Highly sensitive and simultaneous electrochemical determinations of non-steroidal anti-inflammatory drugs in water using nanostructured carbon-based paste electrodes

被引:11
作者
Motoc, Sorina [1 ]
Manea, Florica [2 ]
Baciu, Anamaria [2 ]
Vasilie, Sergiu [2 ]
Pop, Aniela [2 ]
机构
[1] Romanian Acad, Coriolan Dragulescu Inst Chem, 24 Mihai Viteazu Bvd, Timisoara 300223, Romania
[2] Politehn Univ Timisoara, Dept Appl Chem & Engn Inorgan Cpds & Environm, 6 Bv V Parvan, Timisoara 300223, Romania
关键词
Anti-inflammatory drugs; Simultaneous electrodetection; Nanostructured carbon; Diclofenac; Naproxen; Ibuprofen; SOLID-PHASE EXTRACTION; WASTE-WATER; VOLTAMMETRIC DETERMINATION; IBUPROFEN; DICLOFENAC; NAPROXEN; PHARMACEUTICALS; NANOTUBES; SAMPLES; SURFACE;
D O I
10.1016/j.scitotenv.2022.157412
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Simple and fast simultaneous quantifications in water of anti-inflammatory drugs, which belong to the emerging pollutants, represents a great challenge for water quality control. The development of electrochemical methods to meet the simultaneous and concomitant detection requirements depends mainly on the electrode material. The fullerene-carbon nanofiber (FULL/CNF) and graphene-carbon nanotubes (GR/CNT) paste electrodes as sensing elements were employed for the first time for the determination of diclofenac (DCF), naproxen (NPX) and ibuprofen (IBP) simultaneously and concomitantly. The comparative morphostructural and electrochemical characterizations of both electrodes were achieved by scanning electron microscopy (SEM) and cyclic voltammetry (CV). Differential-pulsed voltammetry (DPV), chronoamperometry (CA) and multiple-pulsed amperometry (MPA) were used for detection tests. FULL/CNE electrode was suitable to develop a simultaneous DPV-based detection methodology that allowed reaching the lowest limit of detections of 0.230 nM for DCF, 0.310 nM for NPX and 0.180 nM for IBP. GR/CNT electrode did not provide stability for DPV-based detection, but the lowest limits of detection of 0.149 nM for DCF, 0.809 nM for NPX and 0.640 nM for IBP were achieved by MPA-based methodology. Both electrodes, linked to specific detection technique, showed good reproducibility, stability and ability to measure DCF, NPX and IBP simultaneously in aqueous solution. The satisfactory results achieved by analysis of real surface water sample (Bega River, Tim isoara city, Romania) indicated that the proposed voltammetric and amperometric methodologies using both electrodes have great potential for practical applications in analysis of different water samples.
引用
收藏
页数:9
相关论文
共 48 条
[31]   Electrochemical detection and degradation of ibuprofen from water on multi-walled carbon nanotubes-epoxy composite electrode [J].
Motoc, Sorina ;
Remes, Adriana ;
Pop, Aniela ;
Manea, Florica ;
Schoonman, Joop .
JOURNAL OF ENVIRONMENTAL SCIENCES, 2013, 25 (04) :838-847
[32]   Carbon-Based Nanomaterials/Allotropes: A Glimpse of Their Synthesis, Properties and Some Applications [J].
Nasir, Salisu ;
Hussein, Mohd Zobir ;
Zainal, Zulkarnain ;
Yusof, Nor Azah .
MATERIALS, 2018, 11 (02)
[33]   Graphene Oxide Electroreduced onto Boron-Doped Diamond and Electrodecorated with Silver (Ag/GO/BDD) Electrode for Tetracycline Detection in Aqueous Solution [J].
Negrea, Sorina ;
Diaconu, Lidia Ani ;
Nicorescu, Valeria ;
Motoc , Sorina ;
Orha, Corina ;
Manea, Florica .
NANOMATERIALS, 2021, 11 (06)
[34]  
O'Flynn D, 2021, ANAL METHODS-UK, V13, P575, DOI [10.1039/D0AY02098B, 10.1039/d0ay02098b]
[35]   Simultaneous determination of human pharmaceuticals in water samples by solid phase extraction and HPLC with UV-fluorescence detection [J].
Patrolecco, Luisa ;
Ademollo, Nicoletta ;
Grenni, Paola ;
Tolomei, Antonella ;
Caracciolo, Anna Barra ;
Capri, Silvio .
MICROCHEMICAL JOURNAL, 2013, 107 :165-171
[36]  
Plach Janina M., 2018, J MARKETING RES, V47, P96, DOI [10.2134/jeq2017.06.0234, DOI 10.1509/JMR.11.0203]
[37]  
Saleh T, 2016, Bioenergetics, V5, P1, DOI [10.4172/2167-7662.1000226, DOI 10.4172/2167-7662.1000226]
[38]  
Saleh Tawfik A, 2016, BIOENERGETICS OPEN A, V5, DOI [10.4172/2167-7662.1000226, DOI 10.4172/2167-7662.1000226]
[39]   Numerical Modeling of ECE-ECE and parallel EE-EE mechanisms in cyclic voltammetry. Reduction of 1,4-benzenedisulfonyl difluoride and 1,4-naphthalenedisulfonyl difluoride [J].
Sanecki, P ;
Skital, P ;
Kaczmarski, K .
ELECTROANALYSIS, 2006, 18 (10) :981-991
[40]   Simultaneous determination of pharmaceutically active compounds in wastewater samples by solid phase extraction and high-performance liquid chromatography with diode array and fluorescence detectors [J].
Santos, JL ;
Aparicio, I ;
Alonso, E ;
Callejón, M .
ANALYTICA CHIMICA ACTA, 2005, 550 (1-2) :116-122