First clinical experience of high-power ablation of atrial fibrillation with a novel contact force-sensing gold-tip catheter

被引:0
作者
Parwani, Abdul Shokor [1 ,2 ,3 ]
Jayanata, Adrian [1 ]
Kraft, Robin [1 ]
Lacour, Phillip [1 ,2 ]
Blaschke, Florian [1 ,2 ]
Pieske, Burkert [1 ,2 ]
Boldt, Leif-Hendrik [1 ,2 ]
机构
[1] Charite Univ med Berlin, Dept Internal Med & Cardiol, Campus Virchow Klinikum, Berlin, Germany
[2] DZHK German Ctr Cardiovasc Res, Partner site, Berlin, Germany
[3] Charite Univ med Berlin, Dept Internal Med & Cardiol, Campus Virchow Klinikum, Augustenburger Pl 1, D-13353 Berlin, Germany
关键词
ablation; high power; contact force sensing; atrial fibrillation; gold -tip catheter; PULMONARY VEIN ISOLATION; SAFETY;
D O I
10.5603/CJ.a2022.0060
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Contact force (CF)-sensing catheters are commonly used in the field of radiofrequency (RF) ablation to treat atrial fibrillation (AF). Increasing ablation power (e.g., 50 W) has been suggested as a method to reduce procedure times whilst creating safe and lasting lesions.Methods: We report the first clinical evidence of a 50 W point-by-point RF ablation in 25 consecutive patients with symptomatic AF using a novel CF-sensing catheter with a gold tip (AlCath Force, BIOTRONIK). We collected and analyzed procedural and ablation parameters. The safety and efficacy of the catheter were evaluated. Results: Altogether, 985 RF lesions in 25 patients were created with a mean number of 39.4 +/- 16.3 lesions per patient. The total skin-to-skin procedure time was 116.1 +/- 35.1 min, and the mean total area dose product was 10.9 +/- 5.1 Gy*cm2. The mean RF time per procedure was 13.2 +/- 6.6 min. The mean RF time per lesion was 20.2 +/- 8.4 s. The mean CF was 15.7 +/- 7.6 g. We observed a mean force time integral of 274.7 +/- 11.1 gs (range: 53 to 496 gs). Acute procedural success, defined as entrance and exit block in all pulmonary veins, could be obtained in all cases. No procedure- or device-related serious adverse events were observed. No audible steam pops occurred. Optical inspection of the catheter after the procedure showed neither charring nor clotting.Conclusions: We provide the first evidence for the safety and efficacy of 50 W ablation using the AlCath Force gold-tip catheter. These data must be supported by a larger multi-center study.
引用
收藏
页码:759 / 765
页数:7
相关论文
共 20 条
[1]   High-power short-duration versus standard radiofrequency ablation: Insights on lesion metrics [J].
Bourier, Felix ;
Duchateau, Josselin ;
Vlachos, Konstantinos ;
Lam, Anna ;
Martin, Claire A. ;
Takigawa, Masateru ;
Kitamura, Takeshi ;
Frontera, Antonio ;
Cheniti, Ghassen ;
Pambrun, Thomas ;
Klotz, Nicolas ;
Denis, Arnaud ;
Derval, Nicolas ;
Cochet, Hubert ;
Sacher, Frederic ;
Hocini, Meleze ;
Haissaguerre, Michel ;
Jais, Pierre .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (11) :1570-1575
[2]   Feasibility and safety of pulmonary vein isolation by high-power short-duration radiofrequency application: short-term results of the POWER-FAST PILOT study [J].
Castrejon-Castrejon, Sergio ;
Martinez Cossiani, Marcel ;
Ortega Molina, Marta ;
Escobar, Carlos ;
Froilan Torres, Consuelo ;
Gonzalo Bada, Nerea ;
Diaz de la Torre, Marta ;
Suarez Parga, Jose Manuel ;
Lopez Sendon, Jose Luis ;
Luis Merino, Jose .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 57 (01) :57-65
[3]   Catheter ablation for atrial fibrillation: results from the first European Snapshot Survey on Procedural Routines for Atrial Fibrillation Ablation (ESS-PRAFA) Part II [J].
Chen, Jian ;
Dagres, Nikolaos ;
Hocini, Melece ;
Fauchier, Laurent ;
Bongiorni, Maria Grazia ;
Defaye, Pascal ;
Hernandez-Madrid, Antonio ;
Estner, Heidi ;
Sciaraffia, Elena ;
Blomstrom-Lundqvist, Carina .
EUROPACE, 2015, 17 (11) :1727-1732
[4]   Low contact force and force-time integral predict early recovery and dormant conduction revealed by adenosine after pulmonary vein isolation [J].
de Waroux, Jean-Benoit le Polain ;
Weerasooriya, Rukshen ;
Anvardeen, Kalilur ;
Barbraud, Cynthia ;
Marchandise, Sebastien ;
De Meester, Christophe ;
Goesaert, Cedric ;
Reis, Ivone ;
Scavee, Christophe .
EUROPACE, 2015, 17 (06) :877-883
[5]   Updated Survey on Interventional Electrophysiology 5-Year Follow-Up of Infrastructure, Procedures, and Training Positions in Germany [J].
Eckardt, Lars ;
Frommeyer, Gerrit ;
Sommer, Philipp ;
Steven, Daniel ;
Deneke, Thomas ;
Estner, Heidi L. ;
Kriatselis, Charalampos ;
Kuniss, Malte ;
Busch, Sonia ;
Tilz, Roland R. ;
Bonnemeier, Hendrik ;
von Bary, Christian ;
Voss, Frederik ;
Meyer, Christian ;
Thomas, Dierk ;
Neuberger, Hans-Ruprecht .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (06) :820-827
[6]   Lesion size and adjacent tissue damage assessment with high power and short duration radiofrequency ablation: comparison to conventional radiofrequency ablation power setting [J].
Enomoto, Yoshinari ;
Nakamura, Keijiro ;
Ishii, Rina ;
Toyoda, Yasutake ;
Asami, Masako ;
Takagi, Takahito ;
Hashimoto, Hikari ;
Hara, Hidehiko ;
Sugi, Kaoru ;
Moroi, Masao ;
Nakamura, Masato .
HEART AND VESSELS, 2021, 36 (09) :1438-1444
[7]  
Healy SG, 2017, EUROPACE, V19, piii279, DOI [10.1093/ehjci/eux158.036, DOI 10.1093/EHJCI/EUX158.036]
[8]   Extent and magnitude of low-voltage areas assessed by ultra-high-density electroanatomical mapping correlate with left atrial function [J].
Hohendanner, F. ;
Romero, I ;
Blaschke, F. ;
Heinzel, F. R. ;
Pieske, B. ;
Boldt, L-H ;
Parwani, A. S. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 272 :108-112
[9]   Comparison of lesion formation between contact force-guided and non-guided circumferential pulmonary vein isolation: A prospective, randomized study [J].
Kimura, Masaomi ;
Sasaki, Shingo ;
Owada, Shingen ;
Horiuchi, Daisuke ;
Sasaki, Kenichi ;
Itoh, Taihei ;
Ishida, Yuji ;
Kinjo, Takahiko ;
Tomita, Hirofumi ;
Okumura, Ken .
HEART RHYTHM, 2014, 11 (06) :984-991
[10]   Safety and outcome of very if high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillation [J].
Kottmaier, Marc ;
Popa, Miruna ;
Bourier, Felix ;
Reents, Tilko ;
Cifuentes, Jairo ;
Semmler, Verena ;
Telishevska, Martha ;
Otgonbayar, Ulamnemekh ;
Koch-Buettner, Katharina ;
Lennerz, Carsten ;
Bartkowiak, Marcin ;
Kornmayer, Marielouise ;
Rousseva, Elena ;
Brkic, Amir ;
Grebmer, Christian ;
Kolb, Christoph ;
Hessling, Gabriele ;
Deisenhofer, Isabel .
EUROPACE, 2020, 22 (03) :388-393