Test-Retest and Inter-Rater Reliability of Isokinetic Ankle Dorsiflexor and Plantar Flexor Strength Measurement in Healthy Adults

被引:8
作者
Ozyemisci Taskiran, Ozden [1 ]
Ozdodan, Vildan [1 ]
Sepici, Vesile [1 ]
Meray, Jale [1 ]
机构
[1] Gazi Univ, Fac Med, Dept Phys Med & Rehabil, Ankara, Turkey
来源
TURKIYE FIZIKSEL TIP VE REHABILITASYON DERGISI-TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION | 2013年 / 59卷 / 01期
关键词
Isokinetic measurement; reliability; ankle; dorsiflexion; plantar flexion; peak torque; MUSCLE STRENGTH;
D O I
10.4274/03264
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To determine the test-retest and inter-rater reliability of isokinetic strength measurements of ankle dorsiflexor and plantar flexors. Materials and Methods: Thirteen healthy subjects (mean age: 34.3 +/- 9.2 years; female/male: 11/2) were participated in the study. Isokinetic measurements of ankle dorsiflexion and plantar flexion were performed by the isokinetic dynamometer. The participants were tested at 30 degrees and 120 degrees/sec angular velocities while lying in prone position. Each subject was tested three times by two examiners. All the tests were performed at the same time period of the day. Results: Intraclass correlation coefficients for test-retest reliability ranged between 0.86 and 0.92 for isokinetic measurements of ankle plantar flexion and dorsiflexion at 30 degrees/sec and between 0.81 and 0.93 at 120 degrees/sec angular velocity. The ICC values for inter-rater reliability ranged between 0.81 and 0.93. Conclusion: Peak torque measurements of ankle dorsiflexors and plantar flexors at 30 and 120 sec angular velocities had a high intrarater and inter-rater reliability using the isokinetic dynamometer. Turk J Phys Med Rehab 2073;59:32-5.
引用
收藏
页码:32 / 35
页数:4
相关论文
共 15 条
[1]   Postural control in healthy individuals [J].
Clifford, Amanda Marie ;
Holder-Powell, Heather .
CLINICAL BIOMECHANICS, 2010, 25 (06) :546-551
[2]   Feedforward ankle strategy of balance during quiet stance in adults [J].
Gatev, P ;
Thomas, S ;
Kepple, T ;
Hallett, M .
JOURNAL OF PHYSIOLOGY-LONDON, 1999, 514 (03) :915-928
[3]  
Holmbäck AM, 1999, SCAND J REHABIL MED, V31, P229
[4]   Test-retest reliability of isokinetic muscle strength of the lower extremities in patients with stroke [J].
Hsu, AL ;
Tang, PF ;
Jan, MH .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (08) :1130-1137
[5]   Reliability of isokinetic strength imbalance ratios measured using the Cybex NORM dynamometer [J].
Impellizzeri, Franco M. ;
Bizzini, Mario ;
Rampinini, Ermanno ;
Cereda, Ferdinando ;
Maffiuletti, Nicola A. .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2008, 28 (02) :113-119
[6]   Reliability of isokinetic trunk muscle strength measurement [J].
Karatas, GK ;
Gögüs, F ;
Meray, J .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2002, 81 (02) :79-85
[7]  
Menz H B., J Gerontol A Biol Sci Med Sci
[8]   The reliability of isokinetic testing of the ankle joint and a heel-raise test for endurance [J].
Möller, M ;
Lind, K ;
Styf, J ;
Karlsson, J .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (01) :60-71
[9]   Strength, power output and symmetry of leg muscles: effect of age and history of falling [J].
Perry, Mark C. ;
Carville, Serena F. ;
Smith, I. Christopher H. ;
Rutherford, Olga M. ;
Newham, Di J. .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2007, 100 (05) :553-561
[10]   Fall risk assessment in very old males and females living in nursing homes [J].
Sieri, T ;
Beretta, G .
DISABILITY AND REHABILITATION, 2004, 26 (12) :718-723