase-as evidenced by a slow change in the retention of anionic and cationic solutes with time. The origin of this positive charge may arise from the bonding process, with incorporation of some cationic entity into the stationary phase. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:104 / 110
页数:7
相关论文
共 12 条
[1]   Characterization of the acidity of residual silanol groups in microparticulate and monolithic reversed-phase columns [J].
Herrero-Martínez, JM ;
Méndez, A ;
Bosch, E ;
Rosés, M .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1060 (1-2) :135-145
[2]   Evaluating the surface charge of C18 stationary phases [J].
Loeser, Eric .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (01) :45-52
[3]   Investigation of anion retention and cation exclusion effects for several C18 stationary phases [J].
Loeser, Eric ;
Drumm, Patrick .
ANALYTICAL CHEMISTRY, 2007, 79 (14) :5382-5391
[4]   Characterization and applications of reversed-phase column selectivity based on the hydrophobic-subtraction model [J].
Marchand, D. H. ;
Snyder, L. R. ;
Dolan, J. W. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1191 (1-2) :2-20
[5]   Slow equilibration of reversed-phase columns for the separation of ionized solutes [J].
Marchand, DH ;
Williams, LA ;
Dolan, JW ;
Snyder, LR .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1015 (1-2) :53-64
[6]   Overload for ionized solutes in reversed-phase high-performance liquid chromatography [J].
McCalley, DV .
ANALYTICAL CHEMISTRY, 2006, 78 (08) :2532-2538
[7]   Rationalization of retention and overloading behavior of basic compounds in reversed-phase HPLC using low ionic strength buffers suitable for mass spectrometric detection [J].
McCalley, DV .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3404-3410
[8]   Comparison of the acidity of residual silanol groups in several liquid chromatography columns [J].
Méndez, A ;
Bosch, E ;
Rosés, M ;
Neue, UD .
JOURNAL OF CHROMATOGRAPHY A, 2003, 986 (01) :33-44
[9]  
NEUE UD, COMMUNICATION
[10]  
Snyder L.R., 2007, ANAL CHEM, V79, P3255