Error Mechanisms of the Oscillometric Fixed-Ratio Blood Pressure Measurement Method

被引:48
作者
Liu, Jiankun [1 ]
Hahn, Jin-Oh [2 ]
Mukkamala, Ramakrishna [1 ]
机构
[1] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[2] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
基金
加拿大自然科学与工程研究理事会; 美国国家科学基金会;
关键词
Arm cuff; Mathematical model; Non-invasive blood pressure monitoring; Oscillometry; Sensitivity analysis; EUROPEAN-SOCIETY; PREECLAMPSIA; PROTOCOL; ACCURACY; MAXIMUM;
D O I
10.1007/s10439-012-0700-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The oscillometric fixed-ratio method is widely employed for non-invasive measurement of systolic and diastolic pressures (SP and DP) but is heuristic and prone to error. We investigated the accuracy of this method using an established mathematical model of oscillometry. First, to determine which factors materially affect the errors of the method, we applied a thorough parametric sensitivity analysis to the model. Then, to assess the impact of the significant parameters, we examined the errors over a physiologically relevant range of those parameters. The main findings of this model-based error analysis of the fixed-ratio method are that: (1) SP and DP errors drastically increase as the brachial artery stiffens over the zero trans-mural pressure regime; (2) SP and DP become overestimated and underestimated, respectively, as pulse pressure (PP) declines; (3) the impact of PP on SP and DP errors is more obvious as the brachial artery stiffens over the zero trans-mural pressure regime; and (4) SP and DP errors can be as large as 58 mmHg. Our final and main contribution is a comprehensive explanation of the mechanisms for these errors. This study may have important implications when using the fixed-ratio method, particularly in subjects with arterial disease.
引用
收藏
页码:587 / 597
页数:11
相关论文
共 15 条
  • [1] Validation of the Omron MX3 Plus oscillometric blood pressure monitoring device according to the European Society of Hypertension international protocol
    Coleman, A
    Freeman, P
    Steel, S
    Shennan, A
    [J]. BLOOD PRESSURE MONITORING, 2005, 10 (03) : 165 - 168
  • [2] Cristalli C., 1995, Measurement, V14, P229, DOI 10.1016/0263-2241(94)00029-7
  • [3] Accuracy of inflationary versus deflationary oscillometry in pregnancy and preeclampsia: OMRON-MIT versus OMRON-M7
    de Greeff, Annemarie
    Beg, Zara
    Gangji, Zahra
    Dorney, Edwina
    Shennan, Andrew H.
    [J]. BLOOD PRESSURE MONITORING, 2009, 14 (01) : 37 - 40
  • [4] THEORY OF THE OSCILLOMETRIC MAXIMUM AND THE SYSTOLIC AND DIASTOLIC DETECTION RATIOS
    DRZEWIECKI, G
    HOOD, R
    APPLE, H
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1994, 22 (01) : 88 - 96
  • [5] CHARACTERIZATION OF THE OSCILLOMETRIC METHOD FOR MEASURING INDIRECT BLOOD-PRESSURE
    GEDDES, LA
    VOELZ, M
    COMBS, C
    REINER, D
    BABBS, CF
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1982, 10 (06) : 271 - 280
  • [6] Maternal arterial stiffness in pregnancies affected by preeclampsia
    Kaihura, Christina
    Savvidou, Makrina D.
    Anderson, James M.
    McEniery, Carmel M.
    Nicolaides, Kypros H.
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2009, 297 (02): : H759 - H764
  • [7] Performance of the UA-787 oscillometric blood pressure monitor according to the European Society of Hypertension protocol
    Longo, D
    Toffanin, G
    Garbelotto, R
    Zaetta, V
    Businaro, L
    Palatini, P
    [J]. BLOOD PRESSURE MONITORING, 2003, 8 (02) : 91 - 95
  • [8] Marey EJ., 1879, PHVSIOLOGIE EXPERIME, V2, P307
  • [9] MEANING OF THE POINT OF MAXIMUM OSCILLATIONS IN CUFF PRESSURE IN THE INDIRECT MEASUREMENT OF BLOOD-PRESSURE .2.
    MAUCK, GW
    SMITH, CR
    GEDDES, LA
    BOURLAND, JD
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1980, 102 (01): : 28 - 33
  • [10] Errors of oscillometric blood pressure measurement as predicted by simulation
    Raamat, Rein
    Talts, Jaak
    Jagomaegi, Kersti
    Kivastik, Jana
    [J]. BLOOD PRESSURE MONITORING, 2011, 16 (05) : 238 - 245