Clinical utility of single-operator cholangiopancreatoscopy using a SpyGlass probe through an endoscopic retrograde cholangiopancreatography catheter

被引:20
|
作者
Kawakubo, Kazumichi [1 ]
Isayama, Hiroyuki [1 ]
Sasahira, Naoki [1 ]
Kogure, Hirofumi [1 ]
Takahara, Naminatsu [1 ]
Miyabayashi, Koji [1 ]
Mizuno, Suguru [1 ]
Yamamoto, Keisuke [1 ]
Mohri, Dai [1 ]
Sasaki, Takashi [1 ]
Yamamoto, Natsuyo [1 ]
Nakai, Yousuke [1 ]
Hirano, Kenji [1 ]
Tada, Minoru [1 ]
Koike, Kazuhiko [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Bunkyo Ku, Tokyo 1138655, Japan
关键词
cholangiopancreatoscopy; endoscopic retrograde cholangiopancreatography; SpyGlass probe; BILE-DUCT STONES; PERORAL CHOLANGIOSCOPY; MANAGEMENT; ERCP; COMPLICATIONS; DIAGNOSIS; THERAPY; LESIONS; VIDEOS;
D O I
10.1111/j.1440-1746.2012.07133.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aim: A single-operator cholangiopancreatoscopy was developed to overcome a problem in conventional peroral cholangiopancreatoscopy. The aim of this pilot study was to clarify the clinical utility of single-operator cholangiopancreatoscopy using a SpyGlass probe through an endoscopic retrograde cholangiopancreatography (ERCP) catheter. Methods: Patients undergoing ERCP with a SpyGlass probe passed through a catheter were included in this study. The SpyGlass probe was inserted into the catheter following successful cannulation, and cholangiopancreatoscopy was performed by a single operator. We retrospectively analyzed the successful visualization rate of this technique. Results: Fifteen patients were included in this study. SpyGlass cholangiopancreatoscopy was technically successful in all patients. Successful visualization was obtained in nine patients (60%). The median SpyGlass procedure time was 10 min. Cholangiopancreatoscopic diagnoses were as follows: bile duct carcinoma in three patients; intraductal papillary mucinous adenoma in two; and intraductal pancreatic stone, benign biliary stricture, gallbladder cholesterolosis, and gallbladder carcinoma in one each. There were no cases of post-ERCP pancreatitis. Conclusions: While the low rate of successful visualization must be improved, single-operator cholangiopancreatoscopy using a SpyGlass probe through an ERCP catheter is a safe and effective procedure.
引用
收藏
页码:1371 / +
页数:6
相关论文
共 35 条
  • [1] Evaluation of the effectiveness and safety of single-operator cholangiopancreatoscopy with the SpyGlass™ system
    Tejido, Coral
    Puga, Manuel
    Regueiro, Cristina
    Francisco, Maria
    Rivas, Laura
    Sanchez, Eloy
    Tm, Spyglass
    GASTROENTEROLOGIA Y HEPATOLOGIA, 2024, 47 (02): : 170 - 178
  • [2] The clinical value of ERCP-guided cholangiopancreatoscopy using a single-operator system
    Reuterwall, Marcus
    Lubbe, Jeanne
    Enochsson, Lars
    Lundell, Lars
    Konradsson, Magnus
    Swahn, Frederik
    Del Chiaro, Marco
    Lohr, Matthias
    Arnelo, Urban
    BMC GASTROENTEROLOGY, 2019, 19 (1)
  • [3] Single-Operator Wire-Guided Cannulation Technique for Endoscopic Retrograde Cholangiopancreatography
    Wang, Bin
    Chen, Yangrong
    Zhang, Shumin
    MEDICAL SCIENCE MONITOR, 2019, 25 : 6391 - 6396
  • [4] The clinical value of ERCP-guided cholangiopancreatoscopy using a single-operator system
    Marcus Reuterwall
    Jeanne Lubbe
    Lars Enochsson
    Lars Lundell
    Magnus Konradsson
    Frederik Swahn
    Marco Del Chiaro
    Matthias Löhr
    Urban Arnelo
    BMC Gastroenterology, 19
  • [5] Single-operator cholangiopancreatoscopy in pancreatobiliary diseases: clinical experience in a tertiary referral hospital
    Pons-Beltran, Vicente
    Alonso-Lazaro, Noelia
    Mansilla-Vivar, Rodrigo
    Saez-Gonzalez, Esteban
    Ponce-Romero, Marta
    Arguello-Viudez, Lidia
    Ramos-Soler, David
    Perez-Rojas, Judith
    Leathers, James
    Bustamante-Balen, Marco
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2018, 110 (12) : 748 - 754
  • [6] Clinical application of a single-operator direct visualization system improves the diagnostic and therapeutic yield of endoscopic retrograde cholangiopancreatography
    AlAmeel, Turki
    Bain, Vincent
    Sandha, Gurpal
    CANADIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2013, 27 (01) : 15 - 19
  • [7] Single-Operator Wire-Guided Cannulation Technique Enables Easier Cannulation of Endoscopic Retrograde Cholangiopancreatography
    Li, Qi-Yong
    Pan, Lelin
    Ling, Qi
    He, Jian-Di
    Zhang, Li-Xia
    Zheng, Shu-Sen
    DIGESTIVE DISEASES AND SCIENCES, 2012, 57 (12) : 3293 - 3298
  • [8] Single-Operator Wire-Guided Cannulation Technique Enables Easier Cannulation of Endoscopic Retrograde Cholangiopancreatography
    Qi-Yong Li
    Lelin Pan
    Qi Ling
    Jian-Di He
    Li-Xia Zhang
    Shu-Sen Zheng
    Digestive Diseases and Sciences, 2012, 57 : 3293 - 3298
  • [9] Digital, single-operator cholangiopancreatoscopy in the diagnosis and management of pancreatobiliary disorders: a multicenter clinical experience (with video)
    Navaneethan, Udayakumar
    Hasan, Muhammad K.
    Kommaraju, Kiran
    Zhu, Xiang
    Hebert-Magee, Shantel
    Hawes, Robert H.
    Vargo, John J.
    Varadarajulu, Shyam
    Parsi, Mansour A.
    GASTROINTESTINAL ENDOSCOPY, 2016, 84 (04) : 649 - 655
  • [10] Digital single-operator cholangioscope for endoscopic retrograde appendicitis therapy
    Kong, Ling-Jian
    Liu, Dan
    Zhang, Ji-Yu
    Ullah, Saif
    Zhao, Lixia
    Li, Deliang
    Yang, Huiyu
    Liu, Bing-Rong
    ENDOSCOPY, 2022, 54 (04) : 396 - 400