A Numerical Analysis on a Solar Chimney with an Integrated Latent Heat Thermal Energy Storage

被引:2
|
作者
Buonomo, Bernardo [1 ]
Capasso, Lucia [1 ]
Diana, Alessandra [1 ]
Manca, Oronzio [1 ]
Nardini, Sergio [1 ]
机构
[1] Univ Campania Luigi Vanvitelli, Dip Ingn Ind & Informaz, Real Casa Annunziata, Via Roma 29, I-81031 Aversa Ce, Italy
来源
74TH ATI NATIONAL CONGRESS: ENERGY CONVERSION: RESEARCH, INNOVATION AND DEVELOPMENT FOR INDUSTRY AND TERRITORIES | 2019年 / 2191卷
关键词
PHASE-CHANGE MATERIAL; PERFORMANCE; PCM; VENTILATION; PARAMETERS; SIMULATION; WALLBOARD; PLATE; FOAM;
D O I
10.1063/1.5138762
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Solar chimney is a solar system which is employed in several applications such as ventilation for thermal comfort, passive solar heating and cooling of buildings, solar energy drying, and electric power generation. It employs solar radiation to raise the temperature of the air and the buoyancy of warm air to accelerate the air stream flowing through the system. It is very important to evaluate the thermal and fluid dynamic behaviors to realize a correct design of the solar chimney also for the case with an integrated thermal energy storage system. It includes height, width and depth of cavity, type of glazing, type of absorber, and inclusion of insulation or thermal mass. Besides these system parameters, other factors such as the location, climate, and orientation can also affect its performance. In this paper, a two-dimensional numerical investigation on a prototypal solar chimney system integrated with an absorbing capacity wall in a south facade of a building is presented. The capacity wall is composed of a high absorbing plate and an assigned thickness of phase change material. The chimney consists of a converging channel with one vertical absorbing wall and the glass plate inclined of 2 with respect to the vertical. The chimney is 5.0 m high, with the channel height equal to 4.0 m, whereas the channel gap is at the inlet equal to 0.34 m and at the outlet it is 0.20 m. The thermal energy storage system is 4.0 high. The transient analysis is carried out on a two-dimensional model in airflow and the governing equations are given in terms of k-s turbulence model. The problem is solved by means of the commercial code Ansys-Fluent. The numerical analysis was intended to evaluate the thermal and fluid dynamic behavior of the solar chimney integrated with a latent thermal energy storage system. Results are given in terms of wall temperature distributions, air velocity and temperature fields and transversal profiles. Thermal and fluid dynamics behaviors are evaluated in order to have some indications to improve the energy conversion system.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Energy and exergy performance assessments for latent heat thermal energy storage systems
    Li, Gang
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 51 : 926 - 954
  • [42] Numerical evaluation of a triple concentric-tube latent heat thermal energy storage
    Basal, Birol
    Unal, Ahmet
    SOLAR ENERGY, 2013, 92 : 196 - 205
  • [43] Numerical Simulations of Latent Heat Thermal Energy Storage Utilizing Double Inclined Fin
    Saldi, Zaki S.
    Prabowo, Bayu
    Buana, Indra
    Diguna, Lina J.
    4TH INTERNATIONAL TROPICAL RENEWABLE ENERGY CONFERENCE (I-TREC 2019), 2020, 2255
  • [44] Thermal analysis of a rectangular latent heat storage unit with stearic acid/paraffin wax composite PCM for solar thermal energy storage systems
    Saini, Dinesh Kumar
    Muniyappa, Chandrashekara
    Yadav, Avadhesh
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2025, 47 (01) : 4279 - 4296
  • [45] Thermal hysteresis analysis of finned-heat-pipe-assisted latent heat thermal energy storage application for solar water heater system
    Bazri, Shahab
    Badruddin, Irfan Anjum
    Usmani, Abdullah Yousuf
    Khan, Saleem Anwar
    Kamangar, Sarfaraz
    Naghavi, Mohammad Sajad
    Mallah, Abdul Rahman
    Abdelrazek, Ali H.
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 40
  • [46] An analysis of a packed bed latent heat thermal energy storage system using PCM capsules: Numerical investigation
    Regin, A. Felix
    Solanki, S. C.
    Saini, J. S.
    RENEWABLE ENERGY, 2009, 34 (07) : 1765 - 1773
  • [47] Experimental and numerical study of latent heat thermal energy storage with high porosity metal matrix under intermittent heat loads
    Kumar, Ashish
    Saha, Sandip K.
    APPLIED ENERGY, 2020, 263
  • [48] Transient CFD Analysis of Macro-Encapsulated Latent Heat Thermal Energy Storage Containers Incorporated within Solar Air Heater
    Raj, Arun K.
    Srinivas, M.
    Jayaraj, S.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 156
  • [49] A Numerical Analysis of Latent Thermal Energy Storage for Refrigerated Trucks
    Calati, Michele
    Zilio, Claudio
    Righetti, Giulia
    Longo, Giovanni A.
    Hooman, Kamel
    Mancin, Simone
    13TH IIR CONFERENCE ON PHASE CHANGE MATERIALS AND SLURRIES FOR REFRIGERATION AND AIR CONDITIONING (PCM2021), 2021, : 369 - 376
  • [50] Melting dynamics analysis of a multi-tube latent heat thermal energy storage system: Numerical study
    Vikas
    Yadav, Ankit
    Samir, Sushant
    APPLIED THERMAL ENGINEERING, 2022, 214