Multicollector ICP-MS analysis of Pb isotopes using a 207pb-204pb double spike demonstrates up to 400 ppm/amu systematic errors in Tl-normalization

被引:283
作者
Thirlwall, MF [1 ]
机构
[1] Univ London, Royal Holloway & Bedford New Coll, Dept Geol, Egham TW20 0EX, Surrey, England
关键词
lead; mass bias; ICP-MS; isotopes; errors; TIMS;
D O I
10.1016/S0009-2541(01)00365-5
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Pb isotope analyses using multicollector magnetic sector inductively coupled plasma mass spectrometers (ICP-MS) may potentially be corrected for mass bias, a major source of uncertainty, by assuming that the mass bias for TI is similar to that of Pb. Around 7 ng of Pb has been analysed in this study using a Micromass IsoProbe MC-ICP-MS. With detailed attention to backgrounds arising from instrument memory and tailing from adjacent peaks, external precision of 55 -180 ppm 2sd has been achieved over a year on Pb isotope ratios normalized to constant Pb-208/Pb-206. This involves use of a wide range of SRM981 solutions and two different nebulizers. Mean ratios are very close to multidynamic TIMS data normalized in the same way, provided that anomalous TIMS behaviour of (207)pb [Chem. Geol. Isot. Geosci. Sect. 163 (2000) 2991 is corrected to the least fractionated ratios measured. Tl-normalized Pb isotope ratios vary substantially between different SRM981 solutions and between nebulizers, with external precision over the year being up to 541 ppm (2sd) on Pb-208/Pb-204. However, a (207)pb-(204)pb double spike (DS) can accurately correct for mass bias on the IsoProbe, and external precision of at worst 245 ppm (2sd) on Pb-208/Pb-204 has been obtained over the year using a wide range of SRM981 solutions and two different nebulizers. Mean ratios on DS-corrected SRM981 and silicate samples are within error of DS-TIMS results, even using an independent calibration for the DS on the IsoProbe. A new Pb-208/Pb-206 value for SRM981 of 2.1677+/-2 is proposed, normalized to SRM982 Pb-208/Pb-206=1.00016. Use of SRM981 to optimize the Tl-205/Tl-203 normalizing ratio would give Tl-normalized sample ratios similar to400 ppm/amu higher than those calculated using the DS correction. It is shown that these problems with TI normalization cannot result from isobaric interferences, but they appear to be due to unusual solution chemistry of TI in the nebulizer. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:255 / 279
页数:25
相关论文
共 21 条
[1]   Pb and Nd isotopes in NE Atlantic Fe-Mn crusts: Proxies for trace metal paleosources and paleocean circulation [J].
Abouchami, W ;
Galer, SJG ;
Koschinsky, A .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1999, 63 (10) :1489-1505
[2]   A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopes [J].
Belshaw, NS ;
Freedman, PA ;
O'Nions, RK ;
Frank, M ;
Guo, Y .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 181 :51-58
[3]   A THEORETICAL STUDY OF USE OF INTERNAL STANDARDS FOR PRECISE ISOTOPIC ANALYSIS BY SURFACE IONIZATION TECHNIQUE .1. GENERAL FIRST-ORDER ALGEBRAIC SOLUTIONS [J].
DODSON, MH .
JOURNAL OF SCIENTIFIC INSTRUMENTS, 1963, 40 (06) :289-&
[4]   Reevaluation of precise lead isotope measurements by thermal ionization mass spectrometry:: comparison with determinations by plasma source mass spectrometry [J].
Doucelance, R ;
Manhès, G .
CHEMICAL GEOLOGY, 2001, 176 (1-4) :361-377
[5]  
Galer S. J. G., 1998, MINERAL MAG A, V62, P491, DOI DOI 10.1180/MINMAG.1998.62A.1.260
[6]   Lead isotopic analyses of NIST standard reference materials using multiple collector inductively coupled plasma mass spectrometry coupled with a modified external correction method for mass discrimination effect [J].
Hirata, T .
ANALYST, 1996, 121 (10) :1407-1411
[7]   Correction of instrumentally produced mass fractionation during isotopic analysis of Fe by thermal ionization mass spectrometry [J].
Johnson, CM ;
Beard, BL .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1999, 193 (01) :87-99
[8]   DETERMINATION OF LEAD ISOTOPE RATIOS BY INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS) [J].
LONGERICH, HP ;
FRYER, BJ ;
STRONG, DF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) :39-48
[9]   Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometry [J].
Maréchal, CN ;
Télouk, P ;
Albarède, F .
CHEMICAL GEOLOGY, 1999, 156 (1-4) :251-273
[10]   Accuracy and long-term reproducibility of lead isotopic measurements by multiple-collector inductively coupled plasma mass spectrometry using an external method for correction of mass discrimination [J].
Rehkämper, M ;
Halliday, AN .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 181 :123-133