Looking Inside Catalyst Extrudates with Time-Resolved Surface-Enhanced Raman Spectroscopy (TR-SERS)

被引:10
作者
Harvey, Clare E. [1 ]
Petterson, Ingeborg E. Iping [2 ]
Weckhuysen, Bert M. [1 ]
Gooijer, Cees [2 ]
Ariese, Freek [2 ]
Mank, Arjan J. G. [1 ,3 ]
机构
[1] Univ Utrecht, Debye Inst Nanomat Sci, NL-3584 CG Utrecht, Netherlands
[2] Vrije Univ Amsterdam, LaserLaB, NL-1081 HV Amsterdam, Netherlands
[3] Philips Innovat Serv, Dept Mol & Struct Anal, Eindhoven, Netherlands
关键词
Heterogeneous catalysis; Depth profiling; Time-resolved Raman spectroscopy; TRRS; Spatially offset Raman spectroscopy; SORS; Surface-enhanced Raman spectroscopy; SERS; SCATTERING; FLUORESCENCE; REJECTION; BODIES; SILVER;
D O I
10.1366/12-06698
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Raman spectroscopy is one of the major characterization methods employed over the last few decades as a nondestructive technique for the study of heterogeneous catalysts and related catalytic reactions. However, the promise of practical applicability on millimeter-sized catalyst bodies, such as extrudates, has not been fulfilled completely. Large fluorescence signals and the highly scattering nature of the extrudates often hamper its practical usage. Different approaches to overcome this problem were examined, including the use of time-resolved Raman spectroscopy (TRRS), spatially offset Raman spectroscopy (SORS), surface-enhanced Raman spectroscopy (SERS), and combinations of these techniques. This paper demonstrates that especially TRRS can provide chemical information at depth within catalyst bodies, overcoming fluorescence background signals and allowing for visualization of analytes at different depths. It also examines the application of time-resolved SERS within catalyst bodies to gain insight into localized activity. With these options a wider applicability of Raman spectroscopy for industrial catalysis research becomes within reach.
引用
收藏
页码:1179 / 1185
页数:7
相关论文
共 38 条
  • [1] Picosecond Raman spectroscopy with a fast intensified CCD camera for depth analysis of diffusely scattering media
    Ariese, Freek
    Meuzelaar, Heleen
    Kerssens, Marleen M.
    Buijs, Joost B.
    Gooijer, Cees
    [J]. ANALYST, 2009, 134 (06) : 1192 - 1197
  • [2] Operando methodology:: combination of in situ spectroscopy and simultaneous activity measurements under catalytic reaction conditions
    Bañares, MA
    [J]. CATALYSIS TODAY, 2005, 100 (1-2) : 71 - 77
  • [3] Mechanisms of catalyst deactivation
    Bartholomew, CH
    [J]. APPLIED CATALYSIS A-GENERAL, 2001, 212 (1-2) : 17 - 60
  • [4] Chemical imaging of catalytic solids with synchrotron radiation
    Beale, Andrew M.
    Jacques, Simon D. M.
    Weckhuysen, Bert M.
    [J]. CHEMICAL SOCIETY REVIEWS, 2010, 39 (12) : 4656 - 4672
  • [5] Looking on heterogeneous catalytic systems from different perspectives:: Multitechnique approaches as a new challenge for in situ studies
    Brückner, A
    [J]. CATALYSIS REVIEWS-SCIENCE AND ENGINEERING, 2003, 45 (01): : 97 - 150
  • [6] Combined time- and space-resolved Raman spectrometer for the non-invasive depth profiling of chemical hazards
    Cletus, Biju
    Olds, William
    Izake, Emad L.
    Sundarajoo, Shankaran
    Fredericks, Peter M.
    Jaatinen, Esa
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (01) : 255 - 263
  • [7] Dumesic J.A., 1997, HDB HETEROGENEOUS CA, P1
  • [8] Fluorescence rejection in resonance Raman spectroscopy using a picosecond-gated intensified charge-coupled device camera
    Efremov, Evtim V.
    Buijs, Joost B.
    Gooijer, Cees
    Ariese, Freek
    [J]. APPLIED SPECTROSCOPY, 2007, 61 (06) : 571 - 578
  • [9] Profiling Physicochemical Changes within Catalyst Bodies during Preparation: New Insights from Invasive and Noninvasive Microspectroscopic Studies
    Espinosa-Alonso, Leticia
    Beale, Andrew M.
    Weckhuysen, Bert M.
    [J]. ACCOUNTS OF CHEMICAL RESEARCH, 2010, 43 (09) : 1279 - 1288
  • [10] Photon migration in Raman spectroscopy
    Everall, N
    Hahn, T
    Matousek, P
    Parker, AW
    Towrie, M