Postbuckling Behavior of axially restrained and axially loaded steel columns under fire conditions

被引:65
作者
Wang, YC [1 ]
机构
[1] UMIST, Manchester Ctr Civil & Struct Engn, Manchester M60 1QD, Lancs, England
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 2004年 / 130卷 / 03期
关键词
postbuckling; axial loads; steel columns; fire hazards; temperature;
D O I
10.1061/(ASCE)0733-9445(2004)130:3(371)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of a theoretical study of the postbuckling behavior of an axially loaded steel column at elevated temperatures whose thermal expansion is restrained by the adjacent structural members. This study investigates the effects on the column failure temperature by various factors, including the restraint stiffness during the column loading (expansion) and unloading (contraction) phases, column slenderness, and the initially applied column load ratio. The column failure temperature is defined as the temperature at which the load in the column during the postbuckling phase returns to its initial load. Results of this study indicate that the column failure temperature can be much higher than that of the column at first buckling and the higher the column slenderness, the larger the difference between temperatures of column failure and first buckling. Consequently, the column postbuckling behavior should be considered. Nevertheless, for columns with light restraints (restraint stiffness to column stiffness less than 5%) or high load ratios (load ratio higher than 0.5), the failure temperature of the column with realistic unloading stiffness of the restraint is only slightly affected by the postbuckling behavior.
引用
收藏
页码:371 / 380
页数:10
相关论文
共 11 条
[1]  
*BRE, 1996, P 2 CARD C BEDF B EN
[2]  
*BSI, 1990, 5950 BSI
[3]  
*CEN, 2000, EUR, V3
[4]  
*CTICM, 1982, 3 BRE
[5]   Failure temperature of a system comprising a restrained column submitted to fire [J].
Franssen, JM .
FIRE SAFETY JOURNAL, 2000, 34 (02) :191-207
[6]   Experimental research on the critical temperature of compressed steel elements with restrained thermal elongation [J].
Rodrigues, JPC ;
Neves, IC ;
Valente, JC .
FIRE SAFETY JOURNAL, 2000, 35 (02) :77-98
[7]  
SIMMS WI, 1995, J APPL FIRE SCI, V5, P269
[8]   Stability of steel columns in case of fire: Numerical modeling [J].
Talamona, D ;
Franssen, JM ;
Schleich, JB ;
Kruppa, J .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1997, 123 (06) :713-720
[9]  
Wang Y., 1994, FIRE SAF SCI, V4, P1055, DOI 10.3801/iafss.fss.4-1055
[10]   The effects of frame continuity on the behaviour of steel columns under fire conditions and fire resistant design proposals [J].
Wang, YC .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1997, 41 (01) :93-111